Characterization and calibration of thermoluminescent dosimeters of LiF:Mg, Ti in the quantity Hp(0.07)
dc.contributor.author | NASCIMENTO, G.G. | pt_BR |
dc.contributor.author | CAMPOS, V.P. | pt_BR |
dc.contributor.author | CAMPOS, L.L. | pt_BR |
dc.coverage | Nacional | pt_BR |
dc.date.accessioned | 2022-12-20T15:27:01Z | |
dc.date.available | 2022-12-20T15:27:01Z | |
dc.date.issued | 2022 | pt_BR |
dc.description.abstract | The extremity dosimeters are devices used to quantifying the radiation dose that the occupationally exposed individual receives in specific regions of the body during the work time. Dosimeter calibration is essential so that the dosimeter response is equivalent to the received dose. Tests such as batch homogeneity and lower detection limit are part of the dosimeter calibration process. The rod phantom simulates the region of interest regarding the interaction with radiation and the scattered dose. The extremity dosimeters used were the LiF:Mg,Ti thermoluminescent dosimeters. | pt_BR |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | pt_BR |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | pt_BR |
dc.description.sponsorshipID | FAPESP: 18/05982-0 | pt_BR |
dc.description.sponsorshipID | CNPq: 426513/2018-5 | pt_BR |
dc.format.extent | 1-6 | pt_BR |
dc.identifier.citation | NASCIMENTO, G.G.; CAMPOS, V.P.; CAMPOS, L.L. Characterization and calibration of thermoluminescent dosimeters of LiF:Mg, Ti in the quantity Hp(0.07). <b>Brazilian Journal of Radiation Sciences</b>, v. 10, n. 3B, p. 1-6, 2022. DOI: <a href="https://dx.doi.org/10.15392/2319-0612.2022.1786">10.15392/2319-0612.2022.1786</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/33510. | |
dc.identifier.doi | 10.15392/2319-0612.2022.1786 | pt_BR |
dc.identifier.fasciculo | 3B | pt_BR |
dc.identifier.issn | 2319-0612 | pt_BR |
dc.identifier.orcid | 0000-0001-7137-0613 | pt_BR |
dc.identifier.orcid | https://orcid.org/0000-0001-7137-0613 | |
dc.identifier.percentilfi | Sem Percentil | pt_BR |
dc.identifier.percentilfiCiteScore | Sem Percentil CiteScore | pt_BR |
dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/33510 | |
dc.identifier.vol | 10 | pt_BR |
dc.relation.ispartof | Brazilian Journal of Radiation Sciences | pt_BR |
dc.rights | openAccess | pt_BR |
dc.source | Meeting on Nuclear Applications (ENAN), 15th, November 29 - December 2, 2021, Online | pt_BR |
dc.subject | calibration | |
dc.subject | cesium 137 | |
dc.subject | dosimetry | |
dc.subject | irradiation | |
dc.subject | lithium fluorides | |
dc.subject | phantoms | |
dc.subject | recommendations | |
dc.subject | rings | |
dc.subject | rods | |
dc.subject | thermoluminescent dosemeters | |
dc.title | Characterization and calibration of thermoluminescent dosimeters of LiF:Mg, Ti in the quantity Hp(0.07) | pt_BR |
dc.type | Artigo de periódico | pt_BR |
dspace.entity.type | Publication | |
ipen.autor | LETICIA LUCENTE CAMPOS RODRIGUES | |
ipen.autor | VICENTE DE PAULO DE CAMPOS | |
ipen.autor | GABRIEL GOMES DO NASCIMENTO | |
ipen.codigoautor | 1195 | |
ipen.codigoautor | 753 | |
ipen.codigoautor | 14794 | |
ipen.contributor.ipenauthor | LETICIA LUCENTE CAMPOS RODRIGUES | |
ipen.contributor.ipenauthor | VICENTE DE PAULO DE CAMPOS | |
ipen.contributor.ipenauthor | GABRIEL GOMES DO NASCIMENTO | |
ipen.date.recebimento | 22-12 | |
ipen.identifier.fi | Sem F.I. | pt_BR |
ipen.identifier.fiCiteScore | Sem CiteScore | pt_BR |
ipen.identifier.ipendoc | 29144 | pt_BR |
ipen.type.genre | Artigo | |
relation.isAuthorOfPublication | d4d34119-a6e6-4026-9a67-7b16d8b668da | |
relation.isAuthorOfPublication | 5d1e1489-cd98-41a8-b4b3-0adef2712441 | |
relation.isAuthorOfPublication | ef601e21-998c-4d4d-9aee-c0f8dbc84c10 | |
relation.isAuthorOfPublication.latestForDiscovery | ef601e21-998c-4d4d-9aee-c0f8dbc84c10 | |
sigepi.autor.atividade | CAMPOS, L.L.:1195:330:N | pt_BR |
sigepi.autor.atividade | CAMPOS, V.P.:753:330:N | pt_BR |
sigepi.autor.atividade | NASCIMENTO, G.G.:14794:330:S | pt_BR |