Calibration of a clinical beta therapy applicator using the thermoluminescence samples

dc.contributor.authorLITVAC, DANIELpt_BR
dc.contributor.authorCALDAS, LINDA V.E.pt_BR
dc.coverageNacionalpt_BR
dc.creator.eventoCONGRESSO BRASILEIRO DE METROLOGIA, 10.; CONGRESSO INTERNACIONAL DE METROLOGIA ELÉTRICA, 13.; CONGRESSO INTERNACIONAL DE METROLOGIA MECÂNICA, 5.; CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIAÇÕES IONIZANTES, 6.; WORKSHOP DA REDE DE METROLOGIA QUÍMICA DO INMETRO, 4.; CONGRESSO BRASILEIRO DE METROLOGIA ÓPTICA, 3.pt_BR
dc.date.accessioned2020-03-30T13:47:03Z
dc.date.available2020-03-30T13:47:03Z
dc.date.evento24-27 de novembro, 2019pt_BR
dc.description.abstractIn some parts of Brazil, 90Sr/90Y clinical applicators are still used for dermatological and ophthalmic treatments, even with the higher efficiency of linear accelerators because they are of lower cost and easier use. Calibration and periodic recalibration of these applicators to verify the absorbed dose rate is essential to ensure accuracy in clinical treatments. In this work the thermoluminescent response of BeO and μLiF pellets was evaluated, determining the reproducibility, linearity of response and their dose-response curves. This standard, for this type of calibration, recommends the use of small detectors such as μLiF. Therefore, the utility of μLiF and BeO in the calibration of clinical applicators was compared.pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)pt_BR
dc.description.sponsorshipIDCNPq: 301335/2016-8pt_BR
dc.description.sponsorshipIDCAPES: 554/2018pt_BR
dc.identifier.citationLITVAC, DANIEL; CALDAS, LINDA V.E. Calibration of a clinical beta therapy applicator using the thermoluminescence samples: preliminary results. In: CONGRESSO BRASILEIRO DE METROLOGIA, 10.; CONGRESSO INTERNACIONAL DE METROLOGIA ELÉTRICA, 13.; CONGRESSO INTERNACIONAL DE METROLOGIA MECÂNICA, 5.; CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIAÇÕES IONIZANTES, 6.; WORKSHOP DA REDE DE METROLOGIA QUÍMICA DO INMETRO, 4.; CONGRESSO BRASILEIRO DE METROLOGIA ÓPTICA, 3., 24-27 de novembro, 2019, Florianópolis, SC. <b>Anais...</b> Rio de Janeiro, RJ: Sociedade Brasileira de Metrologia, 2019. Disponível em: http://repositorio.ipen.br/handle/123456789/30987.
dc.identifier.orcid0000-0002-7362-2455pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/30987
dc.localRio de Janeiro, RJpt_BR
dc.local.eventoFlorianópolis, SCpt_BR
dc.publisherSociedade Brasileira de Metrologiapt_BR
dc.rightsopenAccesspt_BR
dc.subjectberyllium oxides
dc.subjectlithium fluorides
dc.subjectbeta particles
dc.subjectcalibration
dc.subjectcomparative evaluations
dc.subjectdosimetry
dc.subjectradiation sources
dc.subjecttherapy
dc.subjectthermoluminescence
dc.titleCalibration of a clinical beta therapy applicator using the thermoluminescence samplespt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorDANIEL LITVAC
ipen.autorLINDA V. E. CALDAS
ipen.codigoautor14585
ipen.codigoautor1495
ipen.contributor.ipenauthorDANIEL LITVAC
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.date.recebimento20-03
ipen.event.datapadronizada2019pt_BR
ipen.identifier.ipendoc26784pt_BR
ipen.notas.internasAnaispt_BR
ipen.subtitulopreliminary resultspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublicationadb18c99-f219-46cb-a9d1-f852aed21453
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication.latestForDiscoveryadb18c99-f219-46cb-a9d1-f852aed21453
sigepi.autor.atividadeCALDAS, LINDA V.E.:1495:330:Npt_BR
sigepi.autor.atividadeLITVAC, DANIEL:14585:330:Spt_BR
Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
26784.pdf
Tamanho:
764.87 KB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Coleções