Comparative study of different Al2O3:C dosimeters using OSL technique for dosimetry on Volumetric Modulated Arc Radiotherapy Treatment (VMAT)
dc.contributor.author | VILLANI, DANIEL | |
dc.contributor.author | MANCINI, ANSELMO | |
dc.contributor.author | HADDAD, CECILIA M.K. | |
dc.contributor.author | CAMPOS, LETICIA L. | |
dc.coverage | Nacional | pt_BR |
dc.creator.evento | CONGRESSO BRASILEIRO DE FÍSICA MÉDICA, 21. | pt_BR |
dc.date.accessioned | 2017-05-10T12:45:48Z | |
dc.date.available | 2017-05-10T12:45:48Z | |
dc.date.evento | 24-27 de agosto, 2016 | pt_BR |
dc.description.abstract | In modern radiotherapy, the VMAT technique has become a successful treatment alternative. Due to its complexity, a quality assurance program must be established by evaluating, among other items, the dosimetric factors. This paper aims to compare the performance between the OSL aluminum oxide (Al2O3:C) nanoDot™ dosimeters (Inlight™ system) manufactured by Landauer Inc. and TLD-500 Al2O3:C dosimeters manufactured by Rexon™ for VMAT dosimetry using an anthropomorphic phantom. The results showed that both type of Al2O3:C dosimeters presented good repeatability and agreement between the doses measured and calculated by planning system. However, the need of sophisticated readers to OSL analysis of the TLD-500, turns it less practical for routine usage, comparing to Inlight™ system. Keywords: OSL dosimetry; VMAT; Al2O3:C. | pt_BR |
dc.event.sigla | ABFM | pt_BR |
dc.format.extent | 1-5 | pt_BR |
dc.identifier.citation | VILLANI, DANIEL; MANCINI, ANSELMO; HADDAD, CECILIA M.K.; CAMPOS, LETICIA L. Comparative study of different Al2O3:C dosimeters using OSL technique for dosimetry on Volumetric Modulated Arc Radiotherapy Treatment (VMAT). In: CONGRESSO BRASILEIRO DE FÍSICA MÉDICA, 21., 24-27 de agosto, 2016, Florianópolis, SC. <b>Proceedings...</b> p. 1-5. Disponível em: http://repositorio.ipen.br/handle/123456789/27432. | |
dc.identifier.orcid | https://orcid.org/0000-0001-7137-0613 | |
dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/27432 | |
dc.local.evento | Florianópolis, SC | pt_BR |
dc.rights | openAccess | pt_BR |
dc.title | Comparative study of different Al2O3:C dosimeters using OSL technique for dosimetry on Volumetric Modulated Arc Radiotherapy Treatment (VMAT) | pt_BR |
dc.title.alternative | Estudo comparativo de diferentes dosímetros de Al2O3:C pela técnica OSL na dosimetria de tratamentos Radioterápicos por Arco Modulado Volumétrico (VMAT) | pt_BR |
dc.type | Texto completo de evento | pt_BR |
dspace.entity.type | Publication | |
ipen.autor | LETICIA LUCENTE CAMPOS RODRIGUES | |
ipen.autor | DANIEL VILLANI | |
ipen.codigoautor | 1195 | |
ipen.codigoautor | 12762 | |
ipen.contributor.ipenauthor | LETICIA LUCENTE CAMPOS RODRIGUES | |
ipen.contributor.ipenauthor | DANIEL VILLANI | |
ipen.date.recebimento | 17-05 | pt_BR |
ipen.event.datapadronizada | 2016 | pt_BR |
ipen.identifier.ipendoc | 23731 | pt_BR |
ipen.notas.internas | Proceedings | pt_BR |
ipen.type.genre | Artigo | |
relation.isAuthorOfPublication | d4d34119-a6e6-4026-9a67-7b16d8b668da | |
relation.isAuthorOfPublication | 26698252-02e7-4d43-8ffb-edaf9f863fa2 | |
relation.isAuthorOfPublication.latestForDiscovery | 26698252-02e7-4d43-8ffb-edaf9f863fa2 | |
sigepi.autor.atividade | VILLANI, DANIEL:12762:330:S | pt_BR |
sigepi.autor.atividade | CAMPOS, LETICIA L.:1195:330:N | pt_BR |