CARLA DARUICH DE SOUZA

Resumo

Bsc in Medical Physics from UNESP in Botucatu Compleated at IPEN, University of São Paulo: 1) Master's Degree: Comparison between methods for fixing iodine-125 on silver substrate for fabricating sources used in Brachytherapy / 2) PhD: Parameters for production of iodine-125 sources used in brachytherapy and "sandwich" doctorate: Washington State University - training in radiochemistry and organic chemistry / 3) Post doctorate: Production of nanosources for the treatment of cancer / 4) Project: Analysis of methods to obtain / produce nuclear material for use in a radioisotope thermoelectric generator (RTG)/ Advisor of the Professional Master's Degree in Radiation Technology in Health / Professor of the Professional Master Program in the disciplines Dosimetry for Radiotherapy and Radiotherapy Fundamentals / Professor of the Academic Master Program in the discipline TNA5805 - Brachytherapy: Fundamentals, Production, Application, Dosimetry and Quality Research Associate of KAERI - Korean Atomic Energy and Research Institute (Text obtained from the Currículo Lattes on October 6th 2021)


Formada em Física Médica pela UNESP em Botucatu Realizado no IPEN-USP/ SP: 1) Mestrado: Comparação entre métodos de fixação do iodo-125 em substrato de prata para confecção de fontes utilizadas em Braquiterapia / 2) Doutorado: Parâmetros para produção de confecção de fontes de iodo-125 utilizadas em Braquiterapia e Doutorado sanduíche: Washington State University - treinamento em radioquímica / 3) Pós doutorado: Produção de nanofontes para tratamento de câncer / 4) Projeto: Análise de formas de obtenção/produção do material nuclear para utilização em um gerador termoelétrico radioisotópico (RTG)/ Orientadora do Mestrado Profissional de Tecnologia das Radiações na Saúde/ Professora do Mestrado Profissional nas disciplinas Dosimetria para Radioterapia e Fundamentos de Radioterapia/ Professora do Mestrado Acadêmico na disciplina TNA5805 - Braquiterapia: Fundamentos, Produção, Aplicação, Dosimetria e Qualidade Research Associate do KAERI - Korean Atomic Energy and Research Institute (Texto extraído do Currículo Lattes em 06 out. 2021)

Projetos de Pesquisa
Unidades Organizacionais
Cargo

Resultados de Busca

Agora exibindo 1 - 2 de 2
  • Artigo IPEN-doc 15791
    Analysis of the necessary radioprotection procedures in manufacture of iodine-125 sources used in brachytherapy: A preliminary study
    2011 - SOUZA, CARLA D.; ROSTELATO, MARIA E.C.M.; ZEITUNI, CARLOS A.; MOURA, JOAO A.; MOURA, EDUARDO S.; FONSECA, KATIA; FEHER, ANSELMO
  • Artigo IPEN-doc 19641
    Leakage test methodology development in iodine-125 seeds production
    2013 - MOURA, JOAO A.; SOUZA, CARLA D. de; ROSTELATO, MARIA E.C.M.; MOURA, EDUARDO S. de; SPRENGER, FRANCISCO E.; NAGATOMI, HELIO R.; ZEITUNI, CARLOS A.; FEHER, ANSELMO; MANZOLI, JOSE E.
    Brachytherapy using iodine-125 seeds has been used in prostate cancer treatment. In the quality control routine during seed production, leakage tests are taken to detect any leakage of radioactive material from inside the titanium shield, avoiding patient contamination. Leakage tests are carried out according to the International Standard Organization e Radiation protection e sealed radioactive sources e ISO 9978. This standard recommends different methods of essay applied to radioactive seeds. The aims of this work were the study of the different leakage test methods applied to radioactive seeds recommended by the ISO 9978 and the choice of the appropriate method to be used in the seeds production. The authors evaluated five different immersion methods to detect leakage, following the standard guidance, and in some case exceeding its requirement. One hundred iodine-125 seeds were intentionally cuted, causing the release of its content. Each immersion method was applied to twenty seeds. After the immersion period, the resulting liquid activity was measured. The activity values measured in the immersion liquid indicated best results with distilled water as immersion liquid and with the application of ultrasound to the bath. The temperature of the bath ranged from 20 C to 70 C and the immersion time ranged from 30 min to 24 h. In this experiment, the use of scintillator liquid as immersion liquid was not effective to detect the leakage. The results allow the authors to choose the best methods to be applied in the production routine, to detect leakage in the seeds. The choice of the method will also depend on the production rhythm for schedule. In a moderate production rate, the test at 20 C and 24 h immersion may be used. In a fast production rhythm, the shortest test 50 C or 70 C should be used.