Time response measurements of rosemount pressure transmitters (model 3154) OF Angra I Power Plant

dc.contributor.authorSANTOS, ROBERTO C. dos
dc.contributor.authorPEREIRA, IRACI M.
dc.contributor.authorJUSTINO, MARCELO C.
dc.contributor.authorSILVA, MARCOS C.
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL NUCLEAR ATLANTIC CONFERENCEpt_BR
dc.date.accessioned2018-01-03T17:23:33Z
dc.date.available2018-01-03T17:23:33Z
dc.date.eventoOctober 22-27, 2017pt_BR
dc.description.abstractThis paper shows the Response of time five Rosemount model 3154N pressure trnasmiter from the Angra I Nuclear Power Plant. The tests were performed using the Hydraulic Ramp and Pressure Step Generator from the Sensor Response Time Measurement laboratory of CEN - Nuclear Engineering Center of IPEN. For each transmitter, damping was adjusted so that the time constant was less than or equal to 500 ms. This value has been determined so that the total value of the protection chain response time does not exceed the established maximum value of 2 seconds. For each transmitter ten tests were performed, obtaining mean values of time constant of 499.7 ms, 464.1 ms, 473.8 ms, 484.7 ms and 511.5 ms, with mean deviations 0.85%, 0.24%, 0.97%, 1.26% and 0.64% respectively.pt_BR
dc.event.siglaINACpt_BR
dc.identifier.citationSANTOS, ROBERTO C. dos; PEREIRA, IRACI M.; JUSTINO, MARCELO C.; SILVA, MARCOS C. Time response measurements of rosemount pressure transmitters (model 3154) OF Angra I Power Plant. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. <b>Proceedings...</b> Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017. Disponível em: http://repositorio.ipen.br/handle/123456789/28209.
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/28209
dc.localRio de Janeiro, RJpt_BR
dc.local.eventoBelo Horizonte, MGpt_BR
dc.publisherAssociação Brasileira de Energia Nuclearpt_BR
dc.rightsopenAccesspt_BR
dc.subjectdamping
dc.subjecthydraulics
dc.subjectnuclear power plants
dc.subjectperformance testing
dc.subjectpressure measurement
dc.subjectresponse functions
dc.subjectsensors
dc.subjecttime measurement
dc.subjectangra-1 reactor
dc.titleTime response measurements of rosemount pressure transmitters (model 3154) OF Angra I Power Plantpt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorIRACI MARTINEZ PEREIRA GONCALVES
ipen.autorROBERTO CARLOS DOS SANTOS
ipen.codigoautor1058
ipen.codigoautor499
ipen.contributor.ipenauthorIRACI MARTINEZ PEREIRA GONCALVES
ipen.contributor.ipenauthorROBERTO CARLOS DOS SANTOS
ipen.date.recebimento18-01pt_BR
ipen.event.datapadronizada2017pt_BR
ipen.identifier.ipendoc24034pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication68c7c73d-2c58-4074-901c-36d1e763d624
relation.isAuthorOfPublication327648c2-5283-4511-856f-4dcdb67d3908
relation.isAuthorOfPublication.latestForDiscovery327648c2-5283-4511-856f-4dcdb67d3908
sigepi.autor.atividadeSANTOS, ROBERTO C. DOS:499:420:Spt_BR
sigepi.autor.atividadePEREIRA, IRACI M.:1058:420:Npt_BR
Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
24034.pdf
Tamanho:
2.35 MB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Coleções