SAVI, MATHEUSBERTONCINI, MARCO A.POTIENS, MARIA da P.A.2020-03-312020-03-31SAVI, MATHEUS; BERTONCINI, MARCO A.; POTIENS, MARIA da P.A. Commercial filament testing for use in 3D printed phantoms. In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 3rd, May 27-31, 2019, Lisboa, Portugal. <b>Abstract...</b> Lisboa, Portugal: C2TN, Instituto Superior Técnico, Universidade de Lisboa, 2019. Disponível em: http://repositorio.ipen.br/handle/123456789/31011.http://repositorio.ipen.br/handle/123456789/31011Introduction With the popularization of 3D printing, many areas of knowledge are using this technology to create products and diminish costs, even in health segment. Commercial phantoms are expensive and hard to obtain in development countries. As alternative, 3D printed phantoms can be the way to produce inexpensive and reliable simulators aimed for dosimetry and teaching. That said, the objective of this study is to determine which of the available commercial fi laments can be used in 3D printing to mimic human tissue for use in 3D printed phantoms. Methods Fourteen 3D printing fi laments (ABS, ABS premium, PLA, PLA+Bone, PLA+aluminum, PLA+brass, PLA+cooper, SILK, HIPS, PETG, PVA, Wood, TPU and TPE) commercially available in Brazil had their attenuation tested, using computed tomography. Each material was printed as 2 centimeters edge cube with rectilinear pattern and 60, 80 and 100 percent infi ll. The cubes were scanned in a Philips CT Brilliance 6 with 120 kV, 200 mA, 2mm slices and standard reconstruction. At the center of each cube, an ~ 120 mm² region of interest were set to measure the mean Hounsfi eld Unit (HU) and the standard deviation value. For each material a graphic was plotted and the curve equation determined. Results The HU of the tested materials ranged from -516,2 ± 7,3 to 329,8 ± 18,9. All human tissues could be mimetized with these materials, except bone (mainly cortical bone). Considering the curve equation, the most promising fi lament was PLA+Cooper, due to the multiple infi ll confi guration that allows the resulting HU range to represent from adipose and skin tissue to marrow bone. With a two extruder printer may be possible add lung tissue to the model and make a 3D phantom more complex and accurate. Conclusions With these tested materials, is possible to construct various phantoms, simulating a wide range of tissues. However, any simulator with cortical bone is impaired because none fi lament achieve the required HU value (at least over 800 HU).openAccess3d printingphantomsfabricationfilamentsradiologycomputerized tomographyCommercial filament testing for use in 3D printed phantomsResumo de eventos científicos0000-0002-4049-6720https://orcid.org/0000-0002-4049-6720