  • Artigo IPEN-doc 28153
    Performance comparison of an extrapolation chamber in computed tomography standard beams of two laboratories
    2021 - CASTRO, MAYSA C.; SILVA, NATALIA F.; SANTOS, WILLIAM S.; CALDAS, LINDA V.E.
    The doses received by the patients during the computed tomography (CT) exams are the highest when compared to other diagnostic radiology procedures. This fact makes it so important to keep the quality control using the correct instrument. For dosimetry in CT, a pencil type ionization chamber is usually utilized with a sensitive volume length of 10 cm. A comparison of the performance of an extrapolation chamber in two different laboratories, at the Instrument Calibration Laboratory (LCI) from Instituto de Pesquisas Energéticas e Nucleares (IPEN, Brazil) and at the National Physical Laboratory (NPL, UK) was undertaken. Two chamber characteristics were determined (zero depth and extrapolation curve), and the main recommended characterization tests were performed (stabilization time, saturation curve, polarity effect, ion collection efficiency, linearity of response, and variation of response with source-detector distance). This extrapolation chamber was calibrated using the standard system of NPL laboratory, and the energy dependence was determined. The results obtained were within the international recommendations of IEC 61674, except for the energy dependence, as already expected. This study also established a reference system for the LCI of the IPEN, using a homemade extrapolation chamber for X-ray CT beams. Using the extrapolation curves obtained in the characterization tests and the correction factors of ionic recombination, and scattering and fluorescence, the air kerma rates were obtained, as a reference system in standard laboratory computed tomography beams. The last correction factor was obtained using computer simulations by the MCNP5 code (Monte Carlo). Moreover, two pencil type ionization chambers were calibrated using the replacement method in relation to the extrapolation chamber.
  • Artigo IPEN-doc 27209
    Evaluation of an extrapolation chamber for dosimetry in computed tomography beams using Monte Carlo code (MCNP5)
    2020 - CASTRO, MAYSA C.; SILVA, NATALIA F.; SANTOS, LUCAS R.; CINTRA, FELIPE B.; CALDAS, LINDA V.E.
    Computed tomography (CT) is responsible for the highest dose values to the patients during the exams. Therefore, the radiation doses in this procedure must be accurate. However, there is no primary standard system for this kind of radiation beam yet. A homemade extrapolation ionization chamber was preliminary evaluated for the establishment of a CT beam primary standard. The aim of this study was to determine the influence that the various components of the extrapolation chamber may present on the energy deposited in its sensitive volume. Different materials for its collecting electrode were also studied for this type of radiation beam. The evaluation of the homemade extrapolation chamber showed the highest influence of 25.9% for the collecting electrode, and the best material for the collecting electrode for CT radiation beams was graphite.