  • Resumo IPEN-doc 28121
    Effect of a diode laser irradiation in root canals contamined with Enterococcus faecalis
    2002 - RADAELLI, C.R. de M.; ANTUNES, A.; CAI, S.; ZEZELL, D.M.; GOUW-SOARES, S.
    High success rates were achieved in conventional endodontic treatment of vital pulp teelh. However, in non-vital pulp a decrease of success occurs due to difficulties to achieve a complete disinfection of root canal system. Some bacteria, such as Enterococcus faecalis, are frequently found in endodontic treatment failure due to their high resistance to the usual process of canal shaping and cleaning. The purpose of this work was to evaluate the effectiveness of a diode laser irradiation in bacterial reduction of contaminated canals as well as to analyze the effect of the laser irradiation associated with the use of calcium hydroxide paste. Eighty two root canals infected with Enterococcus faecalis suspension (1x10(6) CFU/ml) were irradiated with a high power diode laser (810nm, Opus 10- Sharplan - Israel) with two different parameters: 2.5W and 3 W (cw), using a 360 μm fiber at an angle of approximately 5 degrees to the dentine surface during 5 seconds in 5 applications, within 20 seconds intervals between. Temperature was monitored at apex using a K-pipe thermocouple. Maximum temperature was 7.45ºC. After these proceedings specimens were vortexed in peptone water and dilutions performed. Aliquots were plated on m-Enterococcus agar. Colonies Forming Units (CFU) of all groups was counted. Statistically the results showed a significant reduction of bacteria on all groups after laser irradiation. A high reduction rate was achieved: 98.5% immediately after laser irradiation; 48 hours after, the reduction rate was 96.73% and finally a 100% reduction was achieved with the association of laser irradiation and calcium hydroxide paste. These high rates of bacteria reduction were achieved using the parameter of 3W (cw), 4.24 KW/cm2. The use of high power diode laser 810nm is highly efficient and suitable to reduce Enterococcus faecalis in infected root canals.
  • Resumo IPEN-doc 10373
    Monitoramento da variacao da temperatura na desinfeccao intracanal com laser de diodo
    2002 - RADAELLI, C.M.; PEREIRA, A.A.; ZEZELL, D.M.; SOARES, S.C.G.
  • Resumo IPEN-doc 09279
    Estudo in vitro de parametros seguros de irradiacao do laser de diodo de alta intensidade no tratamento de condutos radiculares
    2002 - RADAELLI, C.A.R.M.; PEREIRA, A.A.; CAI, S.; ZEZELL, D.M.; SOARES, S.C.G.