Navegação IPEN por assunto "radiation detection"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 18817

    FIOR, L.; NICOLOSI CORREA, J.; PASCHUK, S.A.; DENYAK, V.V.; SCHELIN, H.R.; PECEQUILO, B.R.S. ; KAPPKE, J.. Activity measurements of radon from construction materials. Applied Radiation and Isotopes, v. 70, n. 7, p. 1407-1410, 2012.

    Palavras-Chave: alpha particles; bricks; clays; concrete blocks; dose equivalents; gamma spectroscopy; potassium 40; radiation detection; radium 226; radon; radon 222; thorium 232

    Icon

  • IPEN-DOC 17278

    COELHO, TALITA S.; FERNANDES, MARCO A.R.; YORIYAZ, HELIO ; LOUZADA, MARIO J.Q.. Analise dosimétrica de perfis de distribuições radiais de doses relativas de um aplicador de betaterapia de sup(90)Sr+sup(90)Y utilizando o código MCNP-4C e filmes radiocrônicos. Revista Brasileira de Fisica Medica, v. 4, n. 3, p. 7-10, 2011.

    Palavras-Chave: beta dosimetry; dose equivalents; dosimetry; films; m codes; measuring methods; radiation detection; radiation dose distributions; radiation dose units; radiation doses; radiation monitoring; radiation protection; radiations; strontium; strontium 90; yttrium; yttrium 90

    Icon

  • IPEN-DOC 09357

    GROSSI, F.H.; CAMPOS, L.L. ; SCHOR, P.; MELO JUNIOR, L.A.S.. Aplicacao da termoluminescencia fotoestimulada na area oftalmologica usando-se CaSOsub(4):Dy. Revista Brasileira de Pesquisa e Desenvolvimento, v. 4, n. 3, Parte 1Parte 1, p. 884-887, 2002.

    Palavras-Chave: radiation detection; excimer lasers; thermoluminescence; thermoluminescent dosemeters; calcium sulfates; dosimetry; radiation protection; ophthalmology; medical establishments

    Icon

  • IPEN-DOC 08723

    GROSSI, F.H.; CAMPOS, L.L. ; SCHOR, P.; MELO JUNIOR, L.A.S.. Aplicacao da termoluminescencia fotoestimulada na area oftalmologica usando-se CaSOsub(4):Dy. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; NATIONAL MEETING ON NUCLEAR APPLICATIONS, 6th, Aug. 11-16, 2002, Rio de Janeiro, RJ. Proceedings... Rio de Janeiro: ABEN, 2002, 2002.

    Palavras-Chave: radiation detection; excimer lasers; thermoluminescence; thermoluminescent dosemeters; calcium sulfates; dosimetry; radiation protection; ophthalmology; medical establishments

    Icon

  • IPEN-DOC 12726

    ARAUJO, MICHEL M. . Aplicação do método microbiológico DEFT/APC e do teste do cometa na detecção do tratamento com radiação ionizante de hortaliças minimamente processadas / Application of the microbiological method DEFT/APC and DNA comet assay to detect ionizing radiation processing of minimally processed vegetables . 2008. Dissertação (Mestrado) - Instituto de Pesquisas Energéticas e Nucleares - IPEN/CNEN-SP, São Paulo. 65 p. Orientador: Anna Lucia. DOI: 10.11606/D.85.2008.tde-21092009-165505

    Abstract: O comércio de vegetais minimamente processados (VMP) tem crescido substancialmente nos últimos anos devido a sua conveniência, frescor e aparente salubridade. No entanto, o processamento mínimo não reduz as populações de microrganismos patogênicos para níveis seguros. A irradiação de alimentos é utilizada para estender a vida de prateleira e inativar patógenos presentes nos alimentos. Seu uso combinado com o processamento mínimo poderia aumentar a segurança e qualidade dos VMP. Dois diferentes métodos de detecção de alimentos irradiados, um biológico, o DEFT/APC, e outro bioquímico, o teste do cometa, foram aplicados a VMP com o objetivo de testar sua aplicabilidade na detecção do tratamento por radiação. O DEFT/APC é um método de varredura microbiológico baseado no uso da técnica de epifluorescência direta em filtro (DEFT) e da contagem padrão em placas (APC). O teste do cometa detecta o dano no DNA devido, por exemplo, a radiação ionizante. Amostras de acelga, agrião, alface, catalônia, couve, escarola, espinafre e repolho do comércio varejista foram irradiadas com 0,5kGy e 1,0kGy utilizando um irradiador de 60Co. O processamento por irradiação garantiu a redução de pelo menos dois ciclos logarítmicos nas populações de microrganismos aeróbios e psicrotróficos. Em geral, com o aumento das doses de radiação, as contagens DEFT se mantiveram similares independentemente do processamento por irradiação, enquanto as contagens APC diminuíram gradualmente. A diferença das duas contagens aumentou gradualmente com o incremento da dose em todas as amostras. Uma diferença entre o valor de DEFT e do APC maior a 2,0 log seria indicativa de que o VMP foi tratado por irradiação. O teste do cometa permitiu distinguir amostras não irradiadas das irradiadas, que mostraram diferentes tipos de cometas decorrentes da fragmentação do DNA. Tanto o método DEFT/APC quanto o teste do cometa foram satisfatoriamente utilizados como métodos de varredura para a detecção do tratamento por irradiação.

    Palavras-Chave: vegetables; microorganisms; food processing; radiation detection; dna; comets; bioassay

    Icon

  • IPEN-DOC 04975

    MEDEIROS, I.M.M.A.; ZAMBONI, C.B. ; MEDEIROS, J.A.G.; OLIVEIRA, V.X.; KOSKINAS, M.F. ; CAMARGO, S.P.; DALAQUA JUNIOR, L.. Applicability study of plastic scintillation detectors for beta radiation measurements. In: 4th MEETING ON NUCLEAR APPLICATIONS, ENCONTRO NACIONAL DE APLICACOES NUCLEARES, August 18-22, 1997, Pocos de Caldas, MG. 1997. p. 549-552.

    Palavras-Chave: beta particles; beta detection; plastic scintillation detectors; radiation detection; radiation detectors

    Icon

  • IPEN-DOC 11140

    TAKEDA, M.N.; DIAS, M.S. ; KOSKINAS, M.F. . Application of Monte Carlo simulation to sup(134)Cs standardization by means of 4 pi-beta-gamma coincidence system. IEEE Transactions on Nuclear Science, v. 52, n. 5, Part. 3, p. 1716-1720, 2005.

    Palavras-Chave: brazilian cnen; coincidence methods; cesium 134; monte carlo method; simulation; standardization; radioisotopes; activity levels; gamma decay; beta decay; proportional counters; radiation detection

    Icon

  • IPEN-DOC 14851

    ARAUJO, M.M.; DUARTE, R.C.; SILVA, P.V.; MARCHIONI, E.; VILLAVICENCIO, A.L.C.H. . Application of the microbiological method DEFT/APC to detect minimally processed vegetables treated with gamma radiation. Radiation Physics and Chemistry, v. 78, n. 7-8, p. 691-693, 2009.

    Palavras-Chave: cobalt 60; gamma radiation; marketing; microorganisms; pathogens; radappertization; radiation detection; radiation doses; storage life

    Icon

  • IPEN-DOC 13975

    PINTO, T.N.O.; CECATTI, S.G.P.; GRONCHI, C.C.; CALDAS, L.V.E. . Application of the OSL technique for beta dosimetry. In: INTERNATIONAL CONFERENCE ON SOLID STATE DOSIMETRY, 15th, July 8-13, 2007, Delft, Netherland. Proceedings... 2007. p. 332-334.

    Palavras-Chave: aluminium oxides; beta dosimetry; energy dependence; luminescence; occupational exposure; occupational safety; personnel dosimetry; radiation detection

    Icon

  • IPEN-DOC 06166

    VILLAVICENCIO, ANNA L.C.H. . Avaliacao dos efeitos da radiacao ionizante de sup60Co em propriedades fisicas , quimicas e nutricionais dos feijoes PHASEOLUS VULGARIS L. e VIGNA UNGUICULATA (L.) WALP. 1998. Tese (Doutoramento) - Faculdade de Ciencias Farmaceuticas, Universidade de Sao Paulo - CF/USP, Sao Paulo. 138 p. Orientador: Jorge Mancini Filho.

    Palavras-Chave: beans; ionizing radiations; gamma radiation; cobalt 60; radiation effects; physical properties; chemical properties; nutrients; radiation detection; food

    Icon

  • IPEN-DOC 25575

    WAKASUGI, DENISE S.M. . Avaliação da concentração de 226 Ra, 228 Ra, 210Pb e 210 Po e caracterização química inorgânica das águas minerais dos Parques das Águas de Águas de Contendas e Lambari - MG / Assessment of the concentration of the 226Ra, 228Ra, 210Pb and 210Po and inorganic chemical characterization of mineral waters of Parques das Águas of Águas de Contendas and Lambari - MG . 2018. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 273 p. Orientador: Sandra Regina Damatto. DOI: 10.11606/D.85.2019.tde-01022019-111224

    Abstract: A radioatividade natural das águas é proveniente dos elementos radioativos nela dissolvidos e dos gases de alguns elementos radioativos difundidos das rochas subterrâneas. Quando se considera a geoquímica dos radionuclídeos naturais no ambiente aquático, os elementos de maior interesse do ponto de vista de risco à saúde são os isótopos de rádio (Ra), os de radônio (Rn) e os de urânio (U), por apresentarem maior solubilidade em água. Uma vez que a dieta humana é a principal fonte de absorção da radioatividade natural e de exposição interna do homem, o consumo de águas minerais pode aumentar significativamente a probabilidade de ingestão de altas concentrações de radionuclídeos naturais nelas dissolvidos. O objetivo geral do presente trabalho foi determinar as concentrações de atividade dos radionuclídeos 226Ra, 228Ra, 210Pb e 210Po nas águas minerais das fontes dos Parques das Águas de Águas de Contendas e de Lambari, MG, para avaliar as doses efetivas comprometidas devido à ingestão destas águas e realizar a caracterização química inorgânica, determinando os elementos químicos Ag, Al, As, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Se, Ti, V e Zn. Os objetivos específicos foram verificar a influência da sazonalidade na concentração de atividade dos radionuclídeos e dos elementos químicos analisados e determinar os parâmetros físicos e físico-químicos como temperatura, vazão, pH, CE, STD. As técnicas analíticas empregadas para determinar as concentrações de atividade foram a de alfa e beta total após separação radioquímica para os radionuclídeos 226Ra, 228Ra e 210Pb com determinação em detector proporcional de fluxo gasoso e baixa radiação de fundo e de espectrometria alfa após separação radioquímica para o radionuclídeo 210Po com determinação em espectrômetro alfa. Os valores de concentrações de atividade obtidos variaram de 7,71 ± 0,27 mBq L-1 a 250 ± 3 mBq L-1 para o 226Ra, de < LID (3,7 ± 0,1 mBq L-1) a 244 ± 4 mBq L-1 para o 228Ra, de < LID (4,9 ± 0,4 mBq L-1) a 57,1 ± 3,0 mBq L-1 para o 210Pb e de < LID (3,3 ± 0,4 mBq L-1) a 15,7 ± 1,1 mBq L-1 para o 210Po. O cálculo da dose efetiva comprometida para a ingestão de água mineral contendo 226Ra, 228Ra, 210Pb e 210Po foi realizado para o corpo inteiro (He), em crianças de 5 anos, adolescentes de 15 anos e adultos até 70 anos, e para os principais órgãos afetados (Ho), em adultos até 70 anos, após a ingestão da água mineral. Os maiores valores de dose para o corpo inteiro foram de 273 ± 14 μSv a-1 para o 226Ra, 945 ± 15 μSv a-1 para o 228Ra, 79,2 ± 4,2 μSv a-1 para o 210Pb, em adolescentes de 15 anos e, de 40,4 ± 2,9 μSv a-1 para o 210Po em crianças de 5 anos. Para a caracterização química inorgânica foi utilizada a espectrometria de fluorescência de raios X por energia dispersiva (EDXRF) que apresentou os elementos Co e Cu abaixo do limite mínimo de quantificação e os elementos Ag e V com maiores concentrações e, a espectrometria de emissão óptica com plasma de argônio (ICP-OES) que apresentou o elemento Cr abaixo do limite mínimo de quantificação e os elementos Ca, Fe e Na com maiores concentrações. Assim, mediante os resultados obtidos e aos testes estatísticos aplicados: análise de Cluster, coeficiente de correlação de Pearson e ANOVA, conclui-se que existe a correlação entre a precipitação pluviométrica e a sazonalidade das concentrações dos radionuclídeos e dos elementos químicos inorgânicos em estudo, que o radionuclídeo que apresentou maior concentração em Águas de Contendas foi o 228Ra para a maioria das fontes e em Lambari foi o 226Ra, também na maioria das fontes e, como consequência, as maiores doses obtidas também foram para os radionuclídeos naturais 226Ra e 228Ra.

    Palavras-Chave: radioactivity; natural radioactivity; environmental exposure; radium 226; radium 228; polonium 210; lead 210; internal irradiation; biogeochemistry; isotopes; detection; isotope separation; radiation detection; water treatment; ground water; underground storage; public health; drinking water; risk assessment; safety analysis; brazil

    Icon

  • IPEN-DOC 03067

    ALBUQUERQUE, M.P.P. ; CALDAS, L.V.E. ; XAVIER, M. . Calibracao de dosimetros clinicos por componentes. In: 40a. REUNIAO ANUAL DA SBPC, 10-16 de julho, 1988, Sao Paulo, SP. 1988.

    Palavras-Chave: calibration; dosemeters; gamma radiation; ionization chambers; radiation detection

    Icon

  • IPEN-DOC 12017

    GENEZINI, FREDERICO A. ; FARIAS, EMERSON E.G. DE; ZEVALLOS CHAVEZ, JUAN Y.; CRUZ, MANOEL T.F. da. Calibration detector measurement for large sources. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: calibration; computerized simulation; efficiency; environmental materials; europium 152; gamma spectroscopy; monte carlo method; radiation detection; radiation sources; sand

    Icon

  • IPEN-DOC 06438

    SAUEIA, CATIA H.R. . Caracterizacao radioquimica do fosfogesso e implicacoes radiologicas de sua utilizacao como material de construcao. 1998. Dissertacao (mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. 72 p. Orientador: Barbara Pacci Mazzilli.

    Palavras-Chave: building materials; phosphate rocks; gypsum; radium 226; thorium 232; potassium 40; radiochemistry; radiation detection; radiation doses

    Icon

  • IPEN-DOC 25700

    SOUZA, CLAYTON H. de . Caracterização dosimétrica e modelagem computacional de um detector do tipo transistor de efeito de campo metal-óxido-semicondutor / Dosimetric characterization and computational modeling of metal-oxide-semiconductor field effect transistor type detector . 2019. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 211 p. Orientador: Julian Marco Barbosa Shorto. DOI: 10.11606/D.85.2019.tde-24062019-090509

    Abstract: A dosimetria in vivo é uma ferramenta essencial para programas de garantia de qualidade no campo da radioterapia, sendo um procedimento comumente realizado com TLDs ou diodos. No entanto, um dosímetro que vem em crescente popularidade nos últimos anos é o detector do tipo transistor de efeito de campo de metal-óxido-semicondutor (MOSFET). Os dosímetros MOSFET preenchem todas as características necessárias para realização da dosimetria in vivo, uma vez que possuem tamanho pequeno, boa precisão e viabilidade de medição, além de seu fácil manuseio. No entanto, seu verdadeiro diferencial é permitir a leitura de dose em tempo real, possibilitando intervenção imediata na correção de desvios de parâmetros físicos e na antecipação de pequenas alterações anatômicas no paciente durante um tratamento. Assim, foi proposta a caracterização dosimétrica do detector microMOSFET TN-502RDM-H e a construção de seu respectivo modelo computacional em MCNP6. Os resultados mostraram que o dosímetro MOSFET possui boa reprodutibilidade, boa linearidade e independência energética para feixes de altas energias de fótons e elétrons. Com relação a linearidade, destaca-se o excelente desempenho do detector MOSFET para valores doses acima de 50cGy, tendo apresentado uma precisão de 0,3%. Além disso, foi obtido um fator de calibração único, considerando fótons e elétrons de altas energias, com 2,9% de reprodutibilidade. Também foram constatadas dependências angulares de 4% e 13% para irradiações com e sem a condição de equilíbrio eletrônico, respectivamente. Foi encontrada uma diferença de 8% na resposta entre fótons de baixas energias nas qualidades RQR 3 e RQR 10. Com relação ao modelo computacional, a utilização das técnicas caracterização estrutural de MEV e EDS possibilitaram estimar a geometria e a composição do dispositivo MOSFET. Dos resultados do modelo computacional, ressalta-se a excelente concordância da dependência energética simulada em MCNP6 com a calculada analiticamente e também com a literatura. Por fim, o dosímetro MOSFET mostrou bom desempenho dosimétrico, confirmando seu potencial clínico; fato este que, certamente, contribui para sua maior aceitação na radioterapia. Somado a isto, a obtenção de um modelo computacional adequado proporciona um leque de oportunidades para trabalhos futuros, possibilitando o aprimoramento do instrumento nos mais diversos procedimentos de tratamento do câncer por radiação.

    Palavras-Chave: dosimetry; in vivo; dosemeters; radiation detection; computerized simulation; semiconductor devices; personnel dosimetry; mosfet; x-ray detection; oxides; metals; cesium 137; cobalt 60; field effect transistors; identification systems; charged-particle transport; neutral-particle transport; monte carlo method; computer codes

    Icon

  • IPEN-DOC 08491

    CALDAS, L.V.E. ; TEIXEIRA, M.I.. Commercial glass for high doses using different dosimetric techniques. Radiation Protection Dosimetry, v. 101, n. 1/4, p. 149-152, 2002.

    Palavras-Chave: dosimetry; dosemeters; glass; radiation detection; gamma radiation; cobalt 60; radiation doses; densitometers; spectrophotometers; thermoluminescence

    Icon

  • IPEN-DOC 08470

    CALDAS, L.V.E. ; TEIXEIRA, M.I.. Commercial glass for high doses using different dosimetric techniques. In: INTERNATIONAL CONFERENCE ON SOLID STATE DOSIMETRY, 13th, July 9-13, 2001, Athens, Greece. 2001.

    Palavras-Chave: dosimetry; dosemeters; glass; radiation detection; gamma radiation; cobalt 60; radiation doses; densitometers; spectrophotometers; thermoluminescence

    Icon

  • IPEN-DOC 15706

    YOSHIZUMI, MAIRA T.; CALDAS, LINDA V.E. . Comparative study of the response stability of monitor ionization chambers in X-radiation beams. Radioproteção, v. 2, n. 16-17, p. 42-47, 2010.

    Palavras-Chave: alara; dosimetry; experimental data; international organizations; ionization chambers; legislation; public health; quality assurance; quality control; radiation detection; radiation doses; radiation protection; recommendations

    Icon

  • IPEN-DOC 19734

    VILLAVICENCIO, ANNA L.; ALVAREZ, DAMARIS; MANCIN FILHO, JORGE; MARCHIONI, ERIC; AOUD WERNER, DALAL. Comparisson of rapid and conventional extraction methods for detection of 2DCB in brazilian irradiated foodstuffs. In: INTERNATIONAL SYMPOSIUM ON RECENT ADVANCES IN FOOD ANALYSIS, 6th, November 5-8, 2013, Prague, Czech Republic. Abstract... 2013. p. 440.

    Palavras-Chave: brazil; food; food processing; irradiation; radiation detection; radiation doses; extraction; acetonitrile

    Icon

  • IPEN-DOC 26065

    ANTONIO, P.L. ; CALDAS, L.V.E. . Comportamento do sinal TL/OSL e PTTL/PTOSL após tratamento térmico pós-irradiação com fonte de 60Co, em amostras de LiF:Mg,Ti e CaSO4:Dy. In: INTERNATIONAL JOINT CONFERENCE RADIO, September 16-20, 2019, São Paulo, SP. Resumo expandido... Maringá, PR: Sociedade Brasileira de Proteção Radiológica, 2019.

    Palavras-Chave: dosimetry; thermoluminescence; optical equipment; ultraviolet radiation; radiation detection; heat treatments; cobalt 60; thermoluminescent dosemeters; thermoluminescent dosimetry

    Icon

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.