MARIA DA CONCEICAO COSTA PEREIRA

Resumo

Possui graduação em Química Industrial pela Escola Superior de Química Oswaldo Cruz (1984), Mestrado pelo Instituto de Pesquisas Energéticas e Nucleares - USP (1997) e Doutorado pelo Instituto de Pesquisas Energéticas e Nucleares - USP (2006). Atualmente é pesquisadora do Instituto de Pesquisas Energéticas e Nucleares. Possui experiência na área de Química e Engenharia Nuclear, atuando principalmente nos seguintes temas: detectores de radiação, tempo de decaimento de luminescência, cintilação e crescimento de cristais cintiladores inorgânicos. Orientadora de Mestrado (Texto extraído do Currículo Lattes em 16 nov. 2021)

Projetos de Pesquisa
Unidades Organizacionais
Cargo

Resultados de Busca

Agora exibindo 1 - 3 de 3
  • Artigo IPEN-doc 28297
    Zonal refining and Bridgman technique for CsI:Tl scintillation crystal growth
    2021 - SUZART, K.F.; PEREIRA, M.C.C.; HAMADA, M.M.; MESQUITA, C.H.
  • Artigo IPEN-doc 27921
    Characterization of the CsI(Tl) crystalline scintillating detector produced at IPEN
    2021 - SUZART, K.F.; VELO, A.F.; HAMADA, M.M.; PEREIRA, M.C.C.; MESQUITA, C.H.
    Cesium iodide crystal activated with thallium (CsI(Tl)) is used as radiation sensor because of its favorable characteristics as scintillator, when excited by gamma radiation. This crystal has good mechanical strength and it is relatively little hygroscopic. In the present work, the CsI(Tl) crystal was grown in the Nuclear Energy Research Institute (IPEN/CNEN/SP) by Brigdman technique, in two different formats: (a) cylindric (∅ 20.1 mm x ↑ 11.9 mm) and (b) parallelepiped (12.3 mm x ↑ 19.5 mm). The scintillator spectrometry was studied through five gamma radiation sources: 99mTc (140 keV), 133Ba (355 keV) 22Na (511 keV) and 137Cs (662 keV). The crystals were coupled to a photomultiplier tube using 0.5 McStokes viscosity silicone grease as the optical interface. All electronics for signal measurements were developed at IPEN. Luminescence property of the CsI(Tl) crystal was excited by the radiation from a 137Cs source. The energy resolution of the crystalline detector was determined by the FWHM parameter, corresponding to the photopeak width at half of its height.
  • Artigo IPEN-doc 26199
    Development and characterization of CsI (Tl) crystal for use as a radiation detector
    2019 - SUZART, KAROLINE F.; HAMADA, MARGARIDA M.; PEREIRA, MARIA da C.C.; MESQUITA, CARLOS H. de
    Cesium iodide crystal activated with thallium (CsI(Tl)) is used as radiation sensor because of its favorable characteristics as scintillator when excited by gamma radiation. This crystal has good mechanical strength and it is not hygroscopic. In the present work the CsI(Tl) crystal was growed in the Nuclear Energy Research Institute (IPEN/CNEN/SP) by Brigdman technique in different sizes. The scintillator response was studied through gamma radiation from 99mTc source with the energy of 140 keV. The crystals were coupled to a photomultiplier tube using 0.5 McStokes viscosity silicone grease as the optical interface. All electronics for signal measurements were developed at IPEN. Measurements of luminescence and gamma spectrometry of a 99mTc source were performed. The energy resolution of the crystals was determined by the spectrum photopeak considering its full width at half maximum (FWHM).