Dose-rate constant and air-kerma strength evaluation of a new 125-I brachytherapy source using Monte-Carlo
dc.contributor.author | PRIMO, CAMILA de O. | pt_BR |
dc.contributor.author | ANGELOCCI, LUCAS V. | pt_BR |
dc.contributor.author | KARAM JUNIOR, DIB | pt_BR |
dc.contributor.author | ZEITUNI, CARLOS A. | pt_BR |
dc.contributor.author | ROSTELATO, MARIA E.C.M. | pt_BR |
dc.coverage | Internacional | pt_BR |
dc.creator.evento | INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE | pt_BR |
dc.date.accessioned | 2019-11-27T13:30:15Z | |
dc.date.available | 2019-11-27T13:30:15Z | |
dc.date.evento | October 21-25, 2019 | pt_BR |
dc.description.abstract | Brachytherapy is a modality of radiotherapy which treats tumors using ionizing radiation with sources located close to the tumor. The sources can be produced from several radionuclides in various formats, such as Iodine-125 seeds and Iridium-192 wires. In order to produce a new Iodine-125 seed in IPEN/CNEN and ensure its quality, it is essential to describe the dosimetry of the seed, so when applied in a treatment the lowest possible dose to neighboring healthy tissues can be reached. The report by the AAPM’s Task Group 43 U1 is a document that indicates the dosimetry procedures in brachytherapy based on physical and geometrical parameters. In this study, dose-rate constant and air-kerma strength parameters were simulated using the Monte Carlo method radiation transport code MCNP4C. The air-kerma strength is obtained from an ideal modeled seed, since its actual value should be measured for seeds individually in a specialized lab with a Wide-Angle Free-Air Chamber (WAFAC). Dose-rate constant and air-kerma strength are parameters that depends on intrinsic characteristics of the source, i.e. geometry, radionuclide, encapsulation, and together they define the dose-rate to the reference point, defined as the dose-rate to a point 1 cm away from the geometric center of the source, in its transverse plane. This study presents the values found for these parameters with associated statistical uncertainty, and is part of a larger project that aims the full dosimetry of this new seed model, including experimental measures. | pt_BR |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
dc.description.sponsorshipID | CAPES: 001 | |
dc.event.sigla | INAC | pt_BR |
dc.format.extent | 167-174 | pt_BR |
dc.identifier.citation | PRIMO, CAMILA de O.; ANGELOCCI, LUCAS V.; KARAM JUNIOR, DIB; ZEITUNI, CARLOS A.; ROSTELATO, MARIA E.C.M. Dose-rate constant and air-kerma strength evaluation of a new 125-I brachytherapy source using Monte-Carlo. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. <b>Proceedings...</b> Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 167-174. Disponível em: http://repositorio.ipen.br/handle/123456789/30344. | |
dc.identifier.orcid | 0000-0003-2943-6097 | pt_BR |
dc.identifier.orcid | 0000-0002-7303-6720 | pt_BR |
dc.identifier.orcid | https://orcid.org/0000-0003-2943-6097 | |
dc.identifier.orcid | https://orcid.org/0000-0002-7303-6720 | |
dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/30344 | |
dc.local | Rio de Janeiro | pt_BR |
dc.local.evento | Santos, SP | pt_BR |
dc.publisher | Associação Brasileira de Energia Nuclear | |
dc.rights | openAccess | pt_BR |
dc.subject | brachytherapy | |
dc.subject | computerized simulation | |
dc.subject | dose rates | |
dc.subject | dosimetry | |
dc.subject | iodine 125 | |
dc.subject | kerma | |
dc.subject | monte carlo method | |
dc.title | Dose-rate constant and air-kerma strength evaluation of a new 125-I brachytherapy source using Monte-Carlo | pt_BR |
dc.type | Texto completo de evento | pt_BR |
dspace.entity.type | Publication | |
ipen.autor | LUCAS VERDI ANGELOCCI | |
ipen.autor | MARIA ELISA CHUERY MARTINS ROSTELATO | |
ipen.autor | CARLOS ALBERTO ZEITUNI | |
ipen.autor | CAMILA DE OLIVEIRA PRIMO | |
ipen.codigoautor | 12698 | |
ipen.codigoautor | 7 | |
ipen.codigoautor | 944 | |
ipen.codigoautor | 14989 | |
ipen.contributor.ipenauthor | LUCAS VERDI ANGELOCCI | |
ipen.contributor.ipenauthor | MARIA ELISA CHUERY MARTINS ROSTELATO | |
ipen.contributor.ipenauthor | CARLOS ALBERTO ZEITUNI | |
ipen.contributor.ipenauthor | CAMILA DE OLIVEIRA PRIMO | |
ipen.date.recebimento | 19-11 | |
ipen.event.datapadronizada | 2019 | pt_BR |
ipen.identifier.ipendoc | 26132 | pt_BR |
ipen.notas.internas | Proceedings | |
ipen.type.genre | Artigo | |
relation.isAuthorOfPublication | 34f99ea4-8545-4c90-80e2-e9fda638cd8c | |
relation.isAuthorOfPublication | da77b491-04ff-4c68-aa65-dead9208a48c | |
relation.isAuthorOfPublication | 02421b96-adef-4759-b25e-67d4759aa676 | |
relation.isAuthorOfPublication | a548b7e2-662a-4281-9e07-77e362e7b148 | |
relation.isAuthorOfPublication.latestForDiscovery | a548b7e2-662a-4281-9e07-77e362e7b148 | |
sigepi.autor.atividade | ROSTELATO, MARIA E.C.M.:7:230:N | pt_BR |
sigepi.autor.atividade | ZEITUNI, CARLOS A.:944:230:N | pt_BR |
sigepi.autor.atividade | ANGELOCCI, LUCAS V.:12698:230:N | pt_BR |
sigepi.autor.atividade | PRIMO, CAMILA de O.:14989:-1:S | pt_BR |