Resumo
IEA-R1 is a 5MW pool-type research reactor built in the late 1950's. In the last years, it operates at
4.5MW for 8h on Mondays, Tuesdays and Wednesdays. In every day of operation, a sample is taken
from the pool water both before starting the reactor and at the end of the day and analyzed in an HPGe
detector, in order to verify for possible problems with the fuel elements or other issues. In this work, the
results obtained in these analyses spanning for some months are discussed regarding the radionuclides
frequently identi ed and the dependence of their activities with time.
Como referenciar
TICIANELLI, REGINA B.; ZAHN, GUILHERME S.; SILVA, PAULO S.C. da; GENEZINI, FREDERICO A. Radionuclide analysis of the IEA-R1 pool water. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 579-583. Disponível em: http://repositorio.ipen.br/handle/123456789/30410. Acesso em: 11 May 2024.