JOSÉ QUINTO JUNIOR
12 resultados
Resultados de Busca
Agora exibindo 1 - 10 de 12
Artigo IPEN-doc 23190 Evaluation of intra root canal Er,Cr:YSGG laser irradiation on prosthetic post adherence2019 - QUINTO JUNIOR, JOSE; AMARAL, MARCELLO M.; FRANCCI, CARLOS E.; ANA, PATRICIA A.; MORITZ, ANDREAS; ZEZELL, DENISE M.Purpose: In clinical prosthetics procedures, including endodontics and post fixation, the presence of a smear layer can reduce the post bond strength. An Er,Cr:YSGG laser, which emits at 2780 nm, can promote a smear-layer-free surface due to the ablation process. Considering these aspects, the purpose of this work was to evaluate the influence of Er,Cr:YSGG laser irradiation using either a radial or an axial fiber tip on the bond strength of three resin cements to the fiber-reinforced composite posts. Materials and Methods: Ninety recently extracted single rooted human teeth had their root canal instrumented and were randomly distributed into nine experimental groups, in which three resin cements (total-etching Variolink II, self-etching Panavia F, and self-adhesive RelyX Unicem Aplicap) and three root canal treatments (no treatment, laser irradiation using the radial fiber tip, laser irradiation using the axial fiber tip) were used. Specimens were then sectioned into three sections (cervical, middle, and apical thirds) with two slices on each section. A push-out test was performed on each slice, and the values were recorded as MPa. The push-out data were analyzed by a Ryan-Joiner normality test followed by a two-way ANOVA test and Tukey pairwise comparison. The statistical analysis was performed on each third section separately, with a 5% significance level. Results: Laser irradiation with axial fiber tip significantly increased the post bond strength of RelyX Unicem Aplicap on middle third of specimens (p < 0.001) when compared to other root canal treatments (unlased or irradiated with radial tip). Considering the Panavia resin cement, laser irradiation with either axial or radial tips promoted a significant increase on the post bond strength of middle third when compared to unlased specimens (p < 0.001); however, laser irradiation did not influence the post bond strength of Variolink resin cement. Conclusions: The use of the Er,Cr:YSGG laser for clinical prosthetics procedures enhances the post bond strength of Panavia and RelyX Unicem Aplicap resin cements, mainly at middle third of roots, and does not interfere with the bond strength of Variolink resin cement. For the RelyX Unicem Aplicap system, the use of axial tip is most advantageous and can be recommended for future clinical application.Artigo IPEN-doc 24864 Effect of 830 nm diode laser irradiation of root canal on bond strength of metal and fiber post2018 - STREFEZZA, CLAUDIA; AMARAL, MARCELLO M.; QUINTO JUNIOR, JOSE; GOUW-SOARES, SHEILA C.; ZAMATARO, CLAUDIA B.; ZEZELL, DENISE M.Objective and background: The correct selections of the cementing agent, the endodontic post material and placement protocol are critical to provide an increased longevity of the teeth that went through endodontic treatment. The irradiation with diode laser before post cementation, can promote an antimicrobial effect. However, there is a lack of information about the effect of 830 nm diode laser on the post bond strength. This study analyzed the effect of dentin root canal irradiation with high-intensity diode laser, at 830 nm, operating in continuous or pulsed mode, on the retention of metal or fiber posts, cemented with self-etching resinous composite (Panavia F) and zinc phosphate cement (ZnPO4). Materials and methods: Human roots were irradiated with diode laser (continuous and pulsed mode). The fiber posts were luted with Panavia F and the metal posts with Panavia F or ZnPO4 cement. Specimens were sectioned into three sections (cervical, middle, and apical). The bond strength was measured by a push-out mechanical analysis. For the statistical analysis, a three-way ANOVA test was applied following a Tukey's pairwise comparison with a significance level of p = 0.05. Results: The irradiated groups presented higher bond strength compared with nonirradiated group (p < 0.05), and the cervical and middle thirds presented higher on bond strength than the apical. The association of metal post and Panavia F presented higher bond strength when irradiated on continuous mode (p < 0.05). Fiber post and Panavia F presented higher bond strength associated to pulsed mode. The mode seems not to make a significant difference. Conclusions: These results corroborate the importance of the post bond to dentin and root canal debris removal to increase the tooth longevity. It was shown that the dentin to post bond strength were enhanced by the diode laser irradiation either on continuous or pulsed modes.Artigo IPEN-doc 20860 Optical properties of human radicular dentin: ATR-FTIR characterization and dentine tubule direction influence on radicular post adhesion2015 - QUINTO JUNIOR, JOSE; ZAMATARO, CLAUDIA B.; BENETTI, CAROLINA; DIAS, DERLY A.; BLAY, ALBERTO; ZEZELL, DENISE M.Resumo IPEN-doc 14701 Chemical effects of Er, Cr:YSGG laser irradiation on intracanal dentin and the influence to tubules orientation2009 - QUINTO JUNIOR, J.; ANA, P.A.; ALBERTO, F.G.; ZEZELL, D.M.Resumo IPEN-doc 16035 FTIR spectroscopy monitoring chemical changes in enamel dentin and bone due to laser irradiation2010 - ZEZELL, DENISE M.; ANA, PATRICIA A.; BENETTI, CAROLINA; QUINTO JUNIOR, JOSE; PEREIRA, THIAGO M.; GOULART, VIVIANEResumo IPEN-doc 08045 Morphological and thermal analysis of resolidified dental enamel surface after dye assisted irradiation with A960nm diode laser2001 - QUINTO JUNIOR, J.; OLIVEIRA, M.V.; WETTER, N.U.; RATTICHIERI, F.; ZEZELL, D.M.; EDUARDO, C.P.Resumo IPEN-doc 18567 Influence of Er,Cr:YSGG irradiation in prosthatic post space in adhesion of fiber posts cemented with self-etching, total-etching or self adhesive2012 - ZEZELL, D.M.; QUINTO JUNIOR, J.Resumo IPEN-doc 19170 Tese IPEN-doc 17717 Lasers de Er,Cr:YSGG em condutos radiculares preparados para a cimentação de núcleos protéticos2011 - QUINTO JUNIOR, JOSEO objetivo deste estudo é avaliar a influência da irradiação com laser de Er,Cr:YSGG no espaço protético de condutos radiculares preparados para a fixação de pinos em fibra de vidro reforçados (FRC Postec®), avaliando-se o comportamento de três diferentes técnicas adesivas (self-etching= Panavia F®; total-etching= Excite DSC® + Variolink II® e self-adhesive= RelyX Unicem Aplicap®). Observaram-se as orientações da norma ISO-TS 11405 para a preparação das raízes dentais unirradiculares humanas. As amostras foram separadas na altura da junção amelo-dentinaria, tratadas endodonticamente com instrumentação rotatória e seladas com técnica de condensação lateral. Foram utilizados dois tipos diferentes de pontas de safira para irradiação intracanal o axial (Z4, 400 m de diâmetro) e o radial ou side firing (RFT4, 415 m de diâmetro) com densidade de energia de 40 J/cm2. Esta densidade de energia foi obtida como parte deste experimento, analisando-se diversos parâmetros de energia com os resultados morfológicos e térmicos obtidos. Nesta densidade, obtive-se grande quantidade de túbulos dentinários abertos e variação de temperatura segura para uso clínico. Cada raiz foi irradiada em cinco movimentos circulares, de apical para cervical, com intervalo de 20 segundos, entre elas. Os FRC Postec foram cimentados imediatamente após a irradiação e divididos randomicamente em nove grupos (n=10). Cada raiz foi seccionada em 6 discos de 1 mm de espessura para ensaio do tipo push-out, para a obtenção da força máxima de ruptura, e posterior cálculo da resistência de união adesiva em função da área de superfície do núcleo deslocado, resultando na pressão em MPa. A resistência de união adesiva nos grupos irradiados foi estatisticamente superior do que os grupos controle. Foram avaliadas as diferenças na resistência de união adesiva em diferentes porções do núcleo (cervical, médio e apical), onde o sistema adesivo tipo self-adhesive (RelyX Unicem Aplicap) teve o melhor resultado para os grupos irradiados. Avaliou-se por técnica de FTIR as diferenças químicas ocorridas na dentina intrarradicular irradiada com laser de Er,Cr:YSGG, em diferentes porções (cervical, médio e apical) em função da orientação dos túbulos. Foram observadas nos espectros de FTIR alterações na intensidade das bandas de algumas moléculas, indicando variação na quantidade da parte orgânica (amida I e amida II) após a irradiação, nas diferentes regiões dentais em função do feixe laser sobre a orientação dos túbulos dentinários, sem causar alterações na sua composição. Essas diferenças podem interferir no resultado da resistência de união adesiva. A técnica de utilização de laser de Er,Cr: YSGG em dentina radicular pré-cimentação de núcleo protético aumenta a resistência de união adesiva, na dependência do cimento utilizado.