Evaluation of 99Mo/99mTc generator columns after irradiation with different absorbed doses
dc.contributor.author | FUKUMORI, NEUZA T.O. | |
dc.contributor.author | MENGATTI, JAIR | |
dc.contributor.author | MATSUDA, MARGARETH M.N. | |
dc.coverage | Internacional | pt_BR |
dc.creator.evento | INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE | pt_BR |
dc.date.accessioned | 2018-01-11T11:03:39Z | |
dc.date.available | 2018-01-11T11:03:39Z | |
dc.date.evento | October 22-27, 2017 | pt_BR |
dc.description.abstract | The 99Mo/99mTc generator is widely used in nuclear medicine and it consists of a glass column containing Teflon® strips and alumina in which 99Mo produced by 235U fission is adsorbed. The 99mTcO4- eluate shall meet the sterile and pyrogen free conditions for injectable radiopharmaceuticals as determined by the Good Manufacturing Practices. The purpose of this study was to evaluate the feasibility of using gamma radiation in the sterilization of the 99Mo/99mTc generator column and the influence on the elution efficiency. Alumina-containing columns were irradiated with 10, 15, 25 and 50 kGy absorbed doses. Alumina samples and control (non-irradiated) were submitted to X-ray diffraction and the combined use of scanning electron microscopy and elemental analysis. Teflon® samples were evaluated by thermogravimetry (TGA) and differential scanning calorimetry (DSC). X-ray diffractograms and micrographies with elemental analysis showed no significant changes in the crystalline structure of the alumina because it was stable α-Al2O3. TGA demonstrated that higher doses showed changes in lower temperatures and times than the control material. For DSC the higher the absorbed dose, the greater the polymer chain breakage and crosslinking in the material. The generator system without radioactivity was set up with the irradiated columns and the eluates demonstrated to be sterile and pyrogen free. The effects of different absorbed doses on the generator column, although some reported changes in the materials, demonstrated that the sterilization of the columns by irradiation with gamma rays as an alternative to wet heat sterilization is feasible from a technical and financial point of view. | pt_BR |
dc.event.sigla | INAC | pt_BR |
dc.identifier.citation | FUKUMORI, NEUZA T.O.; MENGATTI, JAIR; MATSUDA, MARGARETH M.N. Evaluation of 99Mo/99mTc generator columns after irradiation with different absorbed doses. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. <b>Proceedings...</b> Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017. Disponível em: http://repositorio.ipen.br/handle/123456789/28282. | |
dc.identifier.orcid | https://orcid.org/0000-0003-4455-3486 | |
dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/28282 | |
dc.local | Rio de Janeiro, RJ | pt_BR |
dc.local.evento | Belo Horizonte, MG | pt_BR |
dc.publisher | Associação Brasileira de Energia Nuclear | pt_BR |
dc.rights | openAccess | pt_BR |
dc.subject | absorbed radiation doses | |
dc.subject | aluminium oxides | |
dc.subject | calorimetry | |
dc.subject | cobalt 60 | |
dc.subject | feasibility studies | |
dc.subject | molybdenum 99 | |
dc.subject | radioisotope generators | |
dc.subject | sterilization | |
dc.subject | technetium 99 | |
dc.subject | thermal gravimetric analysis | |
dc.title | Evaluation of 99Mo/99mTc generator columns after irradiation with different absorbed doses | pt_BR |
dc.type | Texto completo de evento | pt_BR |
dspace.entity.type | Publication | |
ipen.autor | MARGARETH MIE NAKAMURA MATSUDA | |
ipen.autor | JAIR MENGATTI | |
ipen.autor | NEUZA TAEKO OKASAKI FUKUMORI | |
ipen.codigoautor | 841 | |
ipen.codigoautor | 1498 | |
ipen.codigoautor | 1514 | |
ipen.contributor.ipenauthor | MARGARETH MIE NAKAMURA MATSUDA | |
ipen.contributor.ipenauthor | JAIR MENGATTI | |
ipen.contributor.ipenauthor | NEUZA TAEKO OKASAKI FUKUMORI | |
ipen.date.recebimento | 18-01 | pt_BR |
ipen.event.datapadronizada | 2017 | pt_BR |
ipen.identifier.ipendoc | 24107 | pt_BR |
ipen.notas.internas | Proceedings | pt_BR |
ipen.type.genre | Artigo | |
relation.isAuthorOfPublication | fa01cabc-d76d-45ee-bb21-4994c14ba167 | |
relation.isAuthorOfPublication | 4722b83e-1d23-488f-b497-6a72d3048679 | |
relation.isAuthorOfPublication | ab0b8070-073b-490b-bc03-17888a1c4f1d | |
relation.isAuthorOfPublication.latestForDiscovery | ab0b8070-073b-490b-bc03-17888a1c4f1d | |
sigepi.autor.atividade | FUKUMORI, NEUZA T.O.:1514:110:S | pt_BR |
sigepi.autor.atividade | MENGATTI, JAIR:1498:110:N | pt_BR |
sigepi.autor.atividade | MATSUDA, MARGARETH M.N.:841:110:N | pt_BR |