Assessment of energy and angular dependence of LiF:Mg,Ti dosimeters irradiated in the quantity Hp(0.07)

dc.contributor.authorNASCIMENTO, G.G.
dc.contributor.authorSILVA, C.R.
dc.contributor.authorCAMPOS, V.P.
dc.contributor.authorCAMPOS, L.L.
dc.coverageNacional
dc.date.accessioned2024-03-04T16:51:05Z
dc.date.available2024-03-04T16:51:05Z
dc.date.issued2023
dc.description.abstractRadiation dosimetry has the purpose of quantifying the dose received by the occupationally exposed individual. The device used in this process is called a dosimeter, the dosimeter can be used in different situations, for example, the dosimeter used to quantify the dose received in the fingers is the ring model dosimeter, for the extremity, which is the focus of this work. In Brazil, we still do not have standards for the calibration of extremity dosimeters, therefore, in this work, the CASEC recommendations were used, adapted for extremity dosimetry. For a dosimeter to be used in its respective routine, it must present results within some preestablished limits in reference standards. For this purpose, energy dependence and angular dependence tests were carried out. To calibrate the LiF:Mg,Ti thermoluminescent dosimeters, a phantom rod was used. The phantom rod has the function of simulating the region of interest, in the case of this work, the fingers. The dosimeters were irradiated in the magnitude Hp(0.07), with the doses and energies recommended by the CASEC standard. The aim of this work is to characterize end dosimeters in the ring model with LiF:Mg,Ti detectors.
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipIDFAPESP: 18/05982-0
dc.description.sponsorshipIDCNPq: 426513/2018-5
dc.format.extent1-11
dc.identifier.citationNASCIMENTO, G.G.; SILVA, C.R.; CAMPOS, V.P.; CAMPOS, L.L. Assessment of energy and angular dependence of LiF:Mg,Ti dosimeters irradiated in the quantity Hp(0.07). <b>Brazilian Journal of Radiation Sciences</b>, v. 11, n. 1A, p. 1-11, 2023. DOI: <a href="https://dx.doi.org/10.15392/2319-0612.2023.2142">10.15392/2319-0612.2023.2142</a>. Disponível em: https://repositorio.ipen.br/handle/123456789/47885.
dc.identifier.doi10.15392/2319-0612.2023.2142
dc.identifier.fasciculo1A
dc.identifier.issn2319-0612
dc.identifier.orcidhttps://orcid.org/0000-0001-7137-0613
dc.identifier.percentilfiSem Percentil
dc.identifier.percentilfiCiteScoreSem Percentil CiteScore
dc.identifier.urihttps://repositorio.ipen.br/handle/123456789/47885
dc.identifier.vol11
dc.relation.ispartofBrazilian Journal of Radiation Sciences
dc.rightsopenAccess
dc.subjectdosimetry
dc.subjectradiations
dc.subjectfingers
dc.subjectradiation protection
dc.subjectoccupational exposure
dc.subjectlithium fluorides
dc.subjectmagnesium
dc.subjectthermoluminescent dosimetry
dc.titleAssessment of energy and angular dependence of LiF:Mg,Ti dosimeters irradiated in the quantity Hp(0.07)
dc.typeArtigo de periódico
dspace.entity.typePublication
ipen.autorGABRIEL GOMES DO NASCIMENTO
ipen.autorVICENTE DE PAULO DE CAMPOS
ipen.autorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.codigoautor14794
ipen.codigoautor753
ipen.codigoautor1195
ipen.contributor.ipenauthorGABRIEL GOMES DO NASCIMENTO
ipen.contributor.ipenauthorVICENTE DE PAULO DE CAMPOS
ipen.contributor.ipenauthorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.identifier.fiSem F.I.
ipen.identifier.fiCiteScoreSem CiteScore
ipen.identifier.ipendoc30218
ipen.type.genreArtigo
relation.isAuthorOfPublicationef601e21-998c-4d4d-9aee-c0f8dbc84c10
relation.isAuthorOfPublication5d1e1489-cd98-41a8-b4b3-0adef2712441
relation.isAuthorOfPublicationd4d34119-a6e6-4026-9a67-7b16d8b668da
relation.isAuthorOfPublication.latestForDiscoveryef601e21-998c-4d4d-9aee-c0f8dbc84c10
sigepi.autor.atividadeNASCIMENTO, G.G.:14794:330:S
sigepi.autor.atividadeCAMPOS, V.P.:753:330:N
sigepi.autor.atividadeCAMPOS, L.L.:1195:330:N
Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
30218.pdf
Tamanho:
843.85 KB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Coleções