In vitro flexural strength evaluation of a mini-implant prototype designed for Herbst appliance anchorage

Carregando...
Imagem de Miniatura
Data
2010
Data de publicação:
Orientador
Título da Revista
ISSN da Revista
Título do Volume
É parte de
É parte de
É parte de
Dental Press Journal of Orthodontics
Exportar
Mendeley
Projetos de Pesquisa
Unidades Organizacionais
Fascículo
Resumo
Aim: The purpose of this study was to evaluate the limit of flexural strength of a miniimplant prototype designed for Herbst appliance anchorage. Methods: After sample size calculation, four specimens with the new mini-implant were submitted to a single cantilever flexure test using a universal testing machine. The limit of flexural force strength was calculated. Results: The mini-implant prototype showed a limit of flexural force strength of 98.2 kgf (982 N), that was the lowest value found. Conclusion: The mini-implant prototype designed for Herbst appliance anchorage can withstand flexural forces higher than the maximum human bite forces reported in the literature.

Como referenciar
BARRETO-LOPES, KLAUS; DOMINGUEZ, GLADYS C.; TORTAMANO, ANDRE; ROSSI, JESUALDO L.; VIGORITO, JULIO W. In vitro flexural strength evaluation of a mini-implant prototype designed for Herbst appliance anchorage. Dental Press Journal of Orthodontics, v. 15, n. 4, p. 38.e1-38.e6, 2010. DOI: 10.1590/S2176-94512010000400006. Disponível em: http://repositorio.ipen.br/handle/123456789/26777. Acesso em: 26 Apr 2024.