LILIANA CASTRO

Projetos de Pesquisa
Unidades Organizacionais
Cargo

Resultados de Busca

Agora exibindo 1 - 7 de 7
  • Artigo IPEN-doc 25791
    Micro-homogeneity evaluation of a bovine kidney candidate reference material
    2019 - CASTRO, L.; MOREIRA, E.G.; VASCONCELLOS, M.B.A.
    The minimum sample intake for which a reference material remains homogeneous is one of the parameters that must be estimated in the homogeneity assessment study of reference materials. In this work, Instrumental Neutron Activation Analysis was used to evaluate this quantity in a bovine kidney candidate reference material. The mass fractions of 9 inorganic constituents were determined in subsamples between 1 and 2 mg in order to estimate the relative homogeneity factor (HE) and the minimum sample mass to achieve 5% and 10% precision on a 95% confidence level. Results ob-tained for HE in all the analyzed elements were satisfactory. The estimated minimum sample intake was between 2 mg and 40 mg, depending on the element.
  • Tese IPEN-doc 24472
    Preparo e caracterização de um material de referência de rim bovino
    2017 - CASTRO, LILIANA
    A utilização de materiais de referência é uma ferramenta fundamental na obtenção da comparabilidade e rastreabilidade das medições químicas. No presente trabalho foram desenvolvidas todas as etapas necessárias para a preparação, caracterização e certificação de um material de referência de rim bovino segundo os requisitos aceitos internacionalmente. Dado que o uso pretendido do material de referência é o controle de qualidade de produtos cárneos, alguns elementos com relevância nutricional ou que poderiam constituir contaminantes alimentares potenciais foram escolhidos para serem determinados. Foi estudada a homogeneidade do material tanto dentro quanto entre os diversos frascos preparados e a estabilidade do material em diferentes temperaturas e tempos, obtendo resultados satisfatórios. Para poder abarcar todos os elementos de interesse, os estudos de homogeneidade e estabilidade foram realizados utilizando-se três técnicas analíticas diferentes, análise por ativação neutrônica, espectrometria de massa com fonte de plasma acoplada indutivamente e espectrometria de absorção atômica de vapor frio. Para a avaliação dos estudos de homogeneidade e estabilidade foram utilizadas técnicas estatísticas univariadas clássicas como os testes de análise de variâcia e de regressão, e técnicas de análise multivariada como análise de componentes principais e análise de agrupamento hierárquico. Para atribuir valores às concentrações dos elementos de interesse, foi organizada uma comparação interlaboratorial com 33 laboratórios participantes, tanto de Brasil quanto do exterior. A avaliação conjunta dos resultados da comparação interlaboratorial e dos estudos de homogeneidade e estabilidade realizados possibilitou atribuir valores a 20 elementos com suas respectivas incertezas, sendo 9 valores certificados (As, Cu, Fe, K, Mg, Mn, Na, Se e Zn), 10 valores indicativos (Br, Ca, Cd, Cl, Co, Cs, Hf, Mo, P e Rb) e 1 como informação adicional (Hg).
  • Artigo IPEN-doc 24336
    Use of INAA in the homogeneity evaluation of a bovine kidney candidate reference material
    2017 - CASTRO, LILIANA; MOREIRA, EDSON G.; VASCONCELLOS, MARINA B.A.
    Instrumental neutron activation analysis was used to evaluate the between bottle homogeneity and the minimum sample intake of a bovine kidney candidate reference material. The mass fractions of ten inorganic constituents were determined, obtaining satisfactory homogeneity results for all of them. Statistical analysis of the results was performed using a one way analysis of variance and multivariate techniques were applied as complementary techniques, confirming the usefulness of these techniques for homogeneity assessment.
  • Artigo IPEN-doc 24063
    Micro-homogeneity evaluation of a bovine kidney candidate reference material
    2017 - CASTRO, LILIANA; MOREIRA, EDSON G.; VASCONCELLOS, MARINA B.A.
    The minimum sample intake for which a reference material remains homogeneous is one of the parameters that must be estimated in the homogeneity assessment study of reference materials. In this work, Instrumental Neutron Activation Analysis was used to evaluate this quantity in a bovine kidney candidate reference material. The mass fractions of 9 inorganic constituents were determined in subsamples between 1 and 2 mg in order to estimate the relative homogeneity factor (HE) and the minimum sample mass to achieve 5% and 10% precision on a 95% confidence level. Results obtained for HE in all the analyzed elements were satisfactory. The estimated minimum sample intake was between 2 mg and 40 mg, depending on the element.
  • Resumo IPEN-doc 22492
    Use of INAA in the homogeneity evaluation of a bovine kidney candidate reference material
    2016 - CASTRO, LILIANA; MOREIRA, EDSON G.; VASCONCELLOS, MARINA B.A.
  • Resumo IPEN-doc 21369
    Use of multivariate statistical techniques in the homogenity evaluation of a candidate bovine kidney reference material
    2015 - CASTRO, LILIANA; MOREIRA, EDSON G.; VASCONCELLOS, MARINA B.A.
  • Resumo IPEN-doc 20563
    Bovine kidney reference material preparation proposal to be used in quality assurance of chemical measurements in meat products
    2014 - CASTRO, LILIANA; MOREIRA, EDSON G.; MAIHARA, VERA A.; VASCONCELLOS, MARINA B.A.