  • Artigo IPEN-doc 26468
    Mass energy absorption coefficients and energy responses of magnesium tetraborate dosimeters for 0.02 MeV to 20 MeV photons using Monte Carlo simulations
    2019 - SOUZA, LUIZA F.; SANTOS, WILLIAM S.; BELINATO, WALMIR; SILVA, ROGERIO M.V.; CALDAS, LINDA V.E.; SOUZA, DIVANIZIA N.
    Thermoluminescence dosimeters containing boron, such as magnesium tetraborate (MgB4O7), are of interest because of their very high sensitivity, near tissue-equivalent absorption coefficients, low cost, easy handling, and very large linearity range for absorbed dose. Another important parameter that should be considered when working with thermoluminescent dosimeter (TLD) is the mass energy absorption coefficient (μen/ρ), which is a close approximation to the energy available for production of chemical, biological and other effects associated with exposure to ionizing radiation, therefore important in estimating dose in medical and health physics. In this study the mass energy absorption coefficients and energy responses of undoped and some doped magnesium tetraborates were calculated by Monte Carlo N-particle transport code for a range of photon energies between 20 keV and 20 MeV. The calculated parameters for MgB4O7, MgB4O7:Dy and MgB4O7:Dy,Li were evaluated in comparison with standard TLDs as Al2O3:C and TLD-100 (LiF: Mg, Ti) and ICRU tissue data. The influence of the dopant concentration in the MgB4O7 matrix on the energy dependence of TLD was also investigated. The analyses indicated a good agreement between the simulations and theoretical calculations. The μen/ρ and energy dependence of the materials are higher in the low energy range (E < 100 keV), which is related to the high probability of interaction between radiation and matter due to photoelectric absorption. With regard to the influence of dysprosium concentration in the MgB4O7 matrix an increase in the energy dependence of MgB4O7 for higher concentrations of dopants was observed in the low energy range.
  • Artigo IPEN-doc 25797
    Monte Carlo modeling of a holder for irradiation of dosimeters in beta radiation beams
    2019 - POLO, IVON O.; SANTOS, WILLIAM S.; CALDAS, LINDA V.E.
    A study of the influence of a dosimetric holder and its cover for the irradiation of the dosimeters in the Beta Secondary Standard BSS2 radiation fields is reported. The correction factors for attenuation or scattering were calculated taking into account the BSS2 beta source energy, as well as the detector source distance. The study and the determination of these factors were carried out using the Monte Carlo Method. The results of the correction factors showed that the absorption and scattering of the electrons depend greatly on the energy of beta radionuclides. The determined correction factors are in agreement with the international report ISO 6980.
  • Artigo IPEN-doc 25131
    Modelling the absorbed dose rate of the beta standard BSS2 147Pm source
    2018 - POLO, IVON O.; SANTOS, WILLIAM S.; CALDAS, LINDA V.E.
    The dosimetric measurements of 147Pm beta radiation beams have limitations due to their low energy, low dose rate, great dispersion and attenuation in air or tissue. In this work, the Monte Carlo model was developed for a 147Pm absorbed dose rate determination. This model consists of an extrapolation chamber and a 147Pm beta radiation source. Moreover, the absorbed dose rate was determined by experimental measurements and the MCNP Monte Carlo code was used. The relative number of particles that crossed the radioactive source window and the particles that crossed the extrapolation chamber entrance window were determined. The source fluence spectrum was also determined. The results of the simulation and the experimental calculations are in agreement with the absorbed dose rate from the PTB calibration certificate. The results obtained are considered acceptable, and they agree within the uncertainties. The difference between the experimental result and that from the Monte Carlo model, compared to that from the calibration certificate, was only 0.8% in both cases.
  • Artigo IPEN-doc 25130
    Determination of correction factors in beta radiation beams using Monte Carlo method
    2018 - POLO, IVON O.; SANTOS, WILLIAM de S.; CALDAS, LINDA V.E.
    The absorbed dose rate is the main characterization quantity for beta radiation. The extrapolation chamber is considered the primary standard instrument. To determine absorbed dose rates in beta radiation beams, it is necessary to establish several correction factors. In this work, the correction factors for the backscatter due to the collecting electrode and to the guard ring, and the correction factor for Bremsstrahlung in beta secondary standard radiation beams are presented. For this purpose, the Monte Carlo method was applied. The results obtained are considered acceptable, and they agree within the uncertainties. The differences between the backscatter factors determined by the Monte Carlo method and those of the ISO standard were 0.6%, 0.9% and 2.04% for 90Sr/90Y, 85Kr and 147Pm sources respectively. The differences between the Bremsstrahlung factors determined by the Monte Carlo method and those of the ISO were 0.25%, 0.6% and 1% for 90Sr/90Y, 85Kr and 147Pm sources respectively.