Stability and influence of dose rate in the signal response of the alamine gel dosimeter

dc.contributor.authorSILVA, CLEBER F.pt_BR
dc.contributor.authorCAMPOS, LETICIA L.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL CONFERENCE ON DEFECTS IN INSULATING MATERIALS, 16thpt_BR
dc.creator.eventoNTERNATIONAL CONFERENCE ON DEFECTS IN INSULATING MATERIALS, 16th
dc.date.accessioned2014-11-17T18:03:10Zpt_BR
dc.date.accessioned2014-11-18T18:17:08Zpt_BR
dc.date.accessioned2015-04-02T05:58:57Z
dc.date.available2014-11-17T18:03:10Zpt_BR
dc.date.available2014-11-18T18:17:08Zpt_BR
dc.date.available2015-04-02T05:58:57Z
dc.date.eventoAugust 24-29, 2008pt_BR
dc.date.evento2008
dc.description.abstractNowadays, the three dimensional (3D) dosimetry has been studied by many researchers for application in radiotherapy and radiosurgery treatments, because this kind of dosimeter enable to evaluate the 3D dose distribution. The alanine gel dosimeter was developed at IPEN to be applied to 3D dose evaluations using magnetic resonance imaging. This dosimeter is a gel material based on the transformation of the ferrous ions in ferric ions, which presents significant improvement on previous alanine systems developed by Costa (1994). The DL-Alanine (C3H7NO2) is an amino acid tissue equivalent that improves the production of ferric ions in the solution. The ferric ions concentration can be measured by spectrophometry technique. This work aims to analyse the stability and influence of the dose rate in the optical signal response of alanine gel dosimeter, since these two properties are very important for characterization and standardization of any dosimeter.
dc.event.siglaICDIM 2008pt_BR
dc.identifier.citationSILVA, CLEBER F.; CAMPOS, LETICIA L. Stability and influence of dose rate in the signal response of the alamine gel dosimeter. In: INTERNATIONAL CONFERENCE ON DEFECTS IN INSULATING MATERIALS, 16th, August 24-29, 2008, Aracaju, SE. <b>Proceedings...</b> Disponível em: http://repositorio.ipen.br/handle/123456789/15971.
dc.identifier.orcidhttps://orcid.org/0000-0001-7137-0613
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/15971pt_BR
dc.local.eventoAracaju, SEpt_BR
dc.rightsclosedAccesspt_BR
dc.sourcePublicado em: Journal of Physics: Conference Series, v. 249, n. 1, p. 012021-012026, 2010
dc.subjectalaninespt_BR
dc.subjectchemical dosemeterspt_BR
dc.subjectgelspt_BR
dc.subjectradiation dosespt_BR
dc.subjectdose ratemeterspt_BR
dc.subjectthree-dimensional calculationspt_BR
dc.subjectspectrophotometrypt_BR
dc.subjectelectron spin resonancept_BR
dc.subjectsignalspt_BR
dc.subjectspectral responsept_BR
dc.titleStability and influence of dose rate in the signal response of the alamine gel dosimeterpt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.autorCLÉBER FEIJÓ SILVA
ipen.codigoautor1195
ipen.codigoautor6547
ipen.contributor.ipenauthorLETICIA LUCENTE CAMPOS RODRIGUES
ipen.contributor.ipenauthorCLÉBER FEIJÓ SILVA
ipen.date.recebimento09-03pt_BR
ipen.event.datapadronizada2008pt_BR
ipen.identifier.ipendoc13425pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublicationd4d34119-a6e6-4026-9a67-7b16d8b668da
relation.isAuthorOfPublication19351730-db8a-40c9-9f2d-fa4f499a8a37
relation.isAuthorOfPublication.latestForDiscovery19351730-db8a-40c9-9f2d-fa4f499a8a37
sigepi.autor.atividadeSILVA, CLEBER F.:6547:330:Spt_BR
sigepi.autor.atividadeCAMPOS, LETICIA L.:1195:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
13425.pdf
Tamanho:
391.69 KB
Formato:
Adobe Portable Document Format
Descrição:

Coleções