  • Artigo IPEN-doc 29833
    Investigation of dosimetric properties of CaSO4:Mn phosphor prepared using slow evaporation route
    2023 - SILVA, ANDERSON M.B.; RODRIGUES, DANIEL S.; ANTONIO, PATRICIA L.; JUNOT, DANILO O.; CALDAS, LINDA V.E.; SOUZA, DIVANIZIA N.
    The objective of this work was to investigate the luminescent properties of CaSO4:Mn synthesized by slow evaporation route. The crystalline structure, morphology, thermal and optical properties of the phosphors were characterized by X-ray diffraction analysis (XRD), Scanning electron microscopy (SEM), photoluminescence (PL) and thermogravimetric analysis (TGA). Moreover, using thermoluminescence (TL) and optically stimulated luminescence (OSL) techniques, the dosimetric properties of the phosphors, such as emission spectra, glow curve reproducibility, dose-response linearity, fading of the luminescent signal, variation of the TL intensity with the heating rate, OSL decay curves, correlation between TL and OSL emissions and minimum detectable dose (MDD) were comprehensively investigated. For dosimetric analyses, the samples were irradiated with doses from 169 mGy to 10 Gy. The emission band fits with the characteristic line of the Mn2+ emission features, ascribed to 6 A1→4 T1 transition. CaSO4:Mn pellets present a TL glow curve with a single typical peak centered around 494 nm, an OSL decay curve with predominance of a fast decay component, and a MDD on the order of mGy. The luminescent signals showed to be linear and reproducible in the studied dose range. The trapping centers located between 0.83 eV and 1.07 eV were revealed for different heating rates in the TL study. The high TL sensitivity of CaSO4:Mn was proven when comparing with commercially available dosimeters. The luminescent signals exhibit a smaller fading than described in the literature for CaSO4:Mn produced by other methods.
  • Artigo IPEN-doc 27772
    Evaluation of high-linearity bone radiation detectors exposed to gamma-rays via FTIR measurements
    2021 - OLIVEIRA, LUCAS N. de; NASCIMENTO, ERIBERTO O. do; MORAIS JUNIOR, PEDRO de A.; ANTONIO, PATRICIA de L.; CALDAS, LINDA V.E.
    In radiation physics, the study of new alternative dosimeters is of interest to the growing branch of dosimetric characterization for radiotherapy applications. The goal of this work was to expose bone samples to high doses and evaluate their linearity response to gamma rays. The Fourier Transform Infrared (FTIR) spectrophotometry technique was employed as the evaluation technique, and based on the spectrophotometry absorbance profiles the linearity was assessed based on the following methods: Area Under the Curve (AUC), Wavenumber Method (WM), Partial Component Regression (PCR) and Partial Least-Square Regression (PLSR) methods. The bone samples were irradiated with absorbed doses of 10 Gy up to 500 Gy using a 60Co Gamma Cell-220 system. The results showed, for the calibration curves of the system, adequate linearity on all methods. In conclusion, the results indicate a good linear response and therefore an interesting potential radiation detector.