PATRICIA DE ANDRADE MARTINS

Projetos de Pesquisa
Unidades Organizacionais
Cargo

Resultados de Busca

Agora exibindo 1 - 10 de 32
  • Artigo IPEN-doc 28221
    Evaluation of dithiol spectrophotometric method for tin determination in lyophilized reagents
    2021 - CASTRO, HIGOR R.G.; COURI, VICENZO S.F.; MARTINS, PATRICIA de A.; SANTOS, JOEL M. dos; MATSUDA, MARGARETH M.N.
  • Resumo IPEN-doc 27748
    Determinação de estanho total por ICP-OES em reagentes liofilizados
    2020 - SILVA, JOSE L. da; MARTINS, PATRICIA de A.; SANTOS, JOEL M. dos; SILVA, LAERCIO da; SILVA, NATANAEL G. da; FUKUMORI, NEUZA T.O.; MATSUDA, MARGARETH M.N.
    O tecnécio-99m (99mTc) é o radioisótopo mais utilizado na medicina nuclear para obtenção de imagens para diagnóstico por SPECT. Seu estado de oxidação pode variar de -1 a +7, quando reage com uma variedade de compostos na presença de Sn(II).O cloreto estanoso diidratado é o agente redutor do 99mTc mais utilizado na formulação de reagentes liofilizados(RL). A determinação quantitativa de estanho total e Sn(II) são controles importantes para o processo de fabricação a fim de garantir a qualidade durante o prazo de validade dos RL. O objetivo deste trabalho foi quantificar o Sn total nos RL MDP-TEC e MIBI-TEC (IPEN) usando ICP-OES como método alternativo ao método colorimétrico descrito nas farmacopeias. As massas quantificadas de cloreto estanoso nos RL analisados estiveram compreendidas entre 90-110 % em relação ao descrito na bula do radiofármaco. O método analítico proposto por ICP-OES mostrou-se excelente para determinação de Sn total.
  • Resumo IPEN-doc 27747
    Controle radionuclídico de radiofármacos de Lu-177
    2020 - MARTINS, PATRICIA de A.; SANTOS, JOEL M. dos; SILVA, JOSE L. da; SILVA, LAERCIO da; FUKUMORI, NEUZA T.O.; ARAUJO, ELAINE B. de; HIROMOTO, GORO; MATSUDA, MARGARETH M.N.
    O lutécio-177 (Lu-177) é um radioisótopo produzido em reator, com meia-vida física (t/) de 6,73 dias e decaimento por emissão beta de 498,3 keV e raios y energias de 208,37 keV e 112,9 keV, adequados para o tratamento de câncer de tumores neuroendócrinos e de próstata. A determinação da pureza radionuclídica de radiofármacos de lutécio-177 visa verificar se a porcentagem de radionuclídeos atendem aos critérios estabelecidos na Farmacopeia Europeia (FE). Este trabalho tem por objetivo estabelecer as condições para realizar o controle radionuclídico de DOT-IPEN-177 produzido no IPEN-CNEN/ SP. Os resultados de identificação e pureza radionuclídica de DOT-IPEN-177 encontrados foram satisfatórios pois atenderam aos critérios estabelecidos na FE.
  • Artigo IPEN-doc 26245
    Proposal of an identification test for MIBI-TEC® lyophilized reagent using infrared spectroscopy
    2019 - SANTOS, JOEL M. dos; FUKUMORI, NEUZA T.O.; OLIVEIRA, IDELI M. de; MARTINS, PATRICIA de A.; SILVA, NATANAEL G. da; MATSUDA, MARGARETH M.N.
    Quality Control is part of the Good Manufacturing Practices (GMP) responsible for the evaluation and release of pharmaceutical components, including active ingredients and excipients, to assure compliance with the specifications in pharmacopoeias. GMP for radiopharmaceuticals is regulated by RDC N. 17/2010 and RDC N. 63/2009 (ANVISA) establishing the minimum quality standards in industrial manufacture. Pharmacopoeias have the specifications for lyophilized reagents (LR) labeled with 99mTc regarding radiochemical purity, biodistribution and, in case of parenteral use, bacterial endotoxins and sterility tests must be performed. In radiopharmaceutical monographs, the necessity of non radioactivity assays for releasing lyophilized reagents are not well described, but ANVISA requires assays to assure the quality of the lyophilized powder, as active ingredient quantification and identification assays, stannous ion quantification and moisture determination. Infrared (IR) spectroscopy is widely used for identification of substances, mainly raw materials. The aim of this work is to propose an identification assay for MIBI-TEC® LR powder using IR spectroscopy. MIBI-TEC® batches were produced at IPEN/CNEN-SP and about 2 mg of the LR powder were mixed with 200 mg KBr, pressed at 80 kgf during 5 minutes into the holder to obtain a transparent pellet. The pellet was placed in ABB IR spectrometer, FTLA 2000 model, and a spectrum in the medium infrared region of 450 to 4000 cm-1 was acquired using Grams software. Tetramibi cuprous tetrafluoroborate, stannous chloride dihydrate, cysteine hydrochloride monohydrate, sodium citrate and mannitol had their respective IR spectrum recorded and the main characteristic absorptions were established for each formulation component. In the MIBI-TEC® spectrum, it was possible to observe a well characterized absorption in 2193 cm-1 which represents the presence of C≡N binding of tetramibi cuprous tetrafluoroborate active ingredient, free of interference, indicating that IR spectrum can be used as identification assay of the LR.
  • Artigo IPEN-doc 26239
    Dose calibrator and gamma counter
    2019 - SILVA, VITOR M.A. da; SOUSA, JURANDIR A. de; MARTINS, PATRICIA de A.; FUKUMORI, NEUZA T.O.; SILVA, NATANAEL G. da; MATSUDA, MARGARETH M.N.
    To ensure that pharmaceutical products have and maintain the structure, identity, purity, concentration, potency and safety characteristics required for their use, there is a set of standard procedures called Good Manufacturing Practices (GMP). In Brazil, the National Sanitary Surveillance Agency (ANVISA) regulates the GMP production of medicines through RDC17/2010 and for radiopharmaceuticals through RDC 63/2009 and 38/2008, to ensure their safe and correct use in commercial production and nuclear medicine services, respectively. Most 99mTc radiopharmaceutical monographs have biological distribution specifications. Using invasive method, 99mTcradiopharmaceuticalsare assessed by the injection into animals of defined strains and the radioactivity (as percentage of retainedor injected dose -%RDor%ID)ismeasured in specified organs. Technetium-99m Sestamibi radiopharmaceutical (99mTc-2-methoxy-isobutyl-isonitrile; 99mTc-sestamibi; MIBI-TEC®) monograph is related in USP 41, but the biological distribution assay is not included. At IPEN, the biodistribution test is performed as established in the Radiopharmaceutical Quality Control Manual of ARCAL XV (1999) - International Atomic Energy Agency (IAEA), for each batch. The objective of this work is to compare MIBI-TEC®biodistribution results using dose calibrator and gamma counter with sodium iodide detector by measuring the radioactivity in the organs. Three batches of MIBI-TEC®were used and 1 vial of lyophilized reagent (LR) was labeled with 5-10 mCiin 1-3 mL of 99mTc eluate. 200-300 μCi in 0.2 mLwereinjected in 3 Balb-Cmice. After 30 minutes of biodistribution, heart, lung, muscle, liver, paw, column and tail were withdrawn, weighed and radioactivity was measured in dose calibrator and gamma counter (μCi andcpm, respectively). %ID/g ratio in the organs of interest was calculated using the data obtained by both equipment and the results were compared. No significant differences were observed and it was possible to conclude that either a dose calibrator or a gamma counter can be used in the routine of quality control.
  • Artigo IPEN-doc 26238
    Radiochemical purity determination of technetium (99m)Tc-sestamibi by high performance liquid chromatography (HPLC)
    2019 - MARTINS, PATRICIA de A.; FUKUMORI, NEUZA T.O.; SILVA, NATANAEL G. da; MATSUDA, MARGARETH M.N.
    The assessment of the extent of reversible or irreversible mitochondrial damage after myocardial ischemia is performed by obtaining myocardial perfusion SPECT-CT images of Technetium-99m Sestamibi radiopharmaceutical (99mTc-2-methoxy-isobutyl-isonitrile; 99mTc-sestamibi; 99mTc-MIBI). For quality control purposes, the monograph of the United States Pharmacopoeia (USP) was followed. The determination of the radiochemical purity of 99mTc-sestamibi involves the use of two chromatographic methods: thin layer chromatography in reverse phase and high performance liquid chromatography. This work aims to determine the radiochemical purity of 99mTc-sestamibi by the HPLC method described in USP. The analyses were performed on a Shimadzu liquid chromatography, LC-20AT model, consisting of two pumps, degasser, automatic sample injector, UV-visible detector and Bioscan radioactivity detector. The column used was μBondapack C18 (3.9 x 300 mm, 10 μm, Waters) and the mobile phase was a mixture of acetonitrile, 0.05 mol L-1 ammonium sulfate and methanol (20:35:45). 5 μL of sample (approximately 250 μCi) was injected with a 2 mL min-1 mobile phase flow. According to the USP monograph, the retention time for 99mTc-sestamibi is 5-10 minutes and for the 99mTc-pentamibidimethylvinylisonitrile impurity is 6-13 minutes. Not less than 90% of the total radioactivity must be present as 99mTc-sestamibi and not more than 5% as 99mTc-pentamibidimethylvinylisonitrile. For 12 analyzed batches of MIBI-TEC® produced at IPEN/CNEN-SP, the product presented a retention time of 7 minutes and the 99mTc-pentamibidimethylvinylisonitrile impurity formation was not observed.
  • Resumo IPEN-doc 25549
    Adequação do ensaio de distribuição biológica de TIN-TEC à farmacopeia europeia
    2018 - MARTINS, P.A.; SOUSA, J.A.; ESTRELA, I.M.O.; SILVA, N.G.; FUKUMORI, N.T.O.; MATSUDA, M.M.N.
    Introdução – O ensaio de biodistribuição em animais de experimentação está especificado em monografias de alguns reagentes liofilizados (RL) marcados com tecnécio-99m nas farmacopeias e em guias da Agência Internacional de Energia Atômica (AIEA) para garantir a eficácia e a qualidade do produto. Uma vez que esse ensaio esteja descrito para um determinado radiofármaco, é mister que o fabricante o execute. O estanho coloidal (99m Tc) (TIN-TEC) é empregado em linfocintilografia, cintilografia gástrica e imagem do sistema retículoendotelial. Objetivo – Este trabalho avaliou a biodistribuição do TIN-TEC em camundongos, para adequação à farmacopeia europeia, em relação ao ensaio realizado no IPEN, o qual se baseava no guia da AIEA com a utilização de ratos da linhagem Wistar. Material e Métodos – Foram analisados 6 lotes de TIN-TEC em ratos Wistar (150-250 g) e camundongos Swiss (20-25 g). O ensaio foi realizado em 3 animais de cada linhagem, para cada lote. O RL foi marcado com 370 MBq (10 mCi) em 3 mL de solução de Na99mTcO4. Após 30 minutos de reação, administrou-se na veia caudal de cada um dos animais, uma dose de 7400 – 11100 MBq (200 – 300 μCi) em 0,2 mL. Após 20 minutos de biodistribuição, os animais foram eutanasiados com dose letal de anestésico e a radioatividade do fígado, baço, pulmão e carcaça (sem a cauda) foi medida em calibrador de doses (Ci), e o cálculo de % dose retida (% D.R.) em cada um dos órgãos foi efetuado. Resultados – Os Limites de Especificação descritos para estanho coloidal (99m Tc) na Farmacopeia Europeia 9.0 são: % D.R. Fígado+baço ≥ 80% e % D.R. Pulmão ≤ 5%. Todos os resultados de % D.R. nos órgãos de estudo encontraram-se de acordo com os limites em ambas as linhagens de animais. A % D.R. de Fígado+Baço situou-se entre 84,44 – 92,90 e 91,83 – 98,29, para camundongos e ratos, respectivamente, enquanto os resultados de % D.R. no pulmão foram similares e a % D.R. carcaça apresentou-se maior em camundongos. Discussão – A realização do ensaio de biodistribuição com resultados em conformidade com os requisitos descritos em compêndios oficiais assegura a distribuição fisiológica apropriada do radiofármaco no órgão alvo em humanos. Os resultados obtidos para o TIN-TEC em camundongos dentro dos limites de aceitação da monografia da farmacopeia europeia permitiram estabelecer a adequação aos critérios farmacopeicos. Conclusões – As diferentes linhagens de animais no ensaio de biodistribuição do TIN-TEC confirmaram a eficácia e a qualidade do produto.
  • Resumo IPEN-doc 23701
    A proposal for validation of the radiochemical purity of Technetium Tc99m Pentetate
    2015 - BENEDETTI, S.; PUGA, R.S.; MARTINS, P.A.; MENGATTI, J.; FUKUMORI, N.T.O.; MATSUDA, M.M.N.
  • Resumo IPEN-doc 21363
  • Resumo IPEN-doc 14333
    Evaluation of Weight influence on Tc-99m-MDP biodistribution in rats
    2009 - MARTINS, PATRICIA de A.; SILVA, NATANAEL G. da; FREIRE, ANTONIO C.; VICENTE, IRENE; FUKUMORI, NEUZA T.O.; BARBOZA, MARYCEL F. de; MATSUDA, MARGARETH M.N.; MURAMOTO, EMIKO