IRACI MARTINEZ PEREIRA GONCALVES
15 resultados
Resultados de Busca
Agora exibindo 1 - 10 de 15
Artigo IPEN-doc 27844 Monitoring system for an experimental facility using GMDH methodology2021 - PEREIRA, IRACI M.; MORAES, DAVI A.This work presents a Monitoring System based on the GMDH - Group Method of Data Handling methodology applied in an Experimental Test Facility. GMDH is a combinatorial multi-layer algorithm in which a network of layers and nodes is generated using a number of inputs from the data stream being evaluated. The GMDH method is based on an underlying assumption that the data can be modeled by using an approximation of the Volterra Series or Kolmorgorov-Gabor polynomial. The Fault Test Experimental Facility was designed inspired in a PWR nuclear power plant and is composed by elements that correspond to the pressure vessel, steam generator, pumps of the primary and secondary reactor loops. The nuclear reactor core is represented by an electrical heater with different values of power. The exper-imental plant is fully instrumented with sensors and actuators. The Fault Test Experimental Facility can be operated to generate normal and faulty data. These failures can be added initially with small magnitude, and their magnitude being increasing gradually in a controlled way. The database will interface with the plant supervisory system SCADA (Super-visory Control and Data Acquisition) that provides the data through standard interface.Relatório IPEN-doc 23416 Medida do tempo de resposta de transmissores de pressão da Usina Nuclear de Angra I2017 - PEREIRA, IRACI M.; SANTOS, ROBERTO C. dosNeste relatório são apresentados os resultados de Medida de Tempo de Resposta de cinco transmissores de pressão Rosemount modelo 3154N da Usina Nuclear de Angra I. Os testes foram realizados utilizando-se o Gerador Hidráulico de Rampa e Degrau de Pressão do laboratório de Medidas de Tempo de Resposta de Sensores do CEN – Centro de Engenharia Nuclear do IPEN. Para cada transmissor, foi feito o ajuste de damping para que a constante de tempo fosse menor ou igual a 500 ms. Este valor foi determinado para que o valor total de tempo de resposta da cadeia de proteção não ultrapasse o valor máximo estabelecido de 2 segundos. Para cada transmissor foram feitos dez testes, obtendo-se valores médios de constante de tempo de 499,7 ms, 464,1 ms, 473,8 ms, 484,7 e 511,5 ms, com desvios médios de 0,85%, 0,24%, 0,97%, 1,26% e 0,64% respectivamente.Artigo IPEN-doc 07636 Response time measurement of temperature and pressure sensors of Angra-I nuclear power plant using noise analysis technique2001 - PERILLO, S.R.P.; GONCALVES, I.M.P.; SANTOS, R.C.; TING, D.K.S.Artigo IPEN-doc 07637 Multiple fault detection and isolation using GMDH model2001 - GONCALVES, I.M.P.; UPADHYAYA, B.R.Artigo IPEN-doc 06579 Circuito experimental para pesquisa de sistemas de resfriamento de emergencia de reatores avancados1999 - BAPTISTA FILHO, B.D.; GONCALVES, I.M.P.; ALMEIDA, J.C.; MACEDO, L.A.; SANTOS, S.C.Artigo IPEN-doc 06863 Time response measurement of temperature and pressure sensors of Angra-I nuclear power plant using Noise Analysis Technique2000 - PERILLO, S.R.P.; GONCALVES, I.M.P.; SANTOS, R.C.; TING, D.K.S.Artigo IPEN-doc 02534 Determinacao do tempo de resposta de sensores de temperatura do tipo RTD atraves de medidas 'in situ'1986 - GONCALVES, I.M.P.; SOARES, A.J.Artigo IPEN-doc 18024 Seleção de entradas para redes neurais artificiais usando o algoritmo GMDH2010 - BUENO, ELAINE I.; PEREIRA, IRACI M.; TEIXEIRA e SILVA, ANTONIOArtigo IPEN-doc 18023 Redes neurais e sistemas Fuzzy na monitoração e detecção de falhas em sensores do reator IEA-R12010 - BUENO, ELAINE I.; PEREIRA, IRACI M.; TEIXEIRA e SILVA, ANTONIOArtigo IPEN-doc 04951 Medida do tempo de resposta dos medidores de pressao do SPR da U.N.A.A.A. - Unidade I utilizando o metodo de medida direta1997 - PERILLO, S.R.P.; GONCALVES, I.M.P.; SANTOS, R.C.; SOARES, A.J.; TORRENTES, L.C.S.