MARINA FALLONE KOSKINAS

Resumo

Graduate at Física from Pontifícia Universidade Católica de São Paulo (1972), master's at Nuclear Engineering from Universidade de São Paulo (1978) and ph.d. at Nuclear Engineering from Universidade de São Paulo (1988). Has experience in Nuclear Engineering, focusing on Instrumentation for Measure and Control of Radiation, acting on the following subjects: radionuclide metrology, standardizations in coincidence system, determination of nuclear parameters, gamma emission probability per decay. (Text obtained from the Currículo Lattes on November 17th 2021)


Possui graduação em Física pela Pontifícia Universidade Católica de São Paulo (1972), mestrado em Tecnologia Nuclear pela Universidade de São Paulo (1978) e doutorado em Tecnologia Nuclear pela Universidade de São Paulo (1988). Atualmente é pesquisador titular do Instituto de Pesquisas Energéticas e Nucleares. Tem experiência na área de Engenharia Nuclear, com ênfase em Instrumentação para Medida e Controle de Radiação, atuando principalmente nos seguintes temas: metrologia de radionuclídeos, padronização em sistemas de coincidências, determinação de parâmetros nucleares como probabilidade de emissão gama por decaimento. (Texto extraído do Currículo Lattes em 17 nov. 2021)

Projetos de Pesquisa
Unidades Organizacionais
Cargo

Resultados de Busca

Agora exibindo 1 - 2 de 2
  • Artigo IPEN-doc 29810
    k0‑IPEN
    2023 - DIAS, MAURO da S.; SEMMLER, RENATO; KOSKINAS, MARINA F.; MOREIRA, DENISE S.; YAMAZAKI, IONE M.; BRANCACCIO, FRANCO; BARROS, LIVIA F.; RIBEIRO, RAFAEL V.; MORAIS, THALES S.L. de
    A software package for INAA (Instrumental Neutron Activation Analysis), developed at the Nuclear Metrology Laboratory of the IPEN-CNEN/SP, called k0-IPEN, is described. The package consists of a main program linked to nine subprograms designed to perform automatically most of the tasks necessary in order to obtain the mass fractions of the irradiated samples. External efficiency curves calculated by the Monte Carlo code MCNP6 can be read to extend the calibration curve to source to detector distances where only a few experimental points are available. Covariance analysis was used in all steps of the calculation. The validation of the code was tested in an intercomparison sponsored by the IAEA.
  • Resumo IPEN-doc 28957
    k0-IPEN
    2022 - DIAS, MAURO da S.; SEMMLER, RENATO; KOSKINAS, MARINA F.; MOREIRA, DENISE S.; YAMAZAKI, IONE M.; BRANCACCIO, FRANCO; BARROS, LIVIA F.; RIBEIRO, RAFAEL V.; MORAIS, THALES S.L. de
    A new software package for INAA, developed at the Nuclear Metrology Laboratory (LMN) of the Nuclear and Energy Research Institute (IPEN-CNEN/SP), called k0-IPEN, is described. The package consists of a main program linked to nine subprograms designed to perform automatically all the tasks necessary in order to obtain the mass fractions of the irradiated samples. The goals of these nine routines are: a) to calculate the experimental peak efficiencies and P/T ratios for the standard sources, together with all the corresponding uncertainties; b) to correct the peak efficiencies for coincidence summing; c) to fit the peak efficiencies and P/T ratios with log-log polynomial functions; d) to determine experimentally the  and f parameters by the Triple Bare and by the Cd Ratio Multimonitor Methods; e) to correct for interferences; f) to determine the average mass fractions, taking into account the correlations among all partial uncertainties involved. In the present version, the only data that must be inserted as input parameter, externally from the package, are the self-shielding correction factor, which is calculated by the MATSSF code, and the geometry factor that corrects for the difference between sizes of standard sources and measured samples. The code can deal with different spectrum formats such as CHN, SPE and CNF. The routine designed to calculate the peak areas has a simple algorithm and is not yet capable of separating multiplets. Therefore, it is suitable for analysing separated peaks, such as those found in standard calibration source measurements. However, for complex spectra, the code can read peak list files obtained from other codes, such as HyperMet or HyperLab. External efficiency curves calculated by the Monte Carlo code MCNP6 can be read to extend the calibration curve to regions where there are only a few experimental points available. The code k0-IPEN is being tested and its validation accomplished by means of an intercomparison sponsored by the IAEA, and presented at this conference.