JOAO VICTOR DE SOUSA ARAUJO

Projetos de Pesquisa
Unidades Organizacionais
Cargo

Resultados de Busca

Agora exibindo 1 - 10 de 12
  • Artigo IPEN-doc 29682
    Investigação da atividade eletroquímica de liga Al-Cu-Li após processo de soldagem por fricção e mistura
    2023 - SILVA, REJANE M.P. da; MILAGRE, MARIANA X.; ARAUJO, JOAO V. de S.; RAMIREZ, OSCAR M.P.; MACHADO, CARULINE de S.C.; ANTUNES, RENATO A.; COSTA, ISOLDA
    In this work, the local electrochemical activity of the zones coupled by Friction Stir Welding (FSW) of an Al-Cu-Li alloy was studied and the results were correlated to the microstructural characteristics of each zone. Electrochemical studies were carried out in the zones affected by welding using cyclic voltammetry (CV) and scanning electrochemical techniques (namely, SECM - Scanning Electrochemical Microscopy and LEIS – Local electrochemical impedance spectroscopy). The results showed that the welding joint (WJ) is predominantly cathodic relatively to the heat affected zones (HAZ). The HAZ was always anodic and showed the highest electrochemical activities among the tested ones. The high electrochemical activity of the HAZ was associated with the effect of galvanic coupling between the cathodic region (WJ) and the anodic region (HAZ). In addition, the advancing side (AS) presented increased electrochemical activity compared to the retreating one (RS).
  • Artigo IPEN-doc 29075
    Surface finishing effects on the corrosion behavior and electrochemical activity of 2098-T351 aluminum alloy investigated using scanning microelectrochemical techniques
    2022 - SILVA, REJANE M.P. da; MILAGRE, MARIANA X.; IZQUIERDO, JAVIER; BETANCOR-ABREU, ABENCHARA M.; OLIVEIRA, LEANDRO A. de; ARAUJO, JOAO V. de S.; ANTUNES, RENATO A.; SOUTO, RICARDO M.; COSTA, ISOLDA
    The effects of surface finishing on the corrosion behavior and electrochemical activity of AA2098-T351 (Al–Cu–Li alloy) were investigated on the basis of the correlation between surface chemistry, microstructure and electrochemical activity. The alloy was evaluated in the as-received and polished conditions. The morphology of the two types of surfaces was investigated using confocal laser scanning microscopy (CLSM), optical microscopy and optical 3D profilometry. The surface chemistry was analyzed by X-ray photoelectron spectroscopy (XPS) and energy dispersive X-ray spectroscopy (EDX). Scanning microelectrochemical techniques (namely, localized electrochemical impedance spectroscopy (LEIS), the scanning vibrating electrode technique (SVET) and scanning electrochemical microscopy (SECM) in potentiometric mode) were used to examine the electrochemical activity of the surfaces. The results showed that on the as-received surface, the near surface deformed layer (NSDL), which is composed of Mg-rich bands, influenced the corrosion activity of the alloy. Higher electrochemical activity and greater susceptibility to severe localized corrosion were related to the polished surface condition compared to the as-received one.
  • Artigo IPEN-doc 29046
    Electrochemical characterization of alloy segregation in the near-surface deformed layer of welded zones of an Al-Cu-Li alloy using scanning electrochemical microscopy
    2022 - SILVA, REJANE M.P. da; IZQUIERDO, JAVIER; MILAGRE, MARIANA X.; ARAUJO, JOAO V. de S.; ANTUNES, RENATO A.; SOUTO, RICARDO M.; COSTA, ISOLDA
    The development of heterogeneous electrochemical activity in the welded zones of aluminum alloy 2098-T351 by friction stir welding (FSW) associated with the formation of a near-surface deformed layer (NSDL) upon exposure to an aqueous chloride-containing solution was characterized using scanning electrochemical microscopy (SECM) in potentiometric operation. A solid-contact Mg2+ ion-selective microelectrode allowed in situ monitoring of the corrosion reactions sites for magnesium dissolution from different zones of the FSW weld upon exposure to a chloride-containing aqueous environment. In this way, localized corrosion reactions developing in the galvanically coupled joint/heat affected zones (WJ/HAZ) of the weld were detected and imaged with spatial resolution. The most active domains for local Mg2+ concentrations were associated with the HAZ of the retreating side (RS), and these corresponded to Mg oxidation from the Mg-enriched oxide bands in NSDL.
  • Artigo IPEN-doc 28933
    Corrosion behaviour of the 2098-T351 Al–Cu–Li alloy after different surface treatments
    2022 - BARBOZA, WANESSA das G.; MILAGRE, MARIANA X.; DONATUS, UYIME; MACHADO, CARULINE de S.C.; RAMIREZ, OSCAR M.P.; ARAUJO, JOAO V. de S.; SILVA, REJANE M.P. da; COSTA, ISOLDA
    The effect of different surface treatments on the corrosion resistance of the AA2098 Al–Cu–Li alloy has been investigated. Surface characterization was performed using 3D optical profilometry, energy dispersive X-ray spectroscopy and scanning electron microscopy. The corrosion resistance of the 2098 alloy after the surface treatments was investigated in 0.1 mol L−1 NaCl solution by electrochemical techniques and microscopy. Corrosion results showed that the untreated and the chemically etched surfaces were more active than the mechanically abraded and mechanically polished surfaces owing to differences in the nature of the native oxides formed after the surface treatments. Corrosion rate and mode were also affected by how close the exposed surface was to the mid-thickness region of the AA2098-T351 plate relative to the actual top surface (before polishing). This is associated with the variation in the volume fraction and distribution of the T1 phase as the mid-thickness region of the AA2098-T351 plate is approached.
  • Artigo IPEN-doc 28531
    Influence of chloride ions concentration on the development of severe localised corrosion and its effects on the electrochemical response of the 2198-T8 alloy
    2021 - MACHADO, CARULINE de S.C.; SILVA, REJANE M.P. da; ARAUJO, JOAO V. de S.; MILAGRE, MARIANA X.; DONATUS, UYIME; VIVEIROS, BARBARA V.G. de; KLUMPP, RAFAEL E.; COSTA, ISOLDA
    The development of severe localised corrosion (SLC) on the 2198-T8 alloy was investigated in solutions of various NaCl concentrations (0.001, 0.005 and 0.01 mol L−1). Immersion tests, optical profilometry, conventional and local electrochemical analyses were performed to evaluate the corrosion behaviour of the alloy. Immersion tests showed that the alloy is susceptible to SLC in all conditions, although the pits sizes were dependent on the solution concentration. The largest anodic areas, corresponding to SLC sites, were observed for the sample immersed in 0.001 mol L−1 NaCl, whereas pits with similar sizes were observed for the samples immersed in solutions with 0.005 and 0.01 mol L−1 of NaCl. Moreover, the maximum depth of attack was observed for the sample immersed in 0.001 mol L−1 NaCl. These results were in agreement with the scanning ionselective electrode technique (SIET) maps which showed stronger acidification on the sample exposed to 0.001 mol L−1 NaCl solution.
  • Artigo IPEN-doc 27712
    Corrosion protection of the AA2198-T8 alloy by environmentally friendly organic-inorganic sol-gel coating based on bis-1,2-(triethoxysilyl) ethane
    2021 - KLUMPP, RAFAEL E.; DONATUS, UYIME; SILVA, REJANE M.P. da; ANTUNES, RENATO A.; MACHADO, CARULINE de S.C.; MILAGRE, MARIANA X.; ARAUJO, JOAO V. de S.; VIVEIROS, BARBARA V.G. de; COSTA, ISOLDA
    In this work, a surface coating composed of organic‐inorganic hybrid sol‐gel based on bis‐1,2‐(triethoxysilyl) (BTSE) ethane was applied on AA2198‐T8 samples, and its effect on corrosion resistance was investigated and compared with that of a chromate layer formed in a solution with hexavalent chromium ions. The corrosion resistance of BTSE coated samples was evaluated by immersion tests in sodium chloride solution (0.005 mol/L NaCl) and monitored by global electrochemical techniques such as electrochemical impedance spectroscopy (EIS) and local electrochemical techniques such as scanning vibrating electrode technique (SVET) and scanning electrochemical microscopy (SECM). The formed coating layers were characterized by X‐ray photoelectron spectroscopy (XPS). The results pointed out that the BTSE is an effective alternative coating for corrosion protection of new generation Al‐Cu‐Li alloys and could replace chromates obtained in toxic and carcinogenic CrVI containing solutions leading to improved corrosion protection.
  • Artigo IPEN-doc 27686
    Mecanismo de evolução de hidrogênio durante a corrosão da liga 2198-T8 em meio contendo cloreto
    2020 - ARAUJO, JOAO V. de S.; SILVA, REJANE M.P. da; MILAGRE, MARIANA X.; MACHADO, CARULINE de S.C.; COSTA, ISOLDA
    Corrosion is still one of the most serious and frequent problems in industries. The phenomena involved in the corrosion mechanism of Al-alloys may be explained by formation of galvanic cells between the metal matrix and heterogeneities, such as precipitates, intermetallic phases leading to potential differences and electrochemical reactions. In the cathodic sites, the main reactions are oxygen reduction reaction, in aerated neutral environments, and hydrogen evolution in acid media. This last type of reaction might also occur in neutral solutions inside pits (anodic region). In this study, the mechanism of hydrogen evolution during corrosion of the 2198-T8 Al-Cu-Li alloy exposed in a chloride solution was investigated. The mechanism was related to the presence of T1 phase (Al2CuLi), which is the main strengthening phase in this material. This phase is highly active and, when exposed to corrosive media, leads to severe localized corrosion (SLC). One of the main characteristics related to SLC is hydrogen gas evolution which was confirmed by gel visualization. In this study, the hydrogen evolution mechanism inside the SLC sites was studied by scanning electrochemical microscopy (SECM).
  • Artigo IPEN-doc 27402
    Microstructural, electrochemical and localized corrosion characterization of the AA2198-T851 alloy
    2020 - ARAUJO, JOAO V. de S.; SILVA, REJANE M.P. da; DONATUS, UYIME; MACHADO, CARULINE de S.C.; COSTA, ISOLDA
    In the present work, the microstructure, electrochemical behavior and localized corrosion of the AA2198-T851 Al-Cu-Li alloy were studied. The microstructure was correlated with corrosion results obtained by immersion, gel visualization and scanning electrochemical microscopy (SECM) tests. Immersion and gel visualization tests showed high kinetics of corrosion attack during the first hours of immersion. SECM analyzes by means of surface generation/tip collection (SG/TC) mode detected hydrogen evolution generated during spontaneous corrosion from severe localized corrosion (SLC) sites on the metal surface. SECM results revealed sites of intense hydrogen evolution after 2 h of immersion and increased amounts of corrosion products after 4 h of immersion. Hydrogen evolution sites detected by SECM were associated with severe localized corrosion (SLC).
  • Artigo IPEN-doc 27391
    Galvanic coupling effects on the corrosion behavior of the 6061 aluminum alloy used in research nuclear reactors
    2020 - MILAGRE, MARIANA X.; DONATUS, UYIME; SILVA, REJANE M.P.; BETANCOR-ABREU, ABENCHARA M.; RAMIREZ, OSCAR M.P.; MACHADO, CARULINE S.C.; ARAUJO, JOAO V.S.; SOUTO, RICARDO M.; COSTA, ISOLDA
    The 6061 alloy is used in different thermomechanical conditions in research nuclear reactors. Nuclear fuel plates are manufactured by the picture frame technique (PFT) and the 6061 alloy is used as cladding for the nuclear fuel “sandwiches”. After the PFT process, these nuclear plates are placed in a case made of 6061-T6 alloy. In this work, the galvanic effects of coupling the 6061 alloy in the T6 and PFT temper conditions were investigated in different chloride-containing solutions. The results showed that galvanic coupling was favored between the PFT and 6061-T6 alloy. A potential difference of about 50 mV was observed between the temper conditions. This was attributed to differences in β’’ phase density between the two conditions (T6 and PFT) which was indicated by microhardness results. The 6061 alloy in the PFT condition was cathodic in relation to the T6 one. Results from conventional electrochemical techniques were in agreement with the local measurements. Local electrochemical techniques such as the SVET, SECM and LEIS were useful in characterizing the electrochemical behavior of the galvanically coupled alloys.
  • Artigo IPEN-doc 26823
    Effects of chloride ion concentration on the corrosion behavior of the AA2198-T8 alloy
    2019 - MACHADO, CARULINE de S.C.; SILVA, REJANE M. da; ARAUJO, JOAO V. de S.; DONATUS, UYIME; MILAGRE, MARIANA X.; KLUMPP, RAFAEL E.; ROSSI, JESUALDO L.; COSTA, ISOLDA
    In this work, the influence of chloride ions concentration on the corrosion behavior of the AA2198-T8 alloy was evaluated. Immersion test and electrochemical analyses were performed in sodium chloride solutions of three concentrations, 0.001 mol L-1, 0.005 mol L-1 and 0.01 mol L-1. The results showed that the AA2198-T8 alloy was susceptible to localized corrosion (LC) and to severe localized corrosion (SLC) in all conditions investigated. The electrochemical results obtained by open circuit potential measurements, cyclic voltammetry and potentiodynamic polarization curves were associated with the corroded microstructure of the alloy. Although electrochemical techniques allowed differentiating the corrosion resistance as a function of chloride concentration, the result was strongly influenced by the corroded/uncorroded area ratio related to the SLC.