SANCHEZ, A.; SANTOS, A.; YORIYAZ, H.. Modelagem de olho humano para projeto de simuladores oftalmicos para aplicacoes clinicas. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; NATIONAL MEETING ON NUCLEAR APPLICATIONS, 6th, Aug. 11-16, 2002, Rio de Janeiro, RJ. Proceedings... Rio de Janeiro: ABEN, 2002, 2002.
SANCHES, MATIAS P.; CARNEIRO, JANETE C.G.G.. Dose distribution behaviour of the IPEN-CNEN/Brasil workers. In: INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, October 19-24, 2008, Buenos Aires, Argentina. Proceedings...
2008.
ABREU, RODRIGO T.; ANGELOCCI, LUCAS V.; NOGUEIRA, BEATRIZ R.; SANTOS, HAMONA N. dos; ZEITUNI, CARLOS A.; ROSTELATO, MARIA E.C.M.. Anisotropy function of a new 192-Ir brachytherapy source. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 175-185.Abstract: Brachytherapy is a type of radiotherapy that uses radioactive sources (seeds, wires, among others) close to the tumor. Is important to provide a detailed description of seed dosimetry, so only the tumor will be irradiated avoiding unnecessary dose on adjacent organs and structures. To evaluate the dosimetric parameter of the anisotropy function for a new brachytherapy source, this work proposes the use of microcube TLD-100 dosimeters to find the dose rate using the AAPM Task Group 43 protocol (TG-43). The anisotropy function represents dose distribution around the source and has a major role for characterization of a new iridium source being implemented in Brazil. The value of D(r,θ) was measured using Solid Water phantoms, r value being the distance from the geometric center of the source to the position of the dosimeter on the phantom, and θ being the angle formed between the longitudinal axis of the source and the line connecting the geometric center to the TLD. Monte Carlo calculations were performed to evaluate the anisotropy function to validate the experimental measurements. For each distance value (r), an anisotropy function was plotted (1.0, 2.0, 3.0, 4.0, 5.0, and 10.0 cm). The results obtained with Monte Carlo calculations agreed ±2% with the experimental values for r greater than 3.0 cm, so these results show a good distribution of dose around the seed considering the high energy of 192-Ir (average of 380 KeV) and encapsulation thickness.
BRAVIM, A.; SAKURABA, R.K.; CAMPOS, L.L.. Dose distribution assessment (comparison) in the target volume treated with vmat giben by the planning system and evaluated by TL dosimeters. In: CONGRESSO DE PROTEÇÃO CONTRA RADIAÇÕES DA COMUNIDADE DE PAISES DE LÍNGUA PORTUGUESA, 4.; CONGRESSO INTERNACIONAL DE RADIOPROTEÇÃO INDUSTRIAL, 6.; ENCONTRO DE PROTEÇÃO RADIOLÓGICA DO CONE SUL, 1.; CONGRESSO BRASILEIRO DE PROTEÇÃO RADIOLÓGICA, 4., August 26-29, 2014, Gramado, RS. Proceedings...
2014.
DEL NERO, RENATA A.; NAKANDAKARI, MARCOS V.N.; YORIYAZ, HELIO. Validating a virtual source model based in Monte Carlo Method for profiles and percent deep doses calculation. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017. Abstract: The Monte Carlo method for radiation transport data has been adapted for medical physics application. More specifically, it has received more attention in clinical treatment planning with the development of more efficient computer simulation techniques. In linear accelerator modeling by the Monte Carlo method, the phase space data file (phsp) is used a lot. However, to obtain precision in the results, it is necessary detailed information about the accelerator's head and commonly the supplier does not provide all the necessary data. An alternative to the phsp is the Virtual Source Model (VSM). This alternative approach presents many advantages for the clinical Monte Carlo application. This is the most efficient method for particle generation and can provide an accuracy similar when the phsp is used. This research propose a VSM simulation with the use of a Virtual Flattening Filter (VFF) for profiles and percent deep doses calculation. Two different sizes of open fields (40 x 40 cm² and 40√2 x 40√2 cm²) were used and two different source to surface distance (SSD) were applied: the standard 100 cm and custom SSD of 370 cm, which is applied in radiotherapy treatments of total body irradiation. The data generated by the simulation was analyzed and compared with experimental data to validate the VSM. This current model is easy to build and test.
BRANCO, I.S.L.; ANTUNES, P.C.G.; SIQUEIRA, P.T.D.; SHORTO, J.M.B.; YORIYAZ, H.. Estudo dos efeitos de composição e densidade de materiais tecido equivalentes na distribuição de dose longitudinal em protonterapia / Study of the composition and density effects of tissue equivalent materials on the longitudinal dose distribution in proton therapy. In: CONGRESSO BRASILEIRO DE FÍSICA MÉDICA, 24., 21-24 de agosto, 2019, Santos, SP. Anais... São Paulo, SP: Associação Brasileira de Física Médica, 2019. p. 1-6.Abstract: A eficiência de procedimentos radioterápicos depende do equilíbrio entre o fornecimento de altas doses conformadas ao
volume tumoral e a restrição das doses recebidas pelos tecidos e órgãos saudáveis circundantes. Sendo uma modalidade
de radioterapia, a protonterapia destaca-se neste cenário por possuir vantagens dosimétricas, que, quando combinadas
com avanços tecnológicos, permitem que um grande potencial na conformidade da distribuição de dose. Este trabalho
visa contribuir em um estudo dosimétrico, especificamente considerando os efeitos da heterogeneidade devido à presença
de materiais tecido equivalentes com diferentes densidades e composições químicas, de modo a analisar qual destes
parâmetros exerce maior influência na distribuição de dose longitudinal. A metodologia desenvolvida neste trabalho foi
baseada em simulações de Monte Carlo com o código GEANT4 (através da interface TOPAS). Os objetos simuladores
cilíndricos representados foram compostos inteiramente por diversos materiais tecido-equivalentes. Três grupos de estudo
guiaram as simulações, o primeiro manteve a composição e densidade originais dos materiais, ao seguinte foi atribuída a
todos os materiais heterogêneos a mesma densidade da água, mas mantiveram-se suas composições químicas originais;
e por fim, foram realizadas simulações com as densidades originais dos materiais heterogêneos e composição química
da água para todos os casos. Através da análise da distribuição de dose longitudinal variando com a profundidade, foi
possível observar o comportamento da influência dos parâmetros de composição e densidade no alcance do feixe (d90)
para os diferentes materiais e energias analisados. O estudo mostrou que, o efeito que a densidade dos materiais tecido
equivalentes exerce sobre a deposição de dose é mais expressivo que o efeito de sua composição. A maior exatidão no
range de tratamento permite evitar uma sub ou sobre dosagem da área irradiada. Esta é uma das diversas linhas de
pesquisa que contribuem para a diminuição das incertezas em protonterapia.
MAZER, AMANDA C.; SHORTO, JULIAN M.B.; SIQUEIRA, PAULO T.D.; NAKANDAKARI, MARCOS V.N.; RIBEIRO, VICTOR A.B.; YORIYAZ, HELIO. Análise da sensibilidade do ArcCHECK® / ArcCHECK® sensitivity analysis. In: CONGRESSO BRASILEIRO DE FÍSICA MÉDICA, 24., 21-24 de agosto, 2019, Santos, SP. Anais... São Paulo, SP: Associação Brasileira de Física Médica, 2019. p. 1-5.Abstract: Este artigo apresenta uma análise da sensibilidade do sistema dosimétrico ArcCHECK, através de comparações entre medidas experimentais envolvendo alguns tipos de deslocamentos mecânicos e medidas de uma referência fixa. O ArcCHECK é um sistema que contém 1386 diodos dispostos de forma helicoidal e que permite realizar medições para Controle de Qualidade de técnicas de radioterapia mais modernas e complexas. Foram feitas algumas medidas iniciais de repetibilidade e de linearidade e, em sequência, análises da capacidade do dispositivo em identificar erros de deslocamentos em diferentes direções, bem como a visualização de efeitos da resolução dos diodos. Foram encontradas diferenças consideráveis nos valores de dose entre deslocamentos pequenos e a referência. Também foram observadas deformações nas curvas de isodose para determinados ângulos de irradiação do sistema. O ArcCHECK foi considerado bastante sensível, dada a metodologia de análise, porém deve ser utilizado com cautela quando posicionado para realizar Controle de Qualidade.
BRANCO, ISABELA S.L.; ANTUNES, PAULA C.G.; CAVALIERI, TASSIO A.; MOURA, EDUARDO S.; ZEITUNI, CARLOS A.; YORIYAZ, HELIO. I-125 seed dose estimates in heterogeneous phantom. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 12th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 19th; MEETING ON NUCLEAR INDUSTRY, 4th, October 4-9, 2015, São Paulo, SP. Proceedings...
2015.
SILVA, VITOR M.A. da; SOUSA, JURANDIR A. de; MARTINS, PATRICIA de A.; FUKUMORI, NEUZA T.O.; SILVA, NATANAEL G. da; MATSUDA, MARGARETH M.N.. Dose calibrator and gamma counter: comparison of results in MIBI-TEC® biological distribution. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 1860-1864.Abstract: To ensure that pharmaceutical products have and maintain the structure, identity, purity, concentration, potency and safety characteristics required for their use, there is a set of standard procedures called Good Manufacturing Practices (GMP). In Brazil, the National Sanitary Surveillance Agency (ANVISA) regulates the GMP production of medicines through RDC17/2010 and for radiopharmaceuticals through RDC 63/2009 and 38/2008, to ensure their safe and correct use in commercial production and nuclear medicine services, respectively. Most 99mTc radiopharmaceutical monographs have biological distribution specifications. Using invasive method, 99mTcradiopharmaceuticalsare assessed by the injection into animals of defined strains and the radioactivity (as percentage of retainedor injected dose -%RDor%ID)ismeasured in specified organs. Technetium-99m Sestamibi radiopharmaceutical (99mTc-2-methoxy-isobutyl-isonitrile; 99mTc-sestamibi; MIBI-TEC®) monograph is related in USP 41, but the biological distribution assay is not included. At IPEN, the biodistribution test is performed as established in the Radiopharmaceutical Quality Control Manual of ARCAL XV (1999) - International Atomic Energy Agency (IAEA), for each batch. The objective of this work is to compare MIBI-TEC®biodistribution results using dose calibrator and gamma counter with sodium iodide detector by measuring the radioactivity in the organs. Three batches of MIBI-TEC®were used and 1 vial of lyophilized reagent (LR) was labeled with 5-10 mCiin 1-3 mL of 99mTc eluate. 200-300 μCi in 0.2 mLwereinjected in 3 Balb-Cmice. After 30 minutes of biodistribution, heart, lung, muscle, liver, paw, column and tail were withdrawn, weighed and radioactivity was measured in dose calibrator and gamma counter (μCi andcpm, respectively). %ID/g ratio in the organs of interest was calculated using the data obtained by both equipment and the results were compared. No significant differences were observed and it was possible to conclude that either a dose calibrator or a gamma counter can be used in the routine of quality control.
A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.
✔ É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do
Buscar no Repositório
, isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.
✔ A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em
Navegar
✔ Os filtros disponíveis em
Navegar
tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro,
Autores IPEN
apresenta uma relação com os autores vinculados ao IPEN; o
ID Autor IPEN
diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome;
Tipo de acesso
diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.
A opção
Busca avançada
utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.
Exemplo:
Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.
Autor: Maprelian
Título: loss of coolant
Tipo de publicação: Texto completo de evento
Ano de publicação: 2015
✔ Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA, por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.
✔ 95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN,
bibl@ipen.br
.
✔ Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.
✔ O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.
✔ Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.
✔ Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).
ATENÇÃO!
ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI,
clique aqui.
2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI,
clique aqui.
O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.
Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.