  • Artigo IPEN-doc 28153
    Performance comparison of an extrapolation chamber in computed tomography standard beams of two laboratories
    2021 - CASTRO, MAYSA C.; SILVA, NATALIA F.; SANTOS, WILLIAM S.; CALDAS, LINDA V.E.
    The doses received by the patients during the computed tomography (CT) exams are the highest when compared to other diagnostic radiology procedures. This fact makes it so important to keep the quality control using the correct instrument. For dosimetry in CT, a pencil type ionization chamber is usually utilized with a sensitive volume length of 10 cm. A comparison of the performance of an extrapolation chamber in two different laboratories, at the Instrument Calibration Laboratory (LCI) from Instituto de Pesquisas Energéticas e Nucleares (IPEN, Brazil) and at the National Physical Laboratory (NPL, UK) was undertaken. Two chamber characteristics were determined (zero depth and extrapolation curve), and the main recommended characterization tests were performed (stabilization time, saturation curve, polarity effect, ion collection efficiency, linearity of response, and variation of response with source-detector distance). This extrapolation chamber was calibrated using the standard system of NPL laboratory, and the energy dependence was determined. The results obtained were within the international recommendations of IEC 61674, except for the energy dependence, as already expected. This study also established a reference system for the LCI of the IPEN, using a homemade extrapolation chamber for X-ray CT beams. Using the extrapolation curves obtained in the characterization tests and the correction factors of ionic recombination, and scattering and fluorescence, the air kerma rates were obtained, as a reference system in standard laboratory computed tomography beams. The last correction factor was obtained using computer simulations by the MCNP5 code (Monte Carlo). Moreover, two pencil type ionization chambers were calibrated using the replacement method in relation to the extrapolation chamber.
  • Artigo IPEN-doc 27209
    Evaluation of an extrapolation chamber for dosimetry in computed tomography beams using Monte Carlo code (MCNP5)
    2020 - CASTRO, MAYSA C.; SILVA, NATALIA F.; SANTOS, LUCAS R.; CINTRA, FELIPE B.; CALDAS, LINDA V.E.
    Computed tomography (CT) is responsible for the highest dose values to the patients during the exams. Therefore, the radiation doses in this procedure must be accurate. However, there is no primary standard system for this kind of radiation beam yet. A homemade extrapolation ionization chamber was preliminary evaluated for the establishment of a CT beam primary standard. The aim of this study was to determine the influence that the various components of the extrapolation chamber may present on the energy deposited in its sensitive volume. Different materials for its collecting electrode were also studied for this type of radiation beam. The evaluation of the homemade extrapolation chamber showed the highest influence of 25.9% for the collecting electrode, and the best material for the collecting electrode for CT radiation beams was graphite.
  • Resumo IPEN-doc 26066
  • Artigo IPEN-doc 24239
    Comparação entre duas câmaras de ionização do tipo lápis com comprimento de volume sensível de 30 cm
    2017 - CASTRO, M.C.; XAVIER, M.; SILVA, N.F.; CALDAS, L.V.E.
    A tomografia computadorizada (CT) vem crescendo devido aos avanços da tecnologia dos equipamentos, proporci-onando uma dose maior no paciente, em relação aos demais exames de radiodiagnóstico, levando a uma preocupa-ção com os pacientes. A dosimetria em CT é realizada com uma câmara de ionização do tipo lápis com comprimen-to de volume sensível de 10 cm. Os estudos têm mostrado a subestimação dos valores de dose. Foram desenvolvidas neste trabalho duas câmaras de ionização com comprimentos de volume sensível de 30 cm, que foram submetidas aos testes principais de caracterização, obtendo-se resultados dentro dos limites recomendáveis internacionalmente. Palavras-chave: Dosimetria, tomografia computadorizada, câmara de ionização especial.
  • Artigo IPEN-doc 24229
    Development and tests of a 30cmpencil-type ionization chamber for dosimetry in standard and clinical CT beams
    2017 - CASTRO, M.C.; SILVA, N.F.; XAVIER, M.; ANDRADE, M.E.A.; KHOURY, H.J.; CALDAS, L.V.E.
    The use of computed tomography (CT) for imaging procedures is growing due to advances in the CT equipment technology. To perform the dosimetry inCT beams, the most widely used instrument is the pencil type ionization chamber with a sensitive volume length of 100 mm; however, some studies have shown that this dosimeter has underestimated the dose values. Therefore, in this study an ionization chamber with sensitive volume length of 300mmwas developed at IPEN. The characterization of this chamber was performed, and the results were obtained within the international recommended limits. As an application, the developed ionization chamber was tested in clinical beams of two different hospitals.
  • Artigo IPEN-doc 23115
    Characterization of a free air ionization chamber for low energy X-rays
    2016 - SILVA, NATALIA F. DA; XAVIER, M.; VIVOLO, V.; CALDAS, L.V.E.
    Free air ionization chambers are used by most primary metrology laboratories as primary standards of the quantities air kerma and exposure in X-ray beams. The free air ionization chamber for low energies of the Calibration Laboratory (LCI) of IPEN showed in a characterization test a problem in the set responsible for the variation of its sensitive volume. After a modification in the support of the micrometers used for the movement of the internal cylinder and the establishment of a new alignment system protocol, the tests were redone. The objective of this work was to present the results obtained in the new condition.
  • Artigo IPEN-doc 22873
    Comparação entre duas câmaras de ionização do tipo lápis com comprimento de volume sensível de 30 cm
    2016 - CASTRO, MAYSA C. de; XAVIER, MARCOS; SILVA, NATALIA F.; CALDAS, LINDA V.E.
    A tomografia computadorizada (CT) vem crescendo devido aos avanços da tecnologia dos equipamentos, proporcionando uma dose maior no paciente, em relação aos demais exames de radiodiagnóstico, levando a uma preocupação com os pacientes. A dosimetria em CT é realizada com uma câmara de ionização do tipo lápis com comprimento de volume sensível de 10 cm. Os estudos têm mostrado a subestimação dos valores de dose. Foram desenvolvidas neste trabalho duas câmaras de ionização com comprimentos de volume sensível de 30 cm, que foram submetidas aos testes principais de caracterização, obtendo-se resultados dentro dos limites recomendáveis internacionalmente.
  • Artigo IPEN-doc 22684
    Determinação do fator de correção para atenuação no ar para uma câmara de ionização de ar livre
    2016 - SILVA, NATALIA F.; CINTRA, FELIPE B.; CASTRO, MAYSA C. de; CALDAS, LINDA V.E.
    Este trabalho tem como objetivo apresentar os resultados obtidos experimentalmente e por simulação para o fator de correção da atenuação no ar de uma câmara de ionização de ar livre de cilindros concêntricos Victoreen, modelo 481- 5. Este fator de correção foi obtido para as qualidades padronizadas de mamografia, estabelecidas no Laboratório de Calibração de Instrumentos (LCI) do IPEN. Os valores obtidos foram comparados com os resultados do laboratório padrão primário alemão Physikalisch-Technische Bundesanstalt (PTB), obtendo-se diferenças máximas de 0,40% para o valor experimental e de 0,31% para o valor simulado.
  • Dissertação IPEN-doc 21778
    Estabelecimento de um sistema padrão primário para raios X de energias baixas com uma câmara de ionização de ar livre
    2016 - SILVA, NATALIA F. da
    Neste trabalho foi estabelecido um sistema padrão primário para raios X de energias baixas (10 kV a 50 kV), utilizando uma câmara de ionização de ar livre de cilindros concêntricos da marca Victoreen (modelo 481-5) no Laboratório de Calibração de Instrumentos (LCI) do Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP). Para isso foi desenvolvido um novo protocolo de alinhamento da câmara de ionização no sistema de radiação e foi feita uma modificação no suporte dos micrômetros utilizados para o movimento dos cilindros internos. Os resultados obtidos nos testes de estabilidade e de caracterização ficaram dentro dos limites estabelecidos pelas normas IEC 61674 e IEC 60731. Foram determinados também os fatores de correção para atenuação de fótons no ar, transmissão e espalhamento no diafragma, espalhamento e fluorescência, e recombinação iônica. Esses valores foram comparados com os valores obtidos pelo laboratório padrão primário alemão,Physikalisch-Technische Bundesanstalt (PTB), mostrando boa concordância. Por último, foi determinado o valor absoluto da grandeza taxa de kerma no ar para as qualidades padronizadas de mamografia de feixes diretos WMV28 e WMV35 e feixes atenuados WMH28 e WMH35; os resultados são compatíveis, com diferença máxima de 3,8% com os valores obtidos utilizando o sistema padrão secundário do LCI.
  • Artigo IPEN-doc 21410
    Caracterização de uma camara de ionização de ar livre para baixas energias
    2015 - SILVA, NATALIA F.; XAVIER, MARCOS; VIVOLO, VITOR; CALDAS, LINDA V.E.