Radiochemical purity determination of technetium (99m)Tc-sestamibi by high performance liquid chromatography (HPLC)
dc.contributor.author | MARTINS, PATRICIA de A. | pt_BR |
dc.contributor.author | FUKUMORI, NEUZA T.O. | pt_BR |
dc.contributor.author | SILVA, NATANAEL G. da | pt_BR |
dc.contributor.author | MATSUDA, MARGARETH M.N. | pt_BR |
dc.coverage | Internacional | pt_BR |
dc.creator.evento | INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE | pt_BR |
dc.date.accessioned | 2020-01-07T13:50:26Z | |
dc.date.available | 2020-01-07T13:50:26Z | |
dc.date.evento | October 21-25, 2019 | pt_BR |
dc.description.abstract | The assessment of the extent of reversible or irreversible mitochondrial damage after myocardial ischemia is performed by obtaining myocardial perfusion SPECT-CT images of Technetium-99m Sestamibi radiopharmaceutical (99mTc-2-methoxy-isobutyl-isonitrile; 99mTc-sestamibi; 99mTc-MIBI). For quality control purposes, the monograph of the United States Pharmacopoeia (USP) was followed. The determination of the radiochemical purity of 99mTc-sestamibi involves the use of two chromatographic methods: thin layer chromatography in reverse phase and high performance liquid chromatography. This work aims to determine the radiochemical purity of 99mTc-sestamibi by the HPLC method described in USP. The analyses were performed on a Shimadzu liquid chromatography, LC-20AT model, consisting of two pumps, degasser, automatic sample injector, UV-visible detector and Bioscan radioactivity detector. The column used was μBondapack C18 (3.9 x 300 mm, 10 μm, Waters) and the mobile phase was a mixture of acetonitrile, 0.05 mol L-1 ammonium sulfate and methanol (20:35:45). 5 μL of sample (approximately 250 μCi) was injected with a 2 mL min-1 mobile phase flow. According to the USP monograph, the retention time for 99mTc-sestamibi is 5-10 minutes and for the 99mTc-pentamibidimethylvinylisonitrile impurity is 6-13 minutes. Not less than 90% of the total radioactivity must be present as 99mTc-sestamibi and not more than 5% as 99mTc-pentamibidimethylvinylisonitrile. For 12 analyzed batches of MIBI-TEC® produced at IPEN/CNEN-SP, the product presented a retention time of 7 minutes and the 99mTc-pentamibidimethylvinylisonitrile impurity formation was not observed. | pt_BR |
dc.event.sigla | INAC | pt_BR |
dc.format.extent | 1855-1859 | pt_BR |
dc.identifier.citation | MARTINS, PATRICIA de A.; FUKUMORI, NEUZA T.O.; SILVA, NATANAEL G. da; MATSUDA, MARGARETH M.N. Radiochemical purity determination of technetium (99m)Tc-sestamibi by high performance liquid chromatography (HPLC). In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. <b>Proceedings...</b> Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 1855-1859. Disponível em: http://repositorio.ipen.br/handle/123456789/30588. | |
dc.identifier.orcid | 0000-0003-4455-3486 | pt_BR |
dc.identifier.orcid | https://orcid.org/0000-0003-4455-3486 | |
dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/30588 | |
dc.local | Rio de Janeiro | pt_BR |
dc.local.evento | Santos, SP | pt_BR |
dc.publisher | Associação Brasileira de Energia Nuclear | |
dc.rights | openAccess | pt_BR |
dc.subject | high-performance liquid chromatography | |
dc.subject | quality control | |
dc.subject | radiochemical analysis | |
dc.subject | single photon emission computed tomography | |
dc.subject | technetium 99 | |
dc.title | Radiochemical purity determination of technetium (99m)Tc-sestamibi by high performance liquid chromatography (HPLC) | pt_BR |
dc.type | Texto completo de evento | pt_BR |
dspace.entity.type | Publication | |
ipen.autor | MARGARETH MIE NAKAMURA MATSUDA | |
ipen.autor | NATANAEL GOMES DA SILVA | |
ipen.autor | NEUZA TAEKO OKASAKI FUKUMORI | |
ipen.autor | PATRICIA DE ANDRADE MARTINS | |
ipen.codigoautor | 841 | |
ipen.codigoautor | 750 | |
ipen.codigoautor | 1514 | |
ipen.codigoautor | 965 | |
ipen.contributor.ipenauthor | MARGARETH MIE NAKAMURA MATSUDA | |
ipen.contributor.ipenauthor | NATANAEL GOMES DA SILVA | |
ipen.contributor.ipenauthor | NEUZA TAEKO OKASAKI FUKUMORI | |
ipen.contributor.ipenauthor | PATRICIA DE ANDRADE MARTINS | |
ipen.date.recebimento | 20-01 | |
ipen.event.datapadronizada | 2019 | pt_BR |
ipen.identifier.ipendoc | 26238 | pt_BR |
ipen.notas.internas | Proceedings | pt_BR |
ipen.type.genre | Artigo | |
relation.isAuthorOfPublication | fa01cabc-d76d-45ee-bb21-4994c14ba167 | |
relation.isAuthorOfPublication | 7374d7a3-3ba1-4852-b93d-e578e851abd1 | |
relation.isAuthorOfPublication | ab0b8070-073b-490b-bc03-17888a1c4f1d | |
relation.isAuthorOfPublication | 0fd86237-824c-4605-9f62-9ede89aef62d | |
relation.isAuthorOfPublication.latestForDiscovery | 0fd86237-824c-4605-9f62-9ede89aef62d | |
sigepi.autor.atividade | MATSUDA, MARGARETH M.N.:841:110:N | pt_BR |
sigepi.autor.atividade | SILVA, NATANAEL G. da:750:110:N | pt_BR |
sigepi.autor.atividade | FUKUMORI, NEUZA T.O.:1514:120:N | pt_BR |
sigepi.autor.atividade | MARTINS, PATRICIA de A.:965:120:S | pt_BR |