REJANE MARIA PEREIRA DA SILVA

Projetos de Pesquisa
Unidades Organizacionais
Cargo

Resultados de Busca

Agora exibindo 1 - 10 de 11
  • Artigo IPEN-doc 29682
    Investigação da atividade eletroquímica de liga Al-Cu-Li após processo de soldagem por fricção e mistura
    2023 - SILVA, REJANE M.P. da; MILAGRE, MARIANA X.; ARAUJO, JOAO V. de S.; RAMIREZ, OSCAR M.P.; MACHADO, CARULINE de S.C.; ANTUNES, RENATO A.; COSTA, ISOLDA
    In this work, the local electrochemical activity of the zones coupled by Friction Stir Welding (FSW) of an Al-Cu-Li alloy was studied and the results were correlated to the microstructural characteristics of each zone. Electrochemical studies were carried out in the zones affected by welding using cyclic voltammetry (CV) and scanning electrochemical techniques (namely, SECM - Scanning Electrochemical Microscopy and LEIS – Local electrochemical impedance spectroscopy). The results showed that the welding joint (WJ) is predominantly cathodic relatively to the heat affected zones (HAZ). The HAZ was always anodic and showed the highest electrochemical activities among the tested ones. The high electrochemical activity of the HAZ was associated with the effect of galvanic coupling between the cathodic region (WJ) and the anodic region (HAZ). In addition, the advancing side (AS) presented increased electrochemical activity compared to the retreating one (RS).
  • Artigo IPEN-doc 28885
    Compreendendo os mecanismos de corrosão de ligas de Al-Cu-Li
    2022 - ARAUJO, JOAO V. de S.; SILVA, REJANE M.P. da; VIVEIROS, BARBARA V.; MILAGRE, MARIANA X.; MACHADO, CARULINE de S.C.; COSTA, ISOLDA
    In this study, the corrosion mechanism of an Al-Cu-Li alloy manufactured by two different treatment routes (T3 and T851) was evaluated by immersion and electrochemical tests in solutions containing chloride ions (Cl-). For both alloys, the formation of cavities on the surface was associated with micrometer-sized intermetallics (IM’s), however, in addition to this attack, the alloy submitted to T851 treatment also presented an attack called severe localized corrosion (SLC), caused by the preferential attack to the nanometric T1 (Al2CuLi) phase. The electrochemical concepts involved in these two types of attacks were discussed. During the IM’s corrosive process, whereas the O2 reduction occurred over the IM’s, the Al dissolution is favored around the particle, forming trenching and cavities (with 2 and 6 mm of depth). On the other hand, the mechanism associated with the SLC is related to the formation of a differential aeration cell followed by the evolution of H2, with greater depth of attack penetration (8 and 35 mm). Additionally, by the use of the Scanning Vibrating Electrode Technique (SVET), it was concluded that the higher anodic currents observed for the T851 temper were related to the relation between the anodic area (Aa) and the cathodic area (Ac).
  • Artigo IPEN-doc 28531
    Influence of chloride ions concentration on the development of severe localised corrosion and its effects on the electrochemical response of the 2198-T8 alloy
    2021 - MACHADO, CARULINE de S.C.; SILVA, REJANE M.P. da; ARAUJO, JOAO V. de S.; MILAGRE, MARIANA X.; DONATUS, UYIME; VIVEIROS, BARBARA V.G. de; KLUMPP, RAFAEL E.; COSTA, ISOLDA
    The development of severe localised corrosion (SLC) on the 2198-T8 alloy was investigated in solutions of various NaCl concentrations (0.001, 0.005 and 0.01 mol L−1). Immersion tests, optical profilometry, conventional and local electrochemical analyses were performed to evaluate the corrosion behaviour of the alloy. Immersion tests showed that the alloy is susceptible to SLC in all conditions, although the pits sizes were dependent on the solution concentration. The largest anodic areas, corresponding to SLC sites, were observed for the sample immersed in 0.001 mol L−1 NaCl, whereas pits with similar sizes were observed for the samples immersed in solutions with 0.005 and 0.01 mol L−1 of NaCl. Moreover, the maximum depth of attack was observed for the sample immersed in 0.001 mol L−1 NaCl. These results were in agreement with the scanning ionselective electrode technique (SIET) maps which showed stronger acidification on the sample exposed to 0.001 mol L−1 NaCl solution.
  • Artigo IPEN-doc 27712
    Corrosion protection of the AA2198-T8 alloy by environmentally friendly organic-inorganic sol-gel coating based on bis-1,2-(triethoxysilyl) ethane
    2021 - KLUMPP, RAFAEL E.; DONATUS, UYIME; SILVA, REJANE M.P. da; ANTUNES, RENATO A.; MACHADO, CARULINE de S.C.; MILAGRE, MARIANA X.; ARAUJO, JOAO V. de S.; VIVEIROS, BARBARA V.G. de; COSTA, ISOLDA
    In this work, a surface coating composed of organic‐inorganic hybrid sol‐gel based on bis‐1,2‐(triethoxysilyl) (BTSE) ethane was applied on AA2198‐T8 samples, and its effect on corrosion resistance was investigated and compared with that of a chromate layer formed in a solution with hexavalent chromium ions. The corrosion resistance of BTSE coated samples was evaluated by immersion tests in sodium chloride solution (0.005 mol/L NaCl) and monitored by global electrochemical techniques such as electrochemical impedance spectroscopy (EIS) and local electrochemical techniques such as scanning vibrating electrode technique (SVET) and scanning electrochemical microscopy (SECM). The formed coating layers were characterized by X‐ray photoelectron spectroscopy (XPS). The results pointed out that the BTSE is an effective alternative coating for corrosion protection of new generation Al‐Cu‐Li alloys and could replace chromates obtained in toxic and carcinogenic CrVI containing solutions leading to improved corrosion protection.
  • Artigo IPEN-doc 27686
    Mecanismo de evolução de hidrogênio durante a corrosão da liga 2198-T8 em meio contendo cloreto
    2020 - ARAUJO, JOAO V. de S.; SILVA, REJANE M.P. da; MILAGRE, MARIANA X.; MACHADO, CARULINE de S.C.; COSTA, ISOLDA
    Corrosion is still one of the most serious and frequent problems in industries. The phenomena involved in the corrosion mechanism of Al-alloys may be explained by formation of galvanic cells between the metal matrix and heterogeneities, such as precipitates, intermetallic phases leading to potential differences and electrochemical reactions. In the cathodic sites, the main reactions are oxygen reduction reaction, in aerated neutral environments, and hydrogen evolution in acid media. This last type of reaction might also occur in neutral solutions inside pits (anodic region). In this study, the mechanism of hydrogen evolution during corrosion of the 2198-T8 Al-Cu-Li alloy exposed in a chloride solution was investigated. The mechanism was related to the presence of T1 phase (Al2CuLi), which is the main strengthening phase in this material. This phase is highly active and, when exposed to corrosive media, leads to severe localized corrosion (SLC). One of the main characteristics related to SLC is hydrogen gas evolution which was confirmed by gel visualization. In this study, the hydrogen evolution mechanism inside the SLC sites was studied by scanning electrochemical microscopy (SECM).
  • Artigo IPEN-doc 27402
    Microstructural, electrochemical and localized corrosion characterization of the AA2198-T851 alloy
    2020 - ARAUJO, JOAO V. de S.; SILVA, REJANE M.P. da; DONATUS, UYIME; MACHADO, CARULINE de S.C.; COSTA, ISOLDA
    In the present work, the microstructure, electrochemical behavior and localized corrosion of the AA2198-T851 Al-Cu-Li alloy were studied. The microstructure was correlated with corrosion results obtained by immersion, gel visualization and scanning electrochemical microscopy (SECM) tests. Immersion and gel visualization tests showed high kinetics of corrosion attack during the first hours of immersion. SECM analyzes by means of surface generation/tip collection (SG/TC) mode detected hydrogen evolution generated during spontaneous corrosion from severe localized corrosion (SLC) sites on the metal surface. SECM results revealed sites of intense hydrogen evolution after 2 h of immersion and increased amounts of corrosion products after 4 h of immersion. Hydrogen evolution sites detected by SECM were associated with severe localized corrosion (SLC).
  • Artigo IPEN-doc 27391
    Galvanic coupling effects on the corrosion behavior of the 6061 aluminum alloy used in research nuclear reactors
    2020 - MILAGRE, MARIANA X.; DONATUS, UYIME; SILVA, REJANE M.P.; BETANCOR-ABREU, ABENCHARA M.; RAMIREZ, OSCAR M.P.; MACHADO, CARULINE S.C.; ARAUJO, JOAO V.S.; SOUTO, RICARDO M.; COSTA, ISOLDA
    The 6061 alloy is used in different thermomechanical conditions in research nuclear reactors. Nuclear fuel plates are manufactured by the picture frame technique (PFT) and the 6061 alloy is used as cladding for the nuclear fuel “sandwiches”. After the PFT process, these nuclear plates are placed in a case made of 6061-T6 alloy. In this work, the galvanic effects of coupling the 6061 alloy in the T6 and PFT temper conditions were investigated in different chloride-containing solutions. The results showed that galvanic coupling was favored between the PFT and 6061-T6 alloy. A potential difference of about 50 mV was observed between the temper conditions. This was attributed to differences in β’’ phase density between the two conditions (T6 and PFT) which was indicated by microhardness results. The 6061 alloy in the PFT condition was cathodic in relation to the T6 one. Results from conventional electrochemical techniques were in agreement with the local measurements. Local electrochemical techniques such as the SVET, SECM and LEIS were useful in characterizing the electrochemical behavior of the galvanically coupled alloys.
  • Artigo IPEN-doc 27178
    Galvanic and asymmetry effects on the local electrochemical behavior of the 2098-T351 alloy welded by friction stir welding
    2020 - MILAGRE, MARIANA X.; DONATUS, UYIME; MOGILI, NAGA V.; SILVA, REJANE M.P.; VIVEIROS, BARBARA V.G. de; PEREIRA, VICTOR F.; ANTUNES, RENATO A.; MACHADO, CARULINE S.C.; ARAUJO, JOAO V.S.; COSTA, ISOLDA
    Scanning electrochemical microscopy (SECM) and scanning vibrating electrode technique (SVET) were used to investigate the electrochemical behaviour of the top surface of the 2098-T351 alloy welded by friction stir welding (FSW). The SVET technique was efficient in identifying the cathodic and anodic weld regions. The welding joint (WJ), which comprises the thermomechanically affected zone (TMAZ) and the stir zone (SZ), was cathodic relative to the heated affected zone (HAZ) and the base metal (BM). The reactivities of the welding joint at the advancing side (AS) and the retreating side (RS) were analyzed and compared using SECM technique in the competition mode by monitoring the dissolved oxygen as a redox mediator in 0.005 mol L−1 NaCl solution. The RS was more electrochemically active than the AS, and these results were correlated with the microstructural features of the welded alloy.
  • Artigo IPEN-doc 26644
    Macro and microgalvanic interactions in friction stir weldment of AA2198-T851 alloy
    2019 - DONATUS, UYIME; SILVA, REJANE M.P. da; ARAUJO, JOAO V. de S.; MILAGRE, MARIANA X.; ABREU, CAIO P. de; MACHADO, CARULINE de S.C.; COSTA, ISOLDA
    The galvanic interactions within and between the friction stir weld zones of the AA2198-T851alloy have been investigated using electrochemical and microscopy techniques. The parentmaterial (PM) was the most anodic region and exhibited pronounced severe localized corro-sion (SLC) both when coupled and isolated. The stir zone was the most resistant to corrosionand exhibited no SLC when coupled, but exhibited SLC when isolated. Profiles associatedwith dissolved oxygen consumption and hydrogen generation currents across the weldmentwere inversely related because the anodic (PM) region produced higher hydrogen bubblesand, interestingly, consumed more dissolved oxygen compared with the other regions.
  • Artigo IPEN-doc 26643
    Exfoliation corrosion susceptibility in the zones of friction stir welded AA2098-T351
    2019 - MILAGRE, MARIANA X.; DONATUS, UYIME; MACHADO, CARULINE S.C.; ARAUJO, JOAO V.S.; FERREIRA, RAPHAEL O.; SILVA, REJANE M.P.; ANTUNES, RENATO A.; COSTA, ISOLDA
    In the present study, the exfoliation susceptibility of the weld zones in friction stir weldedAA2098-T351 was compared with that of the base metal (BM) according to ASTM G34 stan-dard practice. Friction stir welding (FSW) had a significant effect on the microstructure of theAl alloy tested and the susceptibility to exfoliation was strongly affected by the microstruc-ture. Different features of corrosion attack and exfoliation susceptibility were observed whenthe zones affected by FSW were tested isolated or coupled. Also, the near-surface deformedlayer had an important effect on the Al alloy susceptibility to exfoliation. These are themain findings of this work. The corrosion features were correlated with the microstructuralmodifications related to the welding process and with the electrochemical response. TheT1 phase morphology, distribution and size were critical for exfoliation susceptibility. Thestir zone (SZ) was the zone most resistant to exfoliation. However, resistance to exfoliationvaried with the temperatures reached in the heat affected zones (HAZs). The HAZ exposedto the lowest temperatures during welding, HAZ (LT), was the most susceptible to exfoli-ation, whereas the HAZ exposed to the highest temperatures, HAZ (HT), presented highresistance to exfoliation, similarly to the SZ. The ASTM-G34 practice was an effective anduseful method in identifying the different exfoliation resistances of the BM and the vari-ous zones affected by FSW. The results of this practice were supported by electrochemicalimpedance spectroscopy (EIS) tests.