dc.description.abstractThis work continues the study initiated in 2003 of the PTW 77335 ionization chamber, showing their performance and functionality to be used as transmission chamber. Those chambers have the same characteristic of monitor chamber. They are flat kind with 112cm3 of volume, graphite window with thickness of 170µm and polarizing voltage of 100V. The chambers were named A and B, and they were connected to an electrometer Unidos also of PTW, and a 14C as a check source. The repeatibility test consists in 10 measurements in fix and repeated conditions. This test shows the behaviour of the ionization chamber in short time. To verify their long time stability, this test was made for 6 months. The results showed a good performance of the chamber model 77335 to be used as transmission chamber, as published before. The stability test showed that the chamber A (s. 1870) had a variation of 0.16 % and the chamber B (s.1868) 0.20%. The long time measurements showed a variation of +/- 1.8 % for chamber A and +/-1.6 for chamber B. The values showed the functionality of the chamber to be used as transmission chamber. The results showed good performance of the studied chambers, therefore, the continuing evaluation is needed to guarantee the quality of the results showed until now.
dc.event.siglaIRPA12pt_BR
dc.identifier.citationMIRANDA, JUREMA A.; POTIENS, MARIA da P.A. Evaluation of the utilization of flat ionization chamber as monitor chamber. In: INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 12th, October 19-24, 2008, Buenos Aires, Argentina. <b>Proceedings...</b> Disponível em: http://repositorio.ipen.br/handle/123456789/15924.
dc.identifier.orcidhttps://orcid.org/0000-0002-4049-6720
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/15924pt_BR
dc.local.eventoBuenos Aires, Argentinapt_BR
dc.rightsopenAccesspt_BR
dc.subjectdosimetrypt_BR
dc.subjectradiologypt_BR
dc.subjectdiagnostic techniquespt_BR
dc.subjectquality assurancept_BR
dc.titleEvaluation of the utilization of flat ionization chamber as monitor chamberpt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.autorJUREMA APARECIDA DE MIRANDA
ipen.codigoautor346
ipen.codigoautor2930
ipen.contributor.ipenauthorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.contributor.ipenauthorJUREMA APARECIDA DE MIRANDA
ipen.date.recebimento09-03pt_BR
ipen.event.datapadronizada2008pt_BR
ipen.identifier.ipendoc13375pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication30f213ae-321d-4d51-8763-0a2585255fb9
relation.isAuthorOfPublication6abe6642-3879-48e8-9db4-ca2945114b6a
relation.isAuthorOfPublication.latestForDiscovery30f213ae-321d-4d51-8763-0a2585255fb9
sigepi.autor.atividadeMIRANDA, JUREMA A.:-1:-1:Spt_BR
sigepi.autor.atividadePOTIENS, MARIA da P.A.:346:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
13375.pdf
Tamanho:
1.76 MB
Formato:
Adobe Portable Document Format

Coleções