Navegação por assunto "absorbed radiation doses"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 19817

    MOURA, E.S.; ZEITUNI, C.A. ; SAKURABA, R.K.; GONCALVES, V.D.; CRUZ, J.C.; JUNIOR, D.K.; SOUZA, C.D.; ROSTELATO, M.E.C.M. . Absorbed dose simulations in near-surface regions using high dose rate iridium-192 sources applied for brachytherapy. Radiation Physics and Chemistry, v. 95, p. 299-301, 2014.

    Palavras-Chave: absorbed radiation doses; beta particles; brachytherapy; cobalt 60; computerized simulation; depth dose distributions; iridium 192; mammary glands; monte carlo method; pmma; prostate; surfaces

    Icon

  • IPEN-DOC 19438

    OCAMPO, IVETTE Z.; OKAZAKI, KAYO ; VIEIRA, DANIEL P.. An improved in vitro micronucleus assay to biological dosimetry. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 11th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 18th; MEETING ON NUCLEAR INDUSTRY, 3rd, November 24-29, 2013, Recife, PE. Proceedings... Sao Paulo: ABEN, 2013, 2013.

    Palavras-Chave: absorbed radiation doses; biological radiation effects; chromosomal aberrations; cobalt 60; dna; fluorescence; in vitro; ionizing radiations; microscopy; nitric oxide; tumor cells

    Icon

  • IPEN-DOC 20909

    VIEIRA, S.L.; OLIVEIRA, L.N. de; SCHIMIDT, F.; ANTONIO, P.L. ; CALDAS, L.V.E. . Assessment of polybutadiene and polystyrene rubbers for medical-industrial high-dose radiation dosimetry - Preliminary study. In: ENCONTRO NACIONAL DE FISICA DA MATERIA CONDENSADA, 38., 24-28 de maio, 2015, Foz do Iguaçu, PR. Resumo... 2015.

    Palavras-Chave: polymers; butadiene; polystyrene; rubbers; medicine; industry; radiation doses; absorbed radiation doses; dosimetry

    Icon

  • IPEN-DOC 21092

    CARDOSO, JESSICA R. ; GABRIEL, LEANDRO ; GERALDO, AUREA B.C. ; MOURA, EDUARDO . Characteristics of recycled and electron beam irradiated high density polyethylene samples. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 12th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 19th; MEETING ON NUCLEAR INDUSTRY, 4th, October 4-9, 2015, São Paulo, SP. Proceedings... 2015.

    Palavras-Chave: electron beams; polyethylenes; infrared spectra; cross-linking; absorbed radiation doses; fourier transformation; mechanical properties; mechanical tests; thermal analysis

    Icon

  • IPEN-DOC 20925

    MOURA, EDUARDO S. . Desenvolvimento de um objeto simulador para investigação de heterogeneidades em braquiterapia de alta taxa de dose / Development of a phantom for investigations with heterogeneties in high-dose-rate brachytherapy . 2015. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 90 p. Orientador: Carlos Alberto Zeituni.

    Abstract: A braquiterapia de alta taxa de dose é uma das modalidades mais utilizadas em braquiterapia para o tratamento de câncer. Os diversos avanços tecnológicos, bem como a evolução das técnicas de tratamento tornaram a braquiterapia de alta taxa de dose uma das modalidades de estado da arte para o tratamento de alguns cânceres. Parte deste avanço é creditada à melhoria na acurácia e na prescrição de dose absorvida recomendada ao paciente, ao longo dos anos. Este avanço permite que atualmente seja possível realizar os cálculos dosimétricos, por meio de sistemas de planejamento computadorizado, considerando as heterogeneidades dos pacientes, tais como: tecidos e órgãos com composições diferentes da água (meio de referência em radioterapia), contorno do paciente individualizado, introdução de aplicadores, dentre outros. Tais avanços demandam o controle de qualidade destas ferramentas, com objetivo de assegurar que todo o processo de tratamento seja satisfatório e acurado. Até o momento, a comunidade carece de um sistema experimental capaz de avaliar, considerando os níveis de incerteza, se os sistemas de planejamento computadorizados são aptos a considerar a heterogeneidade dos tratamentos. Neste trabalho, apresentamos o desenvolvimento de medidas experimentais em um objeto simulador, com capacidade de mensurar as diferenças introduzidas pela heterogeneidade por meio de três técnicas dosimétricas experimentais: termoluminescência, filmes radiocrômicos e ionométrica. Os resultados experimentais foram comparados com as simulações de Monte Carlo e com um sistema de planejamento computadorizado comercial, apto a realizar correções de heterogeneidade em braquiterapia. Discutimos as principais etapas de desenvolvimento deste objeto simulador, seus resultados experimentais e as comparações com os demais sistemas. As conclusões e as etapas futuras deste projeto também são apresentadas.

    Palavras-Chave: brachytherapy; radiation source implants; radiation doses; dose rates; absorbed radiation doses; phantoms; simulation; monte carlo method

    Icon

  • IPEN-DOC 20160

    BELLEZZO, MURILLO . Desenvolvimento de um software de Monte Carlo para transporte de fótons em estruturas de voxels usando unidades de processamento gráfico / Development of a GPU Monte Carlo software for photon transport in voxel structures . 2014. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 83 p. Orientador: Helio Yoriyaz.

    Abstract: Sendo o método mais preciso para estimar a dose absorvida em radioterapia, o Método de Monte Carlo (MMC) tem sido amplamente utilizado no planejamento de tratamento radioterápico. No entanto, a sua eciência pode ser melhorada para aplicações clínicas de rotina. Nesta dissertação é apresentado o código CUBMC, um código de Monte Carlo que simula o transporte de fótons para cálculo de dose, desenvolvido na plataforma CUDA (Compute Unified Device Architecture). A simulação de eventos físicos é baseada no algoritmo presente no código PENELOPE, e as tabelas de seção de choque utilizadas são geradas pela rotina MATERIAL, também presente no código PENELOPE. Os fótons são transportados em objetos simuladores descritos por voxels. Existem duas abordagens distintas utilizadas para a simulação. A primeira delas obriga o fóton a realizar uma parada toda vez que cruza a fronteira de um voxel, a segunda e pelo Método de Woodcock, onde o fóton ignora a existência de fronteiras e é transportado em um meio homogêneo fictício. O código CUBMC tem como objetivo ser uma opção de código simulador que, ao utilizar a capacidade de processamento paralelo de unidades de processamento gráfico (GPU), apresente alto desempenho em máquinas compactas e de baixo custo, podendo assim ser aplicado em casos clínicos e incorporado a sistemas de planejamento de tratamento em radioterapia.

    Palavras-Chave: absorbed radiation doses; c codes; computer calculations; dose rates; dosimetry; monte carlo method; p codes; parallel processing; phantoms; photon transport; radiotherapy

    Icon

  • IPEN-DOC 20548

    BARREIRA, JACQUELINE S. ; HUET, SARAH D.P. ; VIVOLO, VITOR . Determination of radiation dose in surcace breast using two types of PMMA simulators. In: INTERNATIONAL NUCLEAR CHEMISTRY CONGRESS, 4th, September 14-19, 2014, Maresias, São Paulo. Proceedings... 2014.

    Palavras-Chave: x radiation; mammary glands; biomedical radiography; radiation detection; absorbed radiation doses; dosimetry; simulators

    Icon

  • IPEN-DOC 20155

    CAPELETI, FELIPE F. . Dosimetria em tomografia computadorizada e avaliação do perfil de dose empregando dosímetro fricke gel e a técnica de imageamento por ressonância magnética / Dosimetry for computed tomography and evaluation the dose profile using fricke gel dosimetry and magnetic ressonance imaging . 2014. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 73 p. Orientador: Letícia Lucente Campos Rodrigues.

    Abstract: Neste trabalho foi desenvolvido um novo método para a determinação das doses absorvidas nos exames de tomografia computadorizada, utilizando a dosimetria com Fricke gel desenvolvido no IPEN. Foram determinadas as doses absorvidas por diferentes metodologias de análise, como a espectrometria de absorção óptica, câmaras de ionização e imageamento por ressonância magnética. Foram realizados testes de limite mínimo de sensibilidade da solução de Fricke gel, repetitividade de sinal da solução de Fricke gel e dos equipamentos de tomografia computadorizada, sensibilidade de detecção, entre outros. Foram utilizados diferentes equipamentos de tomografia computadorizada com múltiplos detectores. A solução Fricke gel apresentou repetitividade melhor que ± 5,5% utilizando a técnica de espectrofotometria de absorção óptica e os equipamentos de tomografia computadorizada apresentaram repetitividade melhor que ± 0,2%. Foi desenvolvido um objeto simulador de crânio preenchido com a solução Fricke gel para a determinação da colimação total do equipamento e a distribuição de dose utilizando a técnica de imageamento tridimensional por ressonância magnética. A solução Fricke gel apresenta um preparo fácil e relativamente rápido, porém é necessária atenção para não haver contaminação e perder a solução. Com os resultados obtidos foi confirmada a aplicação deste tipo de dosimetria para os equipamentos de tomografia computadorizada.

    Palavras-Chave: computerized tomography; absorbed radiation doses; chemical dosemeters; magnetic resonance; absorption spectroscopy

    Icon

  • IPEN-DOC 20348

    VIANA, RODRIGO S.S. . Espectrometria e reconstrução de imagens tomográficas de emissão estimulada por nêutrons via algoritmo EM e Método de Monte Carlo / Spectrometry and emission tomographic image reconstruction stimulated by neutrons via EM algorithm and Monte Carlo Method . 2014. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 129 p. Orientador: Adimir dos Santos. Coorientador: Helio Yoriyaz.

    Abstract: A NSECT figura como uma nova técnica espectrográfica capaz de avaliar in vivo a concentração de elementos utilizando a reação de espalhamento inelástico (n,n). Desde sua introdução, várias melhorias vem sendo propostas com o objetivo de investigar aplicações para o diagnóstico clínico e redução da dose absorvida associada à aquisição tomográfica. Neste contexto, são apresentadas duas novas aplicações de diagnóstico utilizando as abordagens espectroscópica e tomográfica da NSECT. Uma nova metodologia também foi proposta para otimizar a amostragem do sinograma que está diretamente relacionado com a qualidade de reconstrução através do protocolo de irradiação. Os estudos realizados foram desenvolvidos com base em simulações com o código MCNP5. O diagnóstico de Carcinoma de Célula Renal (CCR) e a detecção de microcalcificações mamárias foram avaliadas nos estudos conduzidos utilizando um objeto simulador humano. Os resultados obtidos demonstram a habilidade da técnica NSECT em detectar a alteração da composição dos tecidos modelados em função do desenvolvimento das patologias avaliadas. O método proposto para a otimização dos sinogramas foi capaz de simular analiticamente a composição do meio irradiado permitindo que a qualidade de reconstrução e a dose efetiva fossem avaliados em função da taxa de amostragem. Entretanto, futuras pesquisas devem ser conduzidas para quantificar o limiar de detecção de acordo com os elementos selecionados.

    Palavras-Chave: emission computed tomography; image processing; spectroscopy; neutrons; inelastic scattering; diagnosis; absorbed radiation doses; carcinomas; kidneys; mammary glands; phantom; simulation; m codes; monte carlo method; algorithms

    Icon

  • IPEN-DOC 23340

    SOUZA, ANDERSON S. de . Estudo comparativo dos parâmetros associados à dose absorvida e controle de qualidade em aceleradores lineares com filtro aplainador (FF) e sem filtro aplainador (FFF) / Comparative study of the parameters associated with quality control and absorbed dose in linear accelerators with (FF) and without (FFF) flattening filter . 2017. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 66 p. Orientador: Maria Elisa Chuery Martins Rostelato.

    Abstract: A utilização da técnica de teleterapia para tratamento de câncer tem sido usada por anos com bons resultados clínicos. Em meados da década de 90, a remoção do filtro aplainador, item que compõe o cabeçote de um acelerador linear de uso clínico, tem sido objeto de estudos por demonstrar bons resultados no tratamento de alguns tipos de câncer. Técnicas utilizadas como Radioterapia de Intensidade Modulada (IMRT) e Radioterapia Estereotáxica (SRT), mostram-se mais eficazes quando não se utiliza o filtro aplainador. A empresa Varian Oncology lançou em 2012 um acelerador linear de uso clínico capaz de operar com o filtro aplainador (FF) e sem o filtro aplainador (FFF), o TrueBeam. Os objetivos desse trabalho são avaliar a homogeneidade de dois importantes parâmetros utilizados para o cálculo de dose nos pacientes submetidos ao tratamento com esse modelo de acelerador linear, a porcentagem de dose profunda (PDP) e índice de qualidade do feixe (TPR20/10). Os dados fornecidos para a análise foram cedidos pelo Hospital Israelita Albert Einstein (HIAE), Real Hospital Português (RHP) e 3 instituições norte-americanas. Através de uma análise estatística dos dados das instituições citadas pode-se observar melhor o comportamento desses parâmetro que demonstraram-se muito homogêneos e com erros menores que 1% na maioria dos casos, confirmando desse modo que os aceleradores lineares do modelo TrueBeam mantém na maioria das vezes uma boa concordância dos parâmetros analisados.

    Palavras-Chave: linear accelerators; radiotherapy; x radiation; external beam radiation therapy; filters; cones; absorbed dose range; absorbed radiation doses; comparative evaluations

    Icon

  • IPEN-DOC 18540

    MARTINS, ELAINE W.; POTIENS, MARIA da P.A. . Evaluation of radiation dose in computed tomography standard beams using simulators. In: INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 13th, May 13-18, 2012, Glasgow, Scotland. Proceedings... 2012.

    Palavras-Chave: computerized tomography; pediatrics; phantoms; surface air; kerma; absorbed radiation doses; dosimetry

    Icon

  • IPEN-DOC 19763

    SANTOS, T.C. dos; GONCALVES, J.A.C.; PASCOALINO, K.C.S.; HARKONEN, J.; BUENO, C.C. . Evaluation of radiation-hard magnetic Czochralski (MCz) silicon diodes in electron processing dosimetry. In: INSTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 1st, June 23-28, 2013, Praga, Republica Checa. Abstract... 2013.

    Palavras-Chave: czochralski method; silicon biodes; dosimetry; absorbed radiation doses; dose-response relationships; radiation injuries

    Icon

  • IPEN-DOC 22037

    FONSECA, GABRIEL P. ; YORIYAZ, HELIO . Experimentos de medidas de doses absorvidas com dosimetros termoluminescentes do tipo LiF-100 para uso clínico em radioterapia com feixes de elétrons. In: PROGRAMA INSTITUCIONAL DE BOLSAS DE INICIAÇÃO CIENTÍFICA, 12.; PROGRAMA DE BOLSAS E INICIAÇÃO CIENTÍFICA CNEN, 3., 9-10 de novembro, 2006, São Paulo, SP. Resumo expandido... 2006. p. 125-126.

    Palavras-Chave: experimental data; dosemeters; absorbed radiation doses; thermoluminescent dosimetry; lithium fluorides; radiotherapy; electron beams

    Icon

  • IPEN-DOC 22088

    FONSECA, GABRIEL P. ; YORIYAZ, HELIO . Experimentos de medidas de doses absorvidas com dosimetros termoluminescentes do tipo LiF-100 para uso clínico em radioterapia com feixes de elétrons. In: PROGRAMA INSTITUCIONAL DE BOLSAS DE INICIAÇÃO CIENTÍFICA, 13.; PROGRAMA DE BOLSAS E INICIAÇÃO CIENTÍFICA CNEN, 4., 29-30 de agosto, 2007, São Paulo, SP. Resumo expandido... 2007.

    Palavras-Chave: experimental data; dosemeters; absorbed radiation doses; thermoluminescent dosimetry; lithium fluorides; radiotherapy; electron beams

    Icon

  • IPEN-DOC 20608

    BELLEZZO, MURILLO ; NASCIMENTO, EDUARDO do ; YORIYAZ, HELIO . A GPU-based Monte Carlo dose calculation code for photon transport in a voxel phanton. In: INTERNATIONAL SYMPOSIUM ON SOLID STATE DOSIMETRY , 14th, April 13-16, 2014, Cusco, Peru. Proceedings... 2014. p. 377-390.

    Palavras-Chave: absorbed radiation doses; c codes; computer calculations; dose rates; dosimetry; monte carlo method; p codes; parallel processing; phantons; photon transport; radioherapy

    Icon

  • IPEN-DOC 21202

    FONSECA, GABRIEL P. . Monte Carlo modeling of the patient and treatment delivery complexities for high dose rate brachytherapy / Modelagem pelo método de Monte Carlo do paciente e das complexidades dos tratamentos braquiterápicos com alta taxa de dose . 2015. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 110 p. Orientador: Helio Yoriyaz.

    Abstract: Tratamentos braquiterápicos são comumente realizados conforme o relatório da American Association of Physicists in Medicine (AAPM), Task Group report TG-43U1, o qual define o formalismo para cálculo de dose absorvida na água e não considera a composição dos materiais, densidades, dimensões do paciente e o efeito dos aplicadores. Estes efeitos podem ser significantes, conforme descrito pelo recente relatório da AAPM, Task Group report TG- 186, que define diretrizes para que sistemas de planejamento modernos, capazes de considerar as complexidades descritas acima, sejam implementados. Esta tese tem como objetivo contribuir para o aumento da exatidão dos planejamentos de tratamento braquiterápicos, seguindo as recomendações do TG-186 e indo além do mesmo. Um software foi desenvolvido para integrar planejamentos de tratamento e simulações pelo método de Monte Carlo (MC); modelos acurados, CAD-Mesh, foram utilizados para representar aplicadores braquiterápicos; Grandezas utilizadas para reportar dose absorvida, Dw,m (dose para água no meio) e Dm,m (dose para o meio no meio), foram calculadas para um tratamento de cabeça e pescoço, considerando a teoria para pequenas (SCT small cavity theory) e grandes cavidades (LCT large cavity theory); a componente da dose em razão do movimento da fonte foi avaliada para tratamentos de próstata e ginecológicos. Perfis de velocidade obtidos na literatura foram utilizados; medidas de velocidade de uma fonte braquiterapica foram realizadas com uma câmera de alta taxa de aquisição. Cálculos de dose obtidos usando MC (incluindo a composição e densidade dos tecidos, ar e o aplicador) mostram sobredoses de aproximadamente 5% dentro do volume alvo, em um tratamento ginecológico, quando comparados aos resultados obtidos com um meio homogêneo de água. Por sua vez, subdoses de aproximadamente 5% foram observadas ao considerar a composição dos tecidos e regiões com ar em um tratamento intersticial de braço. Um aplicador cilíndrico oco resultou na sobredose observada no caso ginecológico, ressaltando a necessidade de modelos acurados para representar os aplicadores. Os modelos CAD-Mesh utilizados incluem um aplicador Fletcher-Williamson, com blindagem, e um balão deformável para irradiação de mama. Os resultados obtidos com estes modelos são equivalentes aos obtidos com modelos geométricos convencionais. Este recurso pode ser conveniente para aplicadores complexos e/ou quando o projeto dos aplicadores for disponibilizado pelo fabricante. Cálculos de dose, com a composição real dos tecidos humanos, podem apresentar diferenças significativas em razão da grandeza adotada. Diferenças entre Dm,m e Dw,m (SCT ou LCT) chegam a 14% em razão da composição do osso. A metodologia adotada (SCT ou LCT) resulta em diferenças de até 28% para o osso e 36% para os dentes. A componente de dose de trânsito também pode levar a diferenças significativas, uma vez que baixas velocidades ou movimentos uniformemente acelerados foram descritos na literatura. Considerando a pior condição e sem incluir nenhuma correção no tempo de parada, a dose de trânsito pode chegar a 3% da dose prescrita para um caso ginecológico, com 4 cateteres, e até 11.1% da dose prescrita para um tratamento de próstata, com 16 cateteres. A dose de trânsito para a fonte avaliada (velocidade obtida experimentalmente) não é uniformemente distribuída e pode levar a sub ou sobredoses de até 1.4% das doses comumente prescritas (310 Gy). Os tópicos estudados são relevantes para tratamentos braquiterápicos e podem contribuir para o aumento de sua acurácia. Os efeitos estudados podem ser avaliados com o uso do software, associado a um código MC, desenvolvido.

    Palavras-Chave: brachytherapy; iridium 192; absorbed radiation doses; monte carlo method; algorithms; calculation methods; computer codes

    Icon

  • IPEN-DOC 18637

    CAVINATO, C.C.; SAKURABA, R.K.; SANTOS, E.S.; RODRIGUES JUNIOR, O. ; CAMPOS, L.L. . MRI evaluation optimization of Fricke Xylenol gel dosimeter irradiated with clinical photon beams. In: INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 12th, October 7-12, 2012, Rio de Janeiro, RJ. Abstract... 2012.

    Palavras-Chave: magnetic resonance; chemical dosemeters; gels; absorbed radiation doses; spatial resolution; radiation dose distributions; phantoms; quality control

    Icon

  • IPEN-DOC 20794

    CAVALCANTE, FERNANDA ; PECEQUILO, BRIGITTE R.S. . Natural and anthropogenic radionuclides in Brazilian commercial dog food: preliminary results. In: INTERNATIONAL CONFERENCE ON RADIOECOLOGY AND ENVIRONMENTAL RADIOACTIVITY, 3rd, September 7-12, 2014, Barcelona, Espanha. Proceedings... 2014.

    Palavras-Chave: absorbed radiation doses; americium 241; brazil; cats; cesium 137; cobalt 60; concentration ratio; dogs; food; gross domestic product; gamma spectroscopy; indium 100; ingestion; iodine 131; nitrogen; polyethylenes; potassium 40; radioecological concentration; radionuclide kinetics; ge semiconductor detectors

    Icon

  • IPEN-DOC 20799

    FONSECA, LEANDRO M. ; PECEQUILO, BRIGITTE R.S. . Natural radioactivity in wall paints: preliminary results. In: INTERNATIONAL NUCLEAR CHEMISTRY CONGRESS, 4th, September 14-19, 2014, Maresias, São Paulo. Abstract... 2014.

    Palavras-Chave: natural radioactivity; paints; building materials; radium 226; thorium 232; potassium 40; absorbed radiation doses; radiation effects

    Icon

  • IPEN-DOC 20440

    VIEIRA, FABIO P.B.; BEVILACQUA, JOYCE S.; RODRIGUES JUNIOR, ORLANDO . Pós-processamento de espectros de RPE de substâncias dosimétricas por filtragem da transformada discreta de Fourier. In: CONGRESSO DE PROTEÇÃO CONTRA RADIAÇÕES DA COMUNIDADE DE PAISES DE LÍNGUA PORTUGUESA, 4.; CONGRESSO INTERNACIONAL DE RADIOPROTEÇÃO INDUSTRIAL, 6.; ENCONTRO DE PROTEÇÃO RADIOLÓGICA DO CONE SUL, 1.; CONGRESSO BRASILEIRO DE PROTEÇÃO RADIOLÓGICA, 4., August 26-29, 2014, Gramado, RS. Anais... 2014.

    Palavras-Chave: electron spin resonance; absorbed radiation doses; spectra; radioactive materials; fourier analysis; algorithms

    Icon

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.