Analysis of the tensile strength of straight and angled abutments in narrow diameter implants
Carregando...
Data
Data de publicação:
2018
Orientador
Título da Revista
ISSN da Revista
Título do Volume
É parte de
É parte de
É parte de
É parte de
CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.
Resumo
Despite the success of osseointegrated implants, some biomechanical problems, such
as loosening or fracture of the abutment, crown fixation screw loosening and prosthetic
instability, are common problems reported in the literature. Thus, the objective of the
present study was to analyse the tensile strength of straight and angled abutments in
narrow diameter implants installed by means of friction. The specimen was composed
of an implant of 3.3x11mm fixed 2 mm above of a resin block. The abutments were
fixed by friction receiving 3, 5 and 7 beats along the implant axis, and were positioned
with 0, 10 and 20 degrees of angulation. The abutments were subjected to tensile
force, totalizing 10 repetitions for each test. The results showed higher values of
removal strength for the abutments with 7 beats, and no statistical difference with 5
beats suggesting better mechanical stability.
Como referenciar
MICELLI, A.L.; MUCSI, C.S.; ROSSI, J.L.; ARANHA, L.C.; ALENCAR, M.C.; BOTTREL, J.; ANGELO, M.B.; ZAGNI, R.F.; RANGEL, E.T.; NIGRO, F. Analysis of the tensile strength of straight and angled abutments in narrow diameter implants. In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23., 04-08 de novembro, 2018, Foz do Iguaçu, PR. Resumo... p. 3885-3885. Disponível em: http://repositorio.ipen.br/handle/123456789/29532. Acesso em: 26 Apr 2024.