DAIANE CRISTINI BARBOSA DE SOUZA

Projetos de Pesquisa
Unidades Organizacionais
Cargo

Resultados de Busca

Agora exibindo 1 - 10 de 12
  • Artigo IPEN-doc 27743
    Gamma spectrometry of iodine-125 produced in IEA-R1 nuclear reactor, using HPGe detector and fixation into epoxy matrix disc
    2021 - COSTA, OSVALDO L. da; SOUZA, DAIANE C.B. de; CASTANHO, FABIO G.; FEHER, ANSELMO; MOURA, JOÃO A.; SOUZA, CARLA D.; OLIVEIRA, HENRIQUE B.; MADUAR, MARCELO F.; ZEITUNI, CARLOS A.; ROSTELATO, MARIA E.C.M.
    Few places in the world produce iodine-125. In Brazil, the first production was achieved by using the IEA-R1 nuclear reactor located at Nuclear and Energy Research Institute – IPEN. To verify the quality of iodine-125 produced, and the amount of contaminants such as iodine-126, cesium-134 and caesium-137 among others, iodine-125 samples were immobilized into epoxy matrix disc, with the same geometry of a barium-133 reference radioactive source, used to calibrate an HPGe detector. The HPGe detector has a thin carbon composite window, which allows measure the iodine-125 photopeaks, between 27.1 and 35.4 keV. The method employed here was successful in producing and measurement of iodine-125.
  • Resumo IPEN-doc 27037
    Waste management protocols for Iridium-192 sources production laboratory used in cancer treatment
    2016 - ROSTELATO, MARIA E.C.M.; SOUZA, CARLA D. de; SOUZA, DAIANE C.B. de; ZEITUNI, CARLOS A.; TIEZZI, RODRIGO; COSTA, OSVALDO L. da; RODRIGUES, BRUNA T.; MOURA, JOÃO A.; FEHER, ANSELMO; SORGATTI, ANDERSON; MOURA, EDUARDO S. de; MARQUES, JOSE R. de O.; SANTOS, RAFAEL M. dos; KARAM JUNIOR, DIB
    Introduction: Brachytherapy is a form of treatment that uses radioactive seeds placed in contact or inside the region to be treated, maximizing the radiation dose inside the targeted areas. Iridium-192 is being used in brachytherapy since 1955. It presents emission energy in the “therapy region” (370keV) and is easily produced in a nuclear reactor (191Ir (n, γ) → 192Ir). Wires are an iridium-platinum alloy with 0.36 mm diameter and they can be cut in any needed length. They can be used in several types of cancer. The linear activity is between 1 mCi/cm (37 MBq/cm) and 4 mCi/cm (148 MBq/cm) with variations of 10% in 50 cm maximum. This activity values classified the treatment and low dose rate (0,4 à 2 Gy/h). The propose of this work is to present a waste management system in a cancer treatment radioactive sources production laboratory. Methodology and Results: The solid waste is previously characterized in the analysis phase. The contaminants are already known and they are insignificant due to their fast half- life. The iridium-192 half-life is 74.2 days, classified as very short half-life waste. The waste activity is adds to 8mCi (2.96x108 Bq) per wire. According to the CNEN-NN 6.08 standard, that presents the discharge levels, the limit is 1 kBq.kg-1 (2.7x10-5 mCi.kg-1). The radioactive waste generated during the I192 wires production has a weakly activity of 9.7 GBq.g-1. According to the standards, this activity is too high to be discarded into the environment. The waste must be managed following the ALARA principal using the R&R (retain e retard) system, that means, temporary storage and posterior discharge. Since every 4 months, maintenance is performed inside the hot cell used for production, the waste must be removed. Using the equation: 𝐴 = 𝐿 λ (1 − 𝑒−λt), the total calculated activity is 1.68 x 1016 Bq and 4.8 g mass at the end of each 4 months period. This amount is stored inside a shielding device that has 212.37 cm3 volume. The waste will take 9.8 years (calculated by 𝐴 = 𝐴0(𝑒−λt)) to decay to the discharge levels. To store 30 devices during 10 years, a space with 6,370 cm3 is necessary. The laboratory has enough space for this storage. Thus, the radioactive waste management can be performed through the R&R (retain and retard) system safely.
  • Artigo IPEN-doc 26206
    Gamma spectrometry of iodine-125 produced in IEA-R1 nuclear reator, using HPGe detector and fixation into epoxy matrix disc
    2019 - COSTA, OSVALDO L. da; SOUZA, DAIANE C.B. de; CASTANHO, FABIO G.; FEHER, ANSELMO; MOURA, JOÃO A.; SOUZA, CARLA D. de; OLIVEIRA, HENRIQUE B. de; MADUAR, MARCELO F.; ZEITUNI, CARLOS A.; ROSTELATO, MARIA E.C.M.
    Few places in the world produce iodine-125. In Brazil, the first production happened in nuclear reactor IEA-R1 located at Nuclear and Energy Research Institute – IPEN. To verify the quality of iodine-125 produced, because contaminants as iodine-126, caesium-134 and caesium-137 among others, may be produced in irradiation process, iodine-125 samples were immobilized into epoxy matrix disc, with the same geometry of a barium-133 reference radioactive source, used to calibrate an HPGe detector. The HPGe detector has a thin carbon composite window, which allows measure the iodine-125 photopeaks, between 27.1 and 35.4 keV.
  • Artigo IPEN-doc 24424
    Evaluation of Exhaust System for Gaseous Waste from the Source Production Laboratory for Radiotherapy – IPEN
    2017 - SOUZA, D.C.B. de; COSTA, O.L.; FEHER, A.; GERALDO, B.; CARVALHO, V.S.; BARBOSA, N.K.O.; VICENTE, R.; ZEITUNI, C.A.; ROSTELATO, M.E.C.M.
    Exhaust systems in fume hood for chemicals and hazardous materials as radioactive substances are of great importance for the protection of the Occupationally Exposed Individual and the environment. They protect against external contam-inations by particulate matter, volatile and against inhalation of radioactive gases. This work intends to evaluate the exhaustion system of the Laboratory of Production of Radioactive Sources at the Nuclear and Energy Research Institute (IPEN).
  • Artigo IPEN-doc 24374
    Waste management protocols for iridium-192 sources production laboratory used in cancer treatment in Brazil
    2017 - ROSTELATO, M.E.C.M.; SOUZA, D.C.B.; SOUZA, C.D.; ZEITUNI, C.A.; VICENTE, R.; COSTA, O.L.; RODRIGUES, B.T.; MOURA, J.A.; FEHER, A.; MOURA, E.S.; MARQUES, J.R.O.; CARVALHO, V.S.; NOGUEIRA, B.R.
    Objective: The iridium-192 wired sources production results in radioactive waste that needs to follow the guidelines. The aim of this study is to do a radioactive waste management of wastes from iridium-192 sources production laboratory used in cancer treatment in Brazil. Methods: The wire is acquired in an alloy form with 80% platinum and 20% iridium encapsulated with 100%. Electronic microscopy, X-ray fluorescence, and posterior iridium neutron activation (to determine contaminants) are performed to ensure quality. A 50-cm twisted wire is placed in an aluminum tube. The tube is sealed and place inside the reactor irradiator system and is left for decay during 30 hours to wait for the others undesired activation products to decay. The wire is prepared for treatment with 48 cm length with 192 mCi maximum activity. All the equipment use inside the hot cell must be calibrated every four months. All the waste must be removed from the hot cell. Results: The solid waste is previously characterized in the analysis phase. The contaminants are already known and they are insignificant due to their fast half-life. The iridium-192 half-life is 74.2 days, classified as very short half-life waste. The reminiscent activity is 8mCi. Conclusion: The radioactive waste generated during the I192 wires production is solid, was a short half-life and a weakly activity of 9.7 GBq.g-1. According to the standards, this activity is too high to be discarded into the environment (limit 10 Bq.g-1). The waste must be managed by the R&R (retain e retard) system.
  • Artigo IPEN-doc 24133
    Brazilian demand for iodine-125 seeds in cancer treatment after a decade of medical procedures
    2017 - COSTA, OSVALDO L. da; SOUZA, DAIANE C.B. de; FEHER, ANSELMO; MOURA, JOAO A.; SOUZA, CARLA D.; OLIVEIRA, HENRIQUE B. de; PELEIAS JUNIOR, FERNANDO S.; ZEITUNI, CARLOS A.; ROSTELATO, MARIA E.C.M.
  • Resumo IPEN-doc 23458
    Brazil radioactive sources production for cancer treatment
    2016 - ROSTELATO, MARIA E.; SOUZA, CARLA D.; ZEITUNI, CARLOS A.; MOURA, JOAO A.; MARQUES, JOSE R.O.; COSTA, OSVALDO L.; FEHER, ANSELMO; RODRIGUES, BRUNA T.; SOUZA, DAIANE C.B. de; PELEIAS JUNIOR, FERNANDO S.; SORGATTI, ANDERSON; MOSCA, RODRIGO; MOURA, EDUARDO S. de; ABREU, RODRIGO T.; SOUZA, RAQUEL V. DE; NOGUEIRA, BEATRIZ R.
    The modality, known as brachytherapy, was performed in Brazil by only a hand full of hospitals at an extremely high cost. For producing new sources, five major areas must be considered: 1) source production: nuclear activation and/or radiochemical reaction; 2) welding; 3) Quality control: leakage tests; 4) Dosimetry and metrology; 5) Operational procedures; 6) validation studies. To perform all steps, a multidisciplinary team works together to overcome difficulties. - Iridium-192 pellets: In Brazil there are 140 machines with pellets that replacement every 5 years. Our new production line has assembly, welding and quality control hot cells. - Iridium-192 wires: Produced since 1999. The wire is activated at IPENs IEA-R1 reactor for 30 hours with 5x1013 n/cm-2.s-1 neutron flux resulting in 192 mCi maximum activity. - Iridium-192 seed: New seed for ophthalmic cancer treatment. The irradiation device presented 90% activity homogeneity. We are still testing in-vivo. - Iodine-125 seeds: Largely used in low dose brachytherapy. I-125 binding yield achieved with our new reaction was 80%; Laser welding presented 70% efficiency. Approved in all leakage tests. - Other ongoing projects: Veterinary brachytherapy, Waste management, Radionecrosis healing with laser, calibrations sources production, linear accelerator calculations for hospitals, sources with polymeric matrix Our Iodine-125 seeds will be available in 2018. All other projects are advancing. We will continue to develop new products hoping to help the Brazilian population fight against cancer. For producing new sources, five major areas must be considered: 1) source production: nuclear activation and/or radiochemical reaction; 2) welding; 3) Quality control:eakage tests; 4) Dosimetry and metrology; 5) Operational procedures; 6) validation studies. To perform all steps, a multidisciplinary team works together to overcome difficulties
  • Artigo IPEN-doc 22887
    Surface coating and study of metallic cores for radioactive sources production used in cancer treatment
    2016 - ROSTELATO, M.E.C.M.; SOUZA, C.D.; ZEITUNI, C.A.; MATTOS, F.R.; MARQUES, J.R.O.; MOURA, J.A.; FEHER, A.; COSTA, O.L.; SOUZA, D.C.B.; TIEZZI, R.; RODRIGUES, B.T.; KARAM JUNIOR, D.
    Developing new and innovative treatments for cancer is an urgent matter. The National Institute of Cancer estimates that Brazil will have 576,000 new cases of the disease in 2015. Our research group is developing new radioactive seeds to be use in radiotherapy procedures since the early 2000’s. We present the surface study and research for two of our major projects: iodine-125 seeds for prostate, brain and eye cancer treatment and iridium-192 for eyecancer treatment.
  • Artigo IPEN-doc 22420
    Comparing different methods for radioactive iodine fixation intended for brachytherapy sources manufacture
    2016 - SOUZA, CARLA D.; ROSTELATO, MARIA E.C.M.; ZEITUNI, CARLOS A.; PELEIAS JUNIOR, FERNANDO S.; BENEGA, MARCOS A.G.; MOURA, JOAO A.; FEHER, ANSELMO; COSTA, OSVALDO L.; TIEZZI, RODRIGO; RODRIGUES, BRUNA T.; SILVA, THAIS H. da; SORGATTI, ANDERSON; SOUZA, DAIANE C.B. de
    Brachytherapy, a method of radiotherapy, is being extensively used in the early and intermediate stages of the illness. In this treatment, radioactive seeds are placed inside or next to the area requiring treatment, which reduces the probability of unnecessary damage to surrounding healthy tissues. Currently, the radioactive isotope iodine-125, fixated on silver substrate, is one of the most used in prostate brachytherapy. The present study compares several deposition methods of radioactive iodine on silver substrate, in order to choose the most suitable one to be implemented at the laboratory of radioactive sources production of IPEN. Three methods were selected: method 1 (test based on electrodeposition method, developed by David Kubiatowicz) which presented efficiency of 65.16%; method 2 (chemical reaction based on the method developed by David Kubiatowicz - HCl) which presented efficiency of 70.80%; method 3 (chemical reaction based on the method developed by Dr. Maria Elisa Rostelato) which presented efficiency of 55.80%. Based on the results, the second method is the suggested one to be implemented at the laboratory of radioactive sources production of IPEN.
  • Artigo IPEN-doc 21310
    Study and evaluation of aluminium capsules to irradiation of gaseous samples in nuclear rector
    2015 - COSTA, OSVALDO L. da; FEHER, ANSELMO; MOURA, CARLA D.; TIEZZI, RODRIGO; SOUZA, DAIANE C.B. de; MOURA, EDUARDO S.; OLIVEIRA, HENRIQUE B.; ZEITUNI, CARLOS A.; ROSTELATO, MARIA E.C.M.