OSL response bleaching of BeO samples, using fluorescent light and blue LEDs
dc.contributor.author | GROPPO, DANIELA P. | |
dc.contributor.author | CALDAS, LINDA V.E. | |
dc.coverage | Internacional | pt_BR |
dc.creator.evento | BRAZILIAN CONGRESS ON METROLOGY, 8th | pt_BR |
dc.date.accessioned | 2017-03-20T11:17:16Z | |
dc.date.available | 2017-03-20T11:17:16Z | |
dc.date.evento | 29 de novembro - 04 de dezembro, 2015 | pt_BR |
dc.description.abstract | The optically stimulated luminescence (OSL) is widely used as a dosimetric technique for many applications. In this work, the OSL response bleaching of BeO samples was studied. The samples were irradiated using a beta radiation source (90Sr+90Y); the bleaching treatments (fluorescent light and blue LEDs) were performed, and the results were compared. Various optical treatment time intervals were tested until reaching the complete bleaching of the OSL response. The best combination of the time interval and bleaching type was analyzed. | pt_BR |
dc.format.extent | 1-5 | pt_BR |
dc.identifier.citation | GROPPO, DANIELA P.; CALDAS, LINDA V.E. OSL response bleaching of BeO samples, using fluorescent light and blue LEDs. In: BRAZILIAN CONGRESS ON METROLOGY, 8th, 29 de novembro - 04 de dezembro, 2015, Bento Gonçalves, RS. <b>Proceedings...</b> p. 1-5. Disponível em: http://repositorio.ipen.br/handle/123456789/27216. | |
dc.identifier.orcid | https://orcid.org/0000-0002-7362-2455 | |
dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/27216 | |
dc.local.evento | Bento Gonçalves, RS | pt_BR |
dc.publisher | Bristol, UK: IOP Publishing | pt_BR |
dc.rights | openAccess | pt_BR |
dc.source | Journal of Physics: Conference Series, v. 733, 2016 | pt_BR |
dc.subject | beryllium oxides | |
dc.subject | beta sources | |
dc.subject | bleaching | |
dc.subject | comparative evaluations | |
dc.subject | fluorescent lamps | |
dc.subject | irradiation | |
dc.subject | light emitting diodes | |
dc.subject | luminescent dosemeters | |
dc.subject | performance | |
dc.subject | time interval analyzers | |
dc.title | OSL response bleaching of BeO samples, using fluorescent light and blue LEDs | pt_BR |
dc.type | Texto completo de evento | pt_BR |
dspace.entity.type | Publication | |
ipen.autor | LINDA V. E. CALDAS | |
ipen.autor | DANIELA PIAI GROPPO | |
ipen.codigoautor | 1495 | |
ipen.codigoautor | 9729 | |
ipen.contributor.ipenauthor | LINDA V. E. CALDAS | |
ipen.contributor.ipenauthor | DANIELA PIAI GROPPO | |
ipen.date.recebimento | 17-03 | pt_BR |
ipen.event.datapadronizada | 2016 | pt_BR |
ipen.identifier.ipendoc | 23571 | pt_BR |
ipen.notas.internas | Proceedings | pt_BR |
ipen.type.genre | Artigo | |
relation.isAuthorOfPublication | 7f46d4f4-dfd6-4485-a767-10df5b4f4f13 | |
relation.isAuthorOfPublication | a092c2d5-0541-4e14-a0f5-14c414026dbe | |
relation.isAuthorOfPublication.latestForDiscovery | a092c2d5-0541-4e14-a0f5-14c414026dbe | |
sigepi.autor.atividade | GROPPO, DANIELA P.:9729:-1:S | pt_BR |
sigepi.autor.atividade | CALDAS, LINDA V.E.:1495:330:N | pt_BR |