Agora exibindo 1 - 6 de 6
  • Resumo IPEN-doc 26562
    Iridium-192 seed development for ophthalmic cancer treatment
    2011 - ROSTELATO, M.E.C.M.; MATTOS, F.R.; ZEITUNI, C.A.; SOUZA, C.D.; MOURA, J.A.; MOURA, E.S.; FEHER, A.; COSTA, O.L.; PELEIAS JUNIOR, F.S.; MARQUES, J.R.O.; BELFORT NETO, R.
    Considered a public health problem in Brazil, cancer is the second leading cause of mortality by disease, representing 13.2% of all deaths in the country [1]. Ophthalmic brachytherapy involves inserting an acrylic plate with radioactive material in the eyes of a patient for treatment of ocular tumors. This work is a partnership between Escola Paulista de Medicina - UNIFESP and the Instituto de Pesquisas Energéticas e Nucleares - IPEN for development and implementation of a cheaper therapeutic treatment for ophthalmic cancer with a iridium-192 source, to attend a greater number of patients. Iridium-192 is produced in nuclear reactor. It has a half-life of 74.2 days and decays by beta emission with average energy of 370 keV.[2,3]. The seed will be a platinum-iridium alloy core (80/20), encapsulated in a titanium tube [4]. This project will be divided into the following steps: characterization of materials by FRX (X-ray fluorescence) e EDS (Energy Dispersive Spectroscopy); iridium irradiation in the nuclear reactor IEA-R1; sealing of iridium-192 seed; leakage tests of iridium-192 source in accordance with standard ISO-9978 (radiation protection- Sealed radioactive sources- Leakage test methods) [5]; metallographic tests and measure the activity of the source. The evaluation for use in the ophthalmic treatment of cancer will be made later.
  • Artigo IPEN-doc 22887
    Surface coating and study of metallic cores for radioactive sources production used in cancer treatment
    2016 - ROSTELATO, M.E.C.M.; SOUZA, C.D.; ZEITUNI, C.A.; MATTOS, F.R.; MARQUES, J.R.O.; MOURA, J.A.; FEHER, A.; COSTA, O.L.; SOUZA, D.C.B.; TIEZZI, R.; RODRIGUES, B.T.; KARAM JUNIOR, D.
    Developing new and innovative treatments for cancer is an urgent matter. The National Institute of Cancer estimates that Brazil will have 576,000 new cases of the disease in 2015. Our research group is developing new radioactive seeds to be use in radiotherapy procedures since the early 2000’s. We present the surface study and research for two of our major projects: iodine-125 seeds for prostate, brain and eye cancer treatment and iridium-192 for eyecancer treatment.
  • Artigo IPEN-doc 19382
    Development of irradiation support devices for production of brachytherapy seeds
    2013 - MATTOS, FABIO R.; ROSTELATO, MARIA E.C.M.; ZEITUNI, CARLOS A.; SOUZA, CARLA D.; MOURA, JOAO A.; PELEIAS JUNIOR, FERNANDO S.; KARAN JUNIOR, DIB; FEHER, ANSELMO; OLIVEIRA, TIAGO B.; BENEGA, MARCOS A.G.
  • Artigo IPEN-doc 19425
    Influence of the profile of iridium-192 wire in measurements of quality control for use in brachytherapy
    2013 - COSTA, OSVALDO L.; ZEITUNI, CARLOS A.; ROSTELATO, MARIA E.C.M.; MOURA, JOAO A.; FEHER, ANSELMO; MOURA, EDUARDO S.; SOUZA, CARLA D.; SOMESSARI, SAMIR L.; PELEIAS JUNIOR, FERNANDO S.; MATTOS, FABIO R.
  • Artigo IPEN-doc 17184
    Development of an iridium-192 seed for use in ophthalmic brachytherapy
    2011 - MATTOS, FABIO R.; ROSTELATO, MARIA E.C.M.; ZEITUNI, CARLOS; MOURA, JOAO A.; COSTA, OSVALDO L.; FEHER, ANSELMO; MOURA, EDUARDO S.; SOUZA, CARLA D.; PELEIAS JUNIOR, FERNANDO S.
  • Dissertação IPEN-doc 19093
    Estudo e desenvolvimento de uma semente de irídio-192 para aplicação em câncer oftálmico
    2013 - MATTOS, FABIO R. de
    Mesmo não estando entre os casos de câncer com maior incidência, os tumores oculares têm acometido a população brasileira. O Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP), juntamente à Escola Paulista de Medicina (UNIFESP), criou um projeto que visa o desenvolvimento e implementação de um tratamento de câncer oftálmico alternativo que consiste na utilização de sementes de irídio-192 em braquiterapia. O Projeto surgiu pelo motivo da Escola Paulista tratar muitos casos oncológicos no âmbito do Sistema Único de Saúde (SUS) e pela experiência em pesquisas de fontes radioativas seladas do grupo de braquiterapia do IPEN. A metodologia foi desenvolvida a partir da infraestrutura disponível e pela experiência dos pesquisadores. O protótipo desenvolvido da semente se apresenta com um núcleo (irídio em liga de irídio-platina) de 3,0mm de comprimento selado por uma cápsula de titânio de 0,8mm de diâmetro externo, 0,05mm de espessura de parede e 4,5mm de comprimento. Nenhum estudo sobre a confecção destas sementes foi encontrado em literatura disponível. Criou-se uma metodologia que envolveu: caracterização do fio, criação do dispositivo para ativação neutrônica dos núcleos e testes de estanqueidade da fonte produzida. A análise dos resultados comprovaram a viabilidade do método. Como sugestão para trabalhos futuros, estudos quanto à metrologia e dosimetria destas fontes e aprimoramento da metodologia devem ser realizados, para uma futura implementação em caráter nacional.