Determination of k0 and Q0 for 74Se, 113In, 186W and 191Ir targets applying covariance analysis
Carregando...
Data
2019
Data de publicação:
Orientador
Título da Revista
ISSN da Revista
Título do Volume
É parte de
É parte de
É parte de
Applied Radiation and Isotopes
Resumo
In the present work, the determinations of k0 and Q0 for 74Se, 113In, 186W and 191Ir targets were performed. The
irradiations were conducted near the core of the IEA-R1 4.5MW swimming-pool nuclear research reactor of the
Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP – Nuclear and Energy Research Institute), in São
Paulo, Brazil. The irradiation position was chosen where the neutron spectrum shape parameter α is very close to
zero. For this reason, the correction to be applied for the determination of Q0 is very close to one, thus improving
the accuracy of the results. For each experiment, two irradiations were carried out in sequence: the first one with
bare samples and the second with a cadmium cover around the samples. All partial uncertainties were considered,
applying the covariance matrix methodology. The final results were compared with the literature.
Como referenciar
BARROS, L.F.; RIBEIRO, R.V.; DIAS, M.S.; MORALLES, M.; SEMMLER, R.; YAMAZAKI, I.M.; KOSKINAS, M.F. Determination of k0 and Q0 for 74Se, 113In, 186W and 191Ir targets applying covariance analysis. Applied Radiation and Isotopes, v. 154, p. 1-7, 2019. DOI: 10.1016/j.apradiso.2019.108846. Disponível em: http://repositorio.ipen.br/handle/123456789/30404. Acesso em: 25 Apr 2024.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.