NATALIA FIORINI DA SILVA
5 resultados
Resultados de Busca
Agora exibindo 1 - 5 de 5
Resumo IPEN-doc 26061 Simulation of a TH-GEM based detector for standard mammography-quality beam dosimetry using the MCNP5 code2019 - SILVA, N.F.; SILVA, T.F.; CASTRO, M.C.; LUZ, H.N. da; CINTRA, F.B.; CALDAS, L.V.E.Resumo IPEN-doc 26042 Simulation of geometry and materials of the TH-GEM based detector for radiation dosimetry2018 - SILVA, NATALIA F.; SILVA, TIAGO F.; CASTRO, MAYSA C.; LUZ, HUGO N. da; CINTRA, FELIPE B.; CALDAS, LINDA V.E.Resumo IPEN-doc 26038 Evaluation of an extrapolation chamber for dosimetry in computed tomography beams using Monte Carlo code (MCNP5)2018 - CASTRO, MAYSA C.; SILVA, NATALIA F.; SANTOS, LUCAS R.; CINTRA, FELIPE B.; CALDAS, LINDA V.E.Artigo IPEN-doc 24056 Evaluation of the influence of the TH-GEM detector components in dosimetric measurements of standard mammography beams2017 - SILVA, NATALIA F.; SILVA, TIAGO F.; CASTRO, MAYSA C.; CINTRA, FELIPE B.; LUZ, HUGO N. da; CALDAS, LINDA V.E.GEM detectors have found applications in many areas due to their simplicity of construction, low cost, ruggedness and diversity of shape. A dosimeter with these qualities presents utility in several applications, as for example in diagnostic and therapeutic medicine, industrial radiography and nuclear meters. Furthermore, the high sensitivity provided by GEM detectors may extend their applications in low dose dosimetry. Based on these facts, it may be interesting to produce a prototype of a portable TH-GEM type detector with characteristics suitable for dosimetric use in X-rays with low and medium energies. The precise determination of the dosimeter characteristics is very important for laboratories of instrument calibration, as well as to determine how the various components of the detector may influence on the energy deposited in the sensitive volume. In this work, the results obtained about the influence of each one of the components present in this type of detector in standard mammography beams is presented. The code MCNP5 was used. The results allowed the adaptation of the detector to the desired conditions.Artigo IPEN-doc 22684 Determinação do fator de correção para atenuação no ar para uma câmara de ionização de ar livre2016 - SILVA, NATALIA F.; CINTRA, FELIPE B.; CASTRO, MAYSA C. de; CALDAS, LINDA V.E.Este trabalho tem como objetivo apresentar os resultados obtidos experimentalmente e por simulação para o fator de correção da atenuação no ar de uma câmara de ionização de ar livre de cilindros concêntricos Victoreen, modelo 481- 5. Este fator de correção foi obtido para as qualidades padronizadas de mamografia, estabelecidas no Laboratório de Calibração de Instrumentos (LCI) do IPEN. Os valores obtidos foram comparados com os resultados do laboratório padrão primário alemão Physikalisch-Technische Bundesanstalt (PTB), obtendo-se diferenças máximas de 0,40% para o valor experimental e de 0,31% para o valor simulado.