Equivalence between Solid Water and printed ABS plates for 6 MV clinical photon beam - an assessment using thermoluminescent dosimetry

dc.contributor.authorVALERIANO, C.C.S.
dc.contributor.authorMORENO, C.S.
dc.contributor.authorCORREA, E.L.
dc.contributor.authorSAKURABA, R.K.
dc.contributor.authorCAMPOS, L.L.
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL CONFERENCE ON LUMINESCENCE, 18thpt_BR
dc.date.accessioned2018-03-09T13:29:58Z
dc.date.available2018-03-09T13:29:58Z
dc.date.eventoAugust 27 - September 01, 2017pt_BR
dc.description.abstractThree dimensional models of anatomical structures produced by rapid prototyping are being adopted for medical application as hemodynamics studies and maxillofacial surgery planning. Models with geometrical accuracy can be achieved using medical images as MRI or CT and produced using polyurethane, polylactic acid and epoxy resins. Changing materials and densities is possible achieve the desired tissue-equivalence[1]. This work was developed in order to analyze the equivalence between the printed ABS and the Solid Water, by using the thermoluminescent dosimetry, in order to evaluate the viability of build a phantom for radiotherapy with a 3D printer. The ABS plates with different thickness used in this study were printed using a 3D Printer model UP Plus 2, making use of the higher quality of impression (“Solid Honeycomb”[2]) which gives the strongest printed part. Solid water RMI-457 plates with different thickness were used as standard material. In order to analyze the results obtained by the measurements done with the TLDs it was done the planning of the irradiations using the planning treatment system EclipseTM. The Analytical Anisotropic Algorithm (AAA) was applied to perform the calculus of absorbed dose. The comparison between the dose calculated by the AAA and the dose measured by TLD showed that the percentage between them was higher than 5%[3]. The calculus of the dose it was redone using the Acuros XB advanced dose calculation (AXB), presenting a difference less than 3% in all measured depths. The depth dose percentage was then calculated. Comparing the depth dose for Solid Water and for ABS will be noted that the ABS seems not to have equivalence with the Solid Water since differences are higher than 5%, but it is not possible to affirm yet that ABS cannot be used to produce phantoms for clinical dosimetry. It is necessary to develop a phantom with different print qualities or using more than one printed material (e. g. printed PLA) to achieve the desired attenuation/scattering of the radiation.pt_BR
dc.event.siglaICLpt_BR
dc.format.extent245-245pt_BR
dc.identifier.citationVALERIANO, C.C.S.; MORENO, C.S.; CORREA, E.L.; SAKURABA, R.K.; CAMPOS, L.L. Equivalence between Solid Water and printed ABS plates for 6 MV clinical photon beam - an assessment using thermoluminescent dosimetry. In: INTERNATIONAL CONFERENCE ON LUMINESCENCE, 18th, August 27 - September 01, 2017, João Pessoa, PB. <b>Abstract...</b> p. 245-245. Disponível em: http://repositorio.ipen.br/handle/123456789/28683.
dc.identifier.orcidhttps://orcid.org/0000-0001-7137-0613
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/28683
dc.local.eventoJoão Pessoa, PBpt_BR
dc.rightsopenAccesspt_BR
dc.titleEquivalence between Solid Water and printed ABS plates for 6 MV clinical photon beam - an assessment using thermoluminescent dosimetrypt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.autorEDUARDO DE LIMA CORREA
ipen.autorCAIO CESAR SANTOS VALERIANO
ipen.codigoautor1195
ipen.codigoautor7498
ipen.codigoautor14091
ipen.contributor.ipenauthorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.contributor.ipenauthorEDUARDO DE LIMA CORREA
ipen.contributor.ipenauthorCAIO CESAR SANTOS VALERIANO
ipen.date.recebimento18-03pt_BR
ipen.event.datapadronizada2017pt_BR
ipen.identifier.ipendoc24506pt_BR
ipen.notas.internasAbstractpt_BR
ipen.type.genreResumo
relation.isAuthorOfPublicationd4d34119-a6e6-4026-9a67-7b16d8b668da
relation.isAuthorOfPublication1f00087b-0c1b-413b-8464-2842b24a7328
relation.isAuthorOfPublicationafc1c760-7846-46cd-b99b-9af3768ae99e
relation.isAuthorOfPublication.latestForDiscoveryafc1c760-7846-46cd-b99b-9af3768ae99e
sigepi.autor.atividadeVALERIANO, C.C.S.:14091:330:Spt_BR
sigepi.autor.atividadeCORREA, E.L.:7498:330:Npt_BR
sigepi.autor.atividadeCAMPOS, L.L.:1195:330:Npt_BR
Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
24506.pdf
Tamanho:
296.66 KB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: