JOAO VICTOR DE SOUSA ARAUJO

Projetos de Pesquisa
Unidades Organizacionais
Cargo

Resultados de Busca

Agora exibindo 1 - 9 de 9
  • Artigo IPEN-doc 28531
    Influence of chloride ions concentration on the development of severe localised corrosion and its effects on the electrochemical response of the 2198-T8 alloy
    2021 - MACHADO, CARULINE de S.C.; SILVA, REJANE M.P. da; ARAUJO, JOAO V. de S.; MILAGRE, MARIANA X.; DONATUS, UYIME; VIVEIROS, BARBARA V.G. de; KLUMPP, RAFAEL E.; COSTA, ISOLDA
    The development of severe localised corrosion (SLC) on the 2198-T8 alloy was investigated in solutions of various NaCl concentrations (0.001, 0.005 and 0.01 mol L−1). Immersion tests, optical profilometry, conventional and local electrochemical analyses were performed to evaluate the corrosion behaviour of the alloy. Immersion tests showed that the alloy is susceptible to SLC in all conditions, although the pits sizes were dependent on the solution concentration. The largest anodic areas, corresponding to SLC sites, were observed for the sample immersed in 0.001 mol L−1 NaCl, whereas pits with similar sizes were observed for the samples immersed in solutions with 0.005 and 0.01 mol L−1 of NaCl. Moreover, the maximum depth of attack was observed for the sample immersed in 0.001 mol L−1 NaCl. These results were in agreement with the scanning ionselective electrode technique (SIET) maps which showed stronger acidification on the sample exposed to 0.001 mol L−1 NaCl solution.
  • Artigo IPEN-doc 27430
    Exfoliation and intergranular corrosion resistance of the 2198 Al–Cu–Li alloy with different thermomechanical treatments
    2020 - ARAUJO, JOAO V. de S.; MILAGRE, MARIANA X.; FERREIRA, RAPHAEL O.; MACHADO, CARULINE de S.C.; BUGARIN, ALINE de F.S.; MACHADO, IZABEL F.; COSTA, ISOLDA
    In this study, the resistance to exfoliation and intergranular corrosion (IGC) of the 2198 Al–Cu–Li alloy submitted to different thermomechanical treatments (T3, T8, and T851) was investigated. The tests were carried out following the standard practices, ASTM G34‐18 and ASTM G110‐15, respectively. All the tested alloys showed susceptibility to exfoliation and some alloys showed susceptibility to IGC, but the artificially aged alloys presented a higher tendency to exfoliation. The extensive hydrogen evolution reaction (HER) was observed on the surfaces of artificially aged alloys when immersed in the EXCO solution. The HER resulted in an increase in solution pH with the time of immersion. Also, the weight losses related to the artificially aged alloys were higher than that of the naturally aged ones. The T8 treatment was the only condition that resulted in susceptibility to both, intergranular and transgranular corrosion, whereas the T851 treatment did not show IGC susceptibility, only transgranular corrosion. Finally, the 2198‐T3 condition showed the highest corrosion resistance among the thermomechanical treatments tested. The results of the 2198 alloy subjected to various treatments were compared with that of the 2024‐T3 alloy. This last alloy showed higher resistance to exfoliation and IGC as compared with the 2198 alloy.
  • Artigo IPEN-doc 27391
    Galvanic coupling effects on the corrosion behavior of the 6061 aluminum alloy used in research nuclear reactors
    2020 - MILAGRE, MARIANA X.; DONATUS, UYIME; SILVA, REJANE M.P.; BETANCOR-ABREU, ABENCHARA M.; RAMIREZ, OSCAR M.P.; MACHADO, CARULINE S.C.; ARAUJO, JOAO V.S.; SOUTO, RICARDO M.; COSTA, ISOLDA
    The 6061 alloy is used in different thermomechanical conditions in research nuclear reactors. Nuclear fuel plates are manufactured by the picture frame technique (PFT) and the 6061 alloy is used as cladding for the nuclear fuel “sandwiches”. After the PFT process, these nuclear plates are placed in a case made of 6061-T6 alloy. In this work, the galvanic effects of coupling the 6061 alloy in the T6 and PFT temper conditions were investigated in different chloride-containing solutions. The results showed that galvanic coupling was favored between the PFT and 6061-T6 alloy. A potential difference of about 50 mV was observed between the temper conditions. This was attributed to differences in β’’ phase density between the two conditions (T6 and PFT) which was indicated by microhardness results. The 6061 alloy in the PFT condition was cathodic in relation to the T6 one. Results from conventional electrochemical techniques were in agreement with the local measurements. Local electrochemical techniques such as the SVET, SECM and LEIS were useful in characterizing the electrochemical behavior of the galvanically coupled alloys.
  • Artigo IPEN-doc 27178
    Galvanic and asymmetry effects on the local electrochemical behavior of the 2098-T351 alloy welded by friction stir welding
    2020 - MILAGRE, MARIANA X.; DONATUS, UYIME; MOGILI, NAGA V.; SILVA, REJANE M.P.; VIVEIROS, BARBARA V.G. de; PEREIRA, VICTOR F.; ANTUNES, RENATO A.; MACHADO, CARULINE S.C.; ARAUJO, JOAO V.S.; COSTA, ISOLDA
    Scanning electrochemical microscopy (SECM) and scanning vibrating electrode technique (SVET) were used to investigate the electrochemical behaviour of the top surface of the 2098-T351 alloy welded by friction stir welding (FSW). The SVET technique was efficient in identifying the cathodic and anodic weld regions. The welding joint (WJ), which comprises the thermomechanically affected zone (TMAZ) and the stir zone (SZ), was cathodic relative to the heated affected zone (HAZ) and the base metal (BM). The reactivities of the welding joint at the advancing side (AS) and the retreating side (RS) were analyzed and compared using SECM technique in the competition mode by monitoring the dissolved oxygen as a redox mediator in 0.005 mol L−1 NaCl solution. The RS was more electrochemically active than the AS, and these results were correlated with the microstructural features of the welded alloy.
  • Artigo IPEN-doc 26823
    Effects of chloride ion concentration on the corrosion behavior of the AA2198-T8 alloy
    2019 - MACHADO, CARULINE de S.C.; SILVA, REJANE M. da; ARAUJO, JOAO V. de S.; DONATUS, UYIME; MILAGRE, MARIANA X.; KLUMPP, RAFAEL E.; ROSSI, JESUALDO L.; COSTA, ISOLDA
    In this work, the influence of chloride ions concentration on the corrosion behavior of the AA2198-T8 alloy was evaluated. Immersion test and electrochemical analyses were performed in sodium chloride solutions of three concentrations, 0.001 mol L-1, 0.005 mol L-1 and 0.01 mol L-1. The results showed that the AA2198-T8 alloy was susceptible to localized corrosion (LC) and to severe localized corrosion (SLC) in all conditions investigated. The electrochemical results obtained by open circuit potential measurements, cyclic voltammetry and potentiodynamic polarization curves were associated with the corroded microstructure of the alloy. Although electrochemical techniques allowed differentiating the corrosion resistance as a function of chloride concentration, the result was strongly influenced by the corroded/uncorroded area ratio related to the SLC.
  • Artigo IPEN-doc 26650
    Correlating the modes of corrosion with microstructure in the friction stir welded AA2198-T8 alloy in aqueous hydrogen peroxide-chloride medium
    2019 - MACHADO, CARULINE de S.C.; DONATUS, UYIME; MILAGRE, MARIANA X.; MOGILI, NAGA V.V.; GIORJÃO, RAFAEL A.R.; KLUMPP, RAFAEL E.; ARAUJO, JOAO V. de S.; FERREIRA, RAPHAEL O.; COSTA, ISOLDA
    In this study, different types of localized corrosion in the friction stir welding (FSW) zones of an AA2198-T8 when the alloy is subjected to a corrosion test in a hydrogen peroxide–chloride solution (according to ASTM G110 standard) has been investigated. The corrosion modes were correlated with microstructure, especially with respect to the T1 phase and coarse Al-Cu-Fe phase distribution across the weldment. Simulated thermal profile and microhardness measurements were used to establish the variations in T1 phase distribution. Two types of corrosion were observed in the FSW zones: intense pitting and intergranular corrosion—type I; and the formation of cavities and trenches—type II. Type I is associated with the T1 phase while type II is associated with Al-Cu-Fe coarse intermetallics. Both types were found on the base metal (BM) and heat affected zone, but the type I reduced in the latter toward the stir zone (SZ). The SZ/thermomechanically affected zone (TMAZ) exhibited only type II. Also, Cu enrichment was observed around the type II sites in the SZ/TMAZ. Furthermore, an inverse correlation between microhardness and corrosion resistance which was related to T1 phase concentration in the different zones was also observed. Moreover, the SZ and BM were isolated and evaluated by an immersion test and electrochemical analysis using the ASTM G110 test solution. The results indicated galvanic coupling effects, as the SZ was strongly attacked when exposed separately compared to when it was coupled with the other zones.
  • Artigo IPEN-doc 26643
    Exfoliation corrosion susceptibility in the zones of friction stir welded AA2098-T351
    2019 - MILAGRE, MARIANA X.; DONATUS, UYIME; MACHADO, CARULINE S.C.; ARAUJO, JOAO V.S.; FERREIRA, RAPHAEL O.; SILVA, REJANE M.P.; ANTUNES, RENATO A.; COSTA, ISOLDA
    In the present study, the exfoliation susceptibility of the weld zones in friction stir weldedAA2098-T351 was compared with that of the base metal (BM) according to ASTM G34 stan-dard practice. Friction stir welding (FSW) had a significant effect on the microstructure of theAl alloy tested and the susceptibility to exfoliation was strongly affected by the microstruc-ture. Different features of corrosion attack and exfoliation susceptibility were observed whenthe zones affected by FSW were tested isolated or coupled. Also, the near-surface deformedlayer had an important effect on the Al alloy susceptibility to exfoliation. These are themain findings of this work. The corrosion features were correlated with the microstructuralmodifications related to the welding process and with the electrochemical response. TheT1 phase morphology, distribution and size were critical for exfoliation susceptibility. Thestir zone (SZ) was the zone most resistant to exfoliation. However, resistance to exfoliationvaried with the temperatures reached in the heat affected zones (HAZs). The HAZ exposedto the lowest temperatures during welding, HAZ (LT), was the most susceptible to exfoli-ation, whereas the HAZ exposed to the highest temperatures, HAZ (HT), presented highresistance to exfoliation, similarly to the SZ. The ASTM-G34 practice was an effective anduseful method in identifying the different exfoliation resistances of the BM and the vari-ous zones affected by FSW. The results of this practice were supported by electrochemicalimpedance spectroscopy (EIS) tests.
  • Artigo IPEN-doc 25861
    Effect of surface treatments on the localized corrosion resistance of the AA2198‐T8 aluminum lithium alloy welded by FSW process
    2019 - MACHADO, CARULINE de S.C.; KLUMPP, RAFAEL E.; AYUSSO, VICTOR H.; DONATUS, UYIME; MILAGRE, MARIANA X.; ARAUJO, JOAO V. de S.; MACHADO, GLAUSON A.F.; COSTA, ISOLDA
    In this work, the effect of eight types of surface treatments on the corrosion resistance of friction stir welded samples of an AA2198‐T8 Al‐Cu‐Li alloy were tested and compared in an attempt to find suitable alternatives to toxic and carcinogenic hexavalent chromium treatments. All the samples were anodized and subjected to different post‐anodizing treatments. The post‐anodizing treatments were (1) hydrothermal treatment in Ce (NO3)3 6H2O solution; (2) hydrothermal treatment in Ce (NO3)3 6H2O solution with H2O2; (3) hydrothermal treatment in boiling water; (4) hexavalent chromium conversion coating; and (5) immersion in BTSE (bis‐1,2‐(triethoxysilyl) ethane. The corrosion resistance of the treated samples was evaluated by immersion tests in sodium chloride solution (0.1 mol L−1 NaCl) and electrochemical impedance spectroscopy (EIS) of the friction stir weldment. The results showed that among the alternative treatments, the Ce‐containing solutions presented the best corrosion resistance, especially when used without peroxide.
  • Artigo IPEN-doc 24705
    On the severe localized corrosion susceptibility of the AA2198-T851 alloy
    2018 - ARAUJO, JOAO V. de S.; DONATUS, UYIME; QUEIROZ, FERNANDA M.; TERADA, MAYSA; MILAGRE, MARIANA X.; ALENCAR, MAICON C. de; COSTA, ISOLDA
    The time dependent susceptibility of AA2198-T851 Al-Cu-Li alloy to severe localized corrosion in 0.01 mol L-1 NaCl solution has been investigated by immersion and SVET tests. The results reveal that the propagation of severe localized corrosion, in the alloy, is crystallographic and it is associated with the slip bands in the individual grains of the alloy. The slip bands caused uneven precipitation of the active T1 particles. Also, oscillations in SVET current density values associated with deposition and detachment of corrosion products were observed. Furthermore, the intensity of corrosion activities increased over time for open or partially covered pits.