AUDREW FRIMAIO

Projetos de Pesquisa
Unidades Organizacionais
Cargo

Resultados de Busca

Agora exibindo 1 - 8 de 8
  • Artigo IPEN-doc 27199
    Comparative analysis of the transmission properties of tissue equivalent materials
    2020 - NASCIMENTO, BRUNA C.; FRIMAIO, AUDREW; BARRIO, RAMON M.M.; SIRICO, ANA C.A.; COSTA, PAULO R.
    Phantom objects have as main requirement to have the effective atomic number and linear attenuation coefficient approximately equal to the human tissue to be simulated. The present work aims to characterize samples of materials radiologically equivalent to water for dose studies in patients in the diagnostic energy range. Water was chosen as reference material representing human tissue, which is composed mostly of it. A set of samples was formulated and submitted to radiation transmission tests in four different values of tension applied to an Xray tube. Mass densities of the samples were evaluated using the Arquimedes method. The samples were identified as A, B, C and D. By transmission curves, it was possible to estimate the samples transmission factors corresponding to the water transmission factor for different thicknesses. Moreover, the thicknesses of samples equivalent to water thickness for different values of transmission factor were also evaluated. All the samples densities were bigger than the density of water. For the same thickness of water and the samples, the radiation transmission of the developed materials are in better agreement for thicknesses of 10mm and 30 mm. The lowest percentage difference between the water transmission and the transmission of any of the samples obtained was approximately 0.6% for the sample A in the thickness of 30mm under voltage of 60 kV. The correspondence between the transmission factors and the thicknesses showed that the compounds studied in this work are potential materials to develop phantoms that simulate the transmission properties of human tissue.
  • Tese IPEN-doc 26852
    Desenvolvimento de compostos termoplásticos ou termofixos radiologicamente equivalentes ao tecido humano
    2019 - FRIMAIO, AUDREW
    Os objetos simuladores constituídos de material tecido equivalente, são utilizados em laboratórios de pesquisa e em ambientes clínicos como parte de rotinas de controle de qualidade e radioproteção, são fundamentais para evitar a exposição de pessoas a doses de radiação. Os objetos simuladores são, na grande maioria, importados e de alto custo. Materiais radiologicamente equivalentes aos tecidos humanos, tem como principal requisito possuir o número atômico efetivo e/ou coeficiente de atenuação linear aproximadamente igual ao do tecido que se quer simular, de modo a reproduzir as suas características de atenuação à radiação ionizante incidente. Neste trabalho foram desenvolvidos compostos e protótipos que suprem a necessidade deste tipo de material radiologicamente equivalente a tecido utilizando tecnologia nacional. Os protótipos desenvolvidos e produzidos contêm substâncias, encontradas comercialmente, que, ao formarem um composto, seus percentuais são equivalentes aos encontrados no corpo humano, tais como tecido mamário, tecido mole, tecido adiposo e água A formulação dos compostos foi realizada por simulação computacional em trabalho realizado anteriormente, visando a produção de placas e/ou objetos (protótipos) com características de transmissão equivalentes ao de tecidos humanos e/ou à água. Os testes de desempenho dos protótipos produzidos apontaram as melhores formulações para aplicação em objetos simuladores na área de diagnóstico por imagem.
  • Resumo IPEN-doc 26040
    Comparative analysis of the transmission properties of radiologically equivalent materials
    2018 - NASCIMENTO, BRUNA C.; FRIMAIO, AUDREW; BARRIO, RAMON M.M.; SIRICO, ANA C.A.; COSTA, PAULO R.
  • Resumo IPEN-doc 26039
    X-ray spectrometry applied for determination of linear attenuation coefficient of tissue-equivalent materials
    2018 - FRIMAIO, AUDREW; NASCIMENTO, BRUNA C.; BARRIO, RAMON M.M.; CAMPOS, LETICIA L.; COSTA, PAULO R.
  • Artigo IPEN-doc 25850
    X-ray spectrometry applied for determination of linear attenuation coefficient of tissue-equivalent materials
    2019 - FRIMAIO, AUDREW; NASCIMENTO, BRUNA C.; BARRIO, RAMON M.M.; CAMPOS, LETICIA L.; COSTA, PAULO R.
    Resin-based materials equivalent to water were developed and four different samples were obtained. The linear attenuation coefficients of all samples was evaluated using X-ray spectrometry with primary and transmitted beams using voltages at the ranging from 60 to 120 kV. The experimental measured values were compared with theoretical reference values to water and with that obtained using the Least Square Method algorithm methodology (method applied to diagnostic radiology and radiotherapy). Our results show that differences between the measured values and the target μ(E) was lower than 7% ± 0.3 in the energy range from 20 to 80 keV. These results enable to consider that the material developed and produced is a good option to be used as a waterequivalent material and the experimental method adequate to its quantitative evaluation.
  • Resumo IPEN-doc 15396
    Desenvolvimento de materiais ceramicos para utilizacao em protecao radiologica diagnostica
    2006 - FRIMAIO, A.; COSTA, P.R.; VANDERLINDE, F.V.F.; CAMPOS, L.L.
  • Dissertação IPEN-doc 11345
    Desenvolvimento de um material cerâmico para utilização em proteção radiológica diagnóstica
    2006 - FRIMAIO, AUDREW
    Este estudo tem por objetivo formular um composto cerâmico para revestimento de paredes visando contribuir para a otimização da blindagem de salas de diagnóstico. O trabalho foi baseado em medidas experimentais de atenuação da radiação X (80 e 100 kV) empregando materiais cerâmicos de revestimento contendo diferentes suportes cerâmicos (vermelho, branco, grês, porcelanatos, etc). Dentre os suportes cerâmicos avaliados, o grês branco apresentou melhores propriedades atenuadoras, e foi considerado o mais adequado para a proposta deste trabalho. Diferentes formulações de grês branco foram estudadas e alteradas a fim de obter melhores propriedades atenuadoras. Foram efetuadas simulações de composições cerâmicas de revestimento grês dentro das porcentagens de matérias-primas necessárias na composição que são 12-20% argila; 6-18% caulim; 12-25% filito; 8-14% quartzo; 10-18% feldspato; 32- 40% pegmatito; 6-8% talco. As composições químicas quantitativas e qualitativas destes materiais foram também avaliadas, e os elementos constituintes mais comuns são SiO2, Fe2O3, Al2O3, CaO e Ti2O3. Considerando que o CaO pode ser substituído pelo PbO ou BaO, foram estudadas formulações com maiores teores de óxidos de Pb e Ba. O comportamento destes materiais como atenuadores para a radiação X foi investigado por meio de simulações computacionais que levaram em consideração os espectros de raios X incidentes e transmitidos através das diferentes composições estudadas e comparado com os materiais de referência Pb, Ba e BaSO4 (barita). Os resultados obtidos nas simulações indicaram as formulações do composto de suporte cerâmico grês que demonstram melhores propriedades de atenuação levando-se em conta as energias usadas em raios X diagnóstico (80, 100 e 150 kV). Placas cerâmicas baseadas na composição formulada que apresentou menor diferença percentual em relação ao Pb foram produzidas em laboratório e testadas fisicamente como revestimento de parede e barreira protetora. Propriedades como módulo de resistência à flexão, densidade, carga de ruptura, absorção de água e atenuação da radiação X foram avaliadas para todas as placas produzidas.
  • Artigo IPEN-doc 11798
    Development of a ceramic compound for coating the walls of image diagnosis centers for dose reduction of the medical team
    2006 - FRIMAIO, AUDREW; COSTA, PAULO R.; VANDERLINDE, FLAVIA V.F.; CAMPOS, LETICIA L.