  • Resumo IPEN-doc 27010
    Tandem KAP meters calibration parameters by Monte Carlo Simulation using reference RQR radiation qualities
    2016 - POTIENS JUNIOR, ADEMAR; COSTA, NATHALIA; CORREA, EDUARDO; SANTOS, LUCAS; VIVOLO, VITOR; POTIENS, MARIA da P.
    The Kerma-area product quantity can be obtained by measurements carried out with a kerma-area product meter (KAP) with a plane-parallel transmission ionization chamber mounted on the X ray system. It is the integral of the air kerma over the area of the X ray beam in a plane perpendicular to the beam axis. This quantity has been important to establish the diagnostic reference levels (DRLs) all over the word. In this work the MCNP5 code was used to calculate the imparted energy in the air cavity of KAP meter and the spatial distribution of the air collision kerma in entrance plan of the KAP meter. From these data, the air kerma-area product (KAP) and the calibration coefficient for the KAP meter were calculated and compared with those obtained experimentally. The X-ray tube was easily modelled as well the complete tandem calibration set up was possible. The spectra of the diagnostic radiology RQR reference qualities measured were used as a source definition in the input card for the Monte Carlo simulation. The clinical KAP meter calibration coefficients were obtained experimentally and by Monte Carlo simulation. The differences between those values were about 2%, except for RQR 10 (5.45%). The uncertainties in Monte Carlo simulation were less than 0.5% in all cases and the FOM (Figure of Merit) was constant for a number of histories of 1 million.
  • Artigo IPEN-doc 23585
    Mammography calibration qualities establishment in a Mo-Mo clinical system
    2016 - CORREA, E.L.; SANTOS, L.R. dos; VIVOLO, V.; POTIENS, M.P.A.
    In this study the mammography calibration qualities were established in a clinical mammography system. The objective is to provide the IPEN instruments calibration laboratory with both mammography calibration methods (using a clinical and an industrial system). The results showed a good behavior of mammography equipment, in terms of kVp, PPV and exposure time. The additional filtration of molybdenum is adequate, air-kerma rates were determined and spectra were obtained.
  • Artigo IPEN-doc 21582
    Evaluation of a measurements system for uranium electrodeposition control to radiopharmaceuticals production
    2015 - MADI FILHO, TUFIC; SALIBA SILVA, ADONIS M.; CARDENAS, JOSE P.N.; PEREIRA, MARIA da C.C.; LOPES, VALDIR M.; SILVA, ALEXANDRE P.; SANTOS, DIOGO F.; PURGATO, RAFAEL T.; AREDES, VITOR O.; FIGUEREDO, ANDERSON L.; SANTOS, LUCAS R. dos; SANTOS, BRIANNA dos S.; CORREA, EDUARDO L.