MAURO NORIAKI TAKEDA
23 resultados
Resultados de Busca
Agora exibindo 1 - 10 de 23
Resumo IPEN-doc 24574 Disintegration rate and gamma-ray emission probability per decay measurement of Cu-642017 - KOSKINAS, M.F.; YAMAZAKI, I.M.; MOREIRA, D.S.; TAKEDA, M.N.; DIAS, M.S.This work aims to present the 64Cu standardization method developed in the Nuclear Metrology Laboratory (LMN) at the IPEN-CNEN/SP, using a 4 coincidence system, and the measurement of the gamma-ray emission probabilities per decay of 1345.7 keV of 64Cu by means of a REGe gamma-ray spectrometer. The 4 coincidence system consists of a gas- flow proportional counter with 4 geometry and using 90% Ar + 10% CH4 gas at 0.1 MPa, as the detector, coupled to two NaI(Tl) crystal for the gamma-ray emission detection. The events were registered by means of a Time to Amplitude Converter (TAC) associated with a Multi-Channel Analyzer. Two gamma-ray windows were set for the coincidence measurements, one including the positron-annihilation quanta and the other located at the total absorption energy peak of the 1345.7 keV gamma-ray transition. The 64Cu was obtained by irradiating 0.3mg of metallic cooper in the IEA-R1 research reactor under a 1 1013 cm2 s1 thermal neutrons flux. To obtain the 64Cu solution the foil irradiated was dissolved in 20 L of HNO3 65% and after that was diluted in 20 mL of 0.1M HCl. The activity was determined by means of the extrapolation curve from eight irradiations, normalized by means of the germanium measurements. The Kawada factor to correct the inefficiency for beta plus and beta minus in the N4 has been applied. The gamma-ray full efficiency peak curve of the germanium spectrometer was measured at 17.9 cm of source-detector distance, in the energy range from 244 keV to 2754 keV, by measuring flamed-sealed ampoules of 24Na, 60Co, 133Ba, 137Cs, and 152Eu standardized at the LMN. The sample for measurement in the spectrometer was prepared in flame-sealed ampoule with 1 mL of the diluted solution. The gamma-ray emission probability per decay of the 1345.7 keV transition of 64 Cu was (0.472 0.010)%, in agreement with the literature.Artigo IPEN-doc 24232 Disintegration rate and gamma-ray emission probability per decay measurement of Cu-642018 - YAMAZAKI, I.M.; KOSKINAS, M.F.; MOREIRA, D.S.; TAKEDA, M.N.; DIAS, M.S.The procedure followed by the Nuclear Metrology Laboratory (LMN) at the IPEN for the standardization of activity of 64Cu is described. The measurement was carried out in a 4π (PC) β-γ coincidence system. The activity per unit mass of the solution was determined by the extrapolation technique. The events were registered using a Time to Amplitude Converter (TAC) associated with a Multi-channel Analyzer. The gamma-ray emission probability per decay of the 1345.7 keV transition of 64Cu determined with a calibrated REGe gamma-ray spectrometer was (0.472±0.010) %, in agreement with the literature.Artigo IPEN-doc 22595 Application of Monte Carlo simulation to 134Cs standardization by means of 4 ‘pi’’beta’-‘gamma’ coincidence system2005 - TAKEDA, MAURO N.; DIAS, MAURO da S.; KOSKINAS, MARINA F.Artigo IPEN-doc 22525 Disintegration rate and gamma ray probability per decay measurement of 166mHo2010 - MOREIRA, D.S.; KOSKINAS, M.F.; DIAS, M.S.; TAKEDA, M.N.Resumo IPEN-doc 09227 Monte Carlo simulation of activity measurements by means of 4 pi beta-gamma coincidence system2003 - TAKEDA, M.N.; DIAS, M.S.; KOSKINAS, M.F.Resumo IPEN-doc 15532 Monte Carlo simulation of 'beta-gamma' coincidence system using plastic scintillators in 4'pi' geometry2006 - DIAS, M.S.; PIUVEZAM FILHO, H.; BACCARELLI, A.M.; TAKEDA, M.N.; KOSKINAS, M.F.Resumo IPEN-doc 07865 Determinacao da correcao para o efeito de soma em cascata para espectrometros de HPGe e Ge(Li)2000 - TAKEDA, M.N.; DIAS, M.S.; KOSKINAS, M.F.Artigo IPEN-doc 10572 Tracing method applied to the standardization of sup(137)Gs2005 - KOSKINAS, M.F.; FERREIRA, C.R.P.P.; YAMAZAKI, I.M.; TAKEDA, M.N.; DIAS, M.S.Artigo IPEN-doc 10977 Application of Monte Carlo simulation to sup(134)Cs standardization by means of 4 pi-beta-gamma coincidence system2004 - TAKEDA, M.N.; DIAS, M.S.; KOSKINAS, M.F.Artigo IPEN-doc 19850 Standardization of sup(68)Ga by means of a 4'pi''beta'-'gamma' software coincidence system2012 - KOSKINAS, M.F.; LACERDA, F.W.; YAMAZAKI, I.M.; TOLEDO, F.; TAKEDA, M.N.; DIAS, M.S.
- «
- 1 (current)
- 2
- 3
- »