  • Resumo IPEN-doc 26066
  • Artigo IPEN-doc 25078
    Testing an extrapolation chamber in computed tomography standard beams
    2018 - CASTRO, M.C.; SILVA, N.F.; CALDAS, L.V.E.
    The computed tomography (CT) is responsible for the highest dose values to the patients. Therefore, the radiation doses in this procedure must be accurate. However, there is no primary standard system for this kind of radiation beam yet. In order to search for a CT primary standard, an extrapolation ionization chamber built at the Calibration Laboratory (LCI) of the Instituto de Pesquisas Energéticas e Nucleares (IPEN), was tested in this work. The results showed to be within the international recommended limits.
  • Resumo IPEN-doc 24461
    Testing an extrapolation chamber in computed tomography standard beams
    2017 - CASTRO, MAYSA C. de; SILVA, NATALIA F. da; CALDAS, LINDA V.E.
  • Artigo IPEN-doc 24239
    Comparação entre duas câmaras de ionização do tipo lápis com comprimento de volume sensível de 30 cm
    2017 - CASTRO, M.C.; XAVIER, M.; SILVA, N.F.; CALDAS, L.V.E.
    A tomografia computadorizada (CT) vem crescendo devido aos avanços da tecnologia dos equipamentos, proporci-onando uma dose maior no paciente, em relação aos demais exames de radiodiagnóstico, levando a uma preocupa-ção com os pacientes. A dosimetria em CT é realizada com uma câmara de ionização do tipo lápis com comprimen-to de volume sensível de 10 cm. Os estudos têm mostrado a subestimação dos valores de dose. Foram desenvolvidas neste trabalho duas câmaras de ionização com comprimentos de volume sensível de 30 cm, que foram submetidas aos testes principais de caracterização, obtendo-se resultados dentro dos limites recomendáveis internacionalmente. Palavras-chave: Dosimetria, tomografia computadorizada, câmara de ionização especial.
  • Artigo IPEN-doc 24229
    Development and tests of a 30cmpencil-type ionization chamber for dosimetry in standard and clinical CT beams
    2017 - CASTRO, M.C.; SILVA, N.F.; XAVIER, M.; ANDRADE, M.E.A.; KHOURY, H.J.; CALDAS, L.V.E.
    The use of computed tomography (CT) for imaging procedures is growing due to advances in the CT equipment technology. To perform the dosimetry inCT beams, the most widely used instrument is the pencil type ionization chamber with a sensitive volume length of 100 mm; however, some studies have shown that this dosimeter has underestimated the dose values. Therefore, in this study an ionization chamber with sensitive volume length of 300mmwas developed at IPEN. The characterization of this chamber was performed, and the results were obtained within the international recommended limits. As an application, the developed ionization chamber was tested in clinical beams of two different hospitals.
  • Artigo IPEN-doc 24141
    Performance of an extrapolation chamber in computed tomography standard beams
    2017 - CASTRO, MAYSA C.; SILVA, NATALIA F.; CALDAS, LINDA V.E.
    Among the medical uses of ionizing radiations, the computed tomography (CT) diagnostic exams are responsible for the highest dose values to the patients. The dosimetry procedure in CT scanner beams makes use of pencil ionization chambers with sensitive volume lengths of 10 cm. The aim of its calibration is to compare the values that are obtained with the instrument to be calibrated and a standard reference system. However, there is no primary standard system for this kind of radiation beam. Therefore, an extrapolation ionization chamber built at the Calibration Laboratory (LCI), was used to establish a CT primary standard. The objective of this work was to perform some characterization tests (short- and medium-term stabilities, saturation curve, polarity effect and ion collection efficiency) in the standard X-rays beams established for computed tomography at the LCI.
  • Artigo IPEN-doc 22873
    Comparação entre duas câmaras de ionização do tipo lápis com comprimento de volume sensível de 30 cm
    2016 - CASTRO, MAYSA C. de; XAVIER, MARCOS; SILVA, NATALIA F.; CALDAS, LINDA V.E.
    A tomografia computadorizada (CT) vem crescendo devido aos avanços da tecnologia dos equipamentos, proporcionando uma dose maior no paciente, em relação aos demais exames de radiodiagnóstico, levando a uma preocupação com os pacientes. A dosimetria em CT é realizada com uma câmara de ionização do tipo lápis com comprimento de volume sensível de 10 cm. Os estudos têm mostrado a subestimação dos valores de dose. Foram desenvolvidas neste trabalho duas câmaras de ionização com comprimentos de volume sensível de 30 cm, que foram submetidas aos testes principais de caracterização, obtendo-se resultados dentro dos limites recomendáveis internacionalmente.
  • Artigo IPEN-doc 20431
    Avaliação de uma nova câmara de ionização tipo lápis para dosimetria em feixes de tomografia computadorizada
    2014 - CASTRO, MAYSA C. de; NEVES, LUCIO P.; SILVA, NATALIA F. da; SANTOS, WILLIAN de S.; CALDAS, LINDA V.E.