Preliminary measurements to the establishment of a quality control programme for the activimeter calibration reference system

dc.contributor.authorMARTINS, ELAINE W.pt_BR
dc.contributor.authorPOTIENS, MARIA da P.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1stpt_BR
dc.date.accessioned2014-11-17T17:07:16Zpt_BR
dc.date.accessioned2014-11-18T18:21:43Zpt_BR
dc.date.accessioned2015-04-01T21:28:31Z
dc.date.available2014-11-17T17:07:16Zpt_BR
dc.date.available2014-11-18T18:21:43Zpt_BR
dc.date.available2015-04-01T21:28:31Z
dc.date.eventoSeptember 27 - October 2, 2009pt_BR
dc.description.abstractThe nuclear medicine techniques efficiency and safety depends on, beside other factors, a quality control programme, mainly regards to the nuclides activimeter utilization. The Calibration Laboratory of IPEN uses as a work standard, a tertiary standard system Capintec, calibrated at the Accredited Dosimetry Calibration Laboratory of the Medical Radiation Research Center – University of Wisconsin. In this work, as preliminary measurements to establish a quality control programme for the activimeter calibration procedures, initially the repeatability and reproducibility (long term stability) tests were performed using a sealed check source of 133Ba. Later on, to complete this quality control programme other check sources (137Cs, 57Co, 60Co) will be used to perform the same tests. A series of 80 experiments of 10 measurements each has been carried out. The reference system showed a good behaviour to the repeatability test, considering the tolerance limits of 5%. The percent deviations of all tested sources in the activity measurements were lower 1% to 133Ba.
dc.event.siglaINAC; ENAN; ENFIR; ENINpt_BR
dc.identifier.citationMARTINS, ELAINE W.; POTIENS, MARIA da P. Preliminary measurements to the establishment of a quality control programme for the activimeter calibration reference system. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. <b>Proceedings...</b> Disponível em: http://repositorio.ipen.br/handle/123456789/12266.
dc.identifier.orcidhttps://orcid.org/0000-0002-4049-6720
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/12266pt_BR
dc.local.eventoRio de Janeiro, RJpt_BR
dc.publisherSao Paulo: ABEN, 2009pt_BR
dc.rightsopenAccesspt_BR
dc.subjectbarium 133pt_BR
dc.subjectcalibrationpt_BR
dc.subjectcesium 137pt_BR
dc.subjectcobalt 57pt_BR
dc.subjectcobalt 60pt_BR
dc.subjectexperimental datapt_BR
dc.subjectoccupational exposurept_BR
dc.subjectquality controlpt_BR
dc.subjectradiation protectionpt_BR
dc.subjectstabilitypt_BR
dc.titlePreliminary measurements to the establishment of a quality control programme for the activimeter calibration reference systempt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.autorELAINE WIRNEY MARTINS
ipen.codigoautor346
ipen.codigoautor5968
ipen.contributor.ipenauthorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.contributor.ipenauthorELAINE WIRNEY MARTINS
ipen.date.recebimento09-10pt_BR
ipen.event.datapadronizada2009pt_BR
ipen.identifier.ipendoc15018pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication30f213ae-321d-4d51-8763-0a2585255fb9
relation.isAuthorOfPublicationa0291c92-b89b-4010-87cb-a17fe0b08289
relation.isAuthorOfPublication.latestForDiscoverya0291c92-b89b-4010-87cb-a17fe0b08289
sigepi.autor.atividadeMARTINS, ELAINE W.:5968:330:Spt_BR
sigepi.autor.atividadePOTIENS, MARIA da P.:346:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
15018.pdf
Tamanho:
93.09 KB
Formato:
Adobe Portable Document Format

Coleções