Evaluation of 99Mo/99mTc generator columns after irradiation with different absorbed doses

dc.contributor.authorFUKUMORI, NEUZA T.O.
dc.contributor.authorMENGATTI, JAIR
dc.contributor.authorMATSUDA, MARGARETH M.N.
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL NUCLEAR ATLANTIC CONFERENCEpt_BR
dc.date.accessioned2018-01-11T11:03:39Z
dc.date.available2018-01-11T11:03:39Z
dc.date.eventoOctober 22-27, 2017pt_BR
dc.description.abstractThe 99Mo/99mTc generator is widely used in nuclear medicine and it consists of a glass column containing Teflon® strips and alumina in which 99Mo produced by 235U fission is adsorbed. The 99mTcO4- eluate shall meet the sterile and pyrogen free conditions for injectable radiopharmaceuticals as determined by the Good Manufacturing Practices. The purpose of this study was to evaluate the feasibility of using gamma radiation in the sterilization of the 99Mo/99mTc generator column and the influence on the elution efficiency. Alumina-containing columns were irradiated with 10, 15, 25 and 50 kGy absorbed doses. Alumina samples and control (non-irradiated) were submitted to X-ray diffraction and the combined use of scanning electron microscopy and elemental analysis. Teflon® samples were evaluated by thermogravimetry (TGA) and differential scanning calorimetry (DSC). X-ray diffractograms and micrographies with elemental analysis showed no significant changes in the crystalline structure of the alumina because it was stable α-Al2O3. TGA demonstrated that higher doses showed changes in lower temperatures and times than the control material. For DSC the higher the absorbed dose, the greater the polymer chain breakage and crosslinking in the material. The generator system without radioactivity was set up with the irradiated columns and the eluates demonstrated to be sterile and pyrogen free. The effects of different absorbed doses on the generator column, although some reported changes in the materials, demonstrated that the sterilization of the columns by irradiation with gamma rays as an alternative to wet heat sterilization is feasible from a technical and financial point of view.pt_BR
dc.event.siglaINACpt_BR
dc.identifier.citationFUKUMORI, NEUZA T.O.; MENGATTI, JAIR; MATSUDA, MARGARETH M.N. Evaluation of 99Mo/99mTc generator columns after irradiation with different absorbed doses. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. <b>Proceedings...</b> Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017. Disponível em: http://repositorio.ipen.br/handle/123456789/28282.
dc.identifier.orcidhttps://orcid.org/0000-0003-4455-3486
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/28282
dc.localRio de Janeiro, RJpt_BR
dc.local.eventoBelo Horizonte, MGpt_BR
dc.publisherAssociação Brasileira de Energia Nuclearpt_BR
dc.rightsopenAccesspt_BR
dc.subjectabsorbed radiation doses
dc.subjectaluminium oxides
dc.subjectcalorimetry
dc.subjectcobalt 60
dc.subjectfeasibility studies
dc.subjectmolybdenum 99
dc.subjectradioisotope generators
dc.subjectsterilization
dc.subjecttechnetium 99
dc.subjectthermal gravimetric analysis
dc.titleEvaluation of 99Mo/99mTc generator columns after irradiation with different absorbed dosespt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorMARGARETH MIE NAKAMURA MATSUDA
ipen.autorJAIR MENGATTI
ipen.autorNEUZA TAEKO OKASAKI FUKUMORI
ipen.codigoautor841
ipen.codigoautor1498
ipen.codigoautor1514
ipen.contributor.ipenauthorMARGARETH MIE NAKAMURA MATSUDA
ipen.contributor.ipenauthorJAIR MENGATTI
ipen.contributor.ipenauthorNEUZA TAEKO OKASAKI FUKUMORI
ipen.date.recebimento18-01pt_BR
ipen.event.datapadronizada2017pt_BR
ipen.identifier.ipendoc24107pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublicationfa01cabc-d76d-45ee-bb21-4994c14ba167
relation.isAuthorOfPublication4722b83e-1d23-488f-b497-6a72d3048679
relation.isAuthorOfPublicationab0b8070-073b-490b-bc03-17888a1c4f1d
relation.isAuthorOfPublication.latestForDiscoveryab0b8070-073b-490b-bc03-17888a1c4f1d
sigepi.autor.atividadeFUKUMORI, NEUZA T.O.:1514:110:Spt_BR
sigepi.autor.atividadeMENGATTI, JAIR:1498:110:Npt_BR
sigepi.autor.atividadeMATSUDA, MARGARETH M.N.:841:110:Npt_BR
Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
24107.pdf
Tamanho:
744.34 KB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Coleções