Calibration methodology and selection of TLD – 100

dc.contributor.authorLUCCA, LUIZA V.G. dept_BR
dc.contributor.authorRODRIGUES, BRUNA T.pt_BR
dc.contributor.authorSOUZA, PAULO R.D. dept_BR
dc.contributor.authorMACHADO, LUCAS K.pt_BR
dc.contributor.authorZEITUNI, CARLOS A.pt_BR
dc.contributor.authorROSTELATO, MARIA E.C.M.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL NUCLEAR ATLANTIC CONFERENCEpt_BR
dc.date.accessioned2020-01-13T14:33:08Z
dc.date.available2020-01-13T14:33:08Z
dc.date.eventoOctober 21-25, 2019pt_BR
dc.description.abstractIn Brazil, it is estimated that for the biennium 2018 2019, that occurred 600 thousand of new cases of cancer for each year and lung cancer is the most common of all malignant tumors. Radiotherapy acts as a form of treatment from which come two basic modalities for the treatment of cancer: teletherapy and brachytherapy. In teletherapy is used a linear accelerator to make the application and before starting the treatment is carried out a planning that makes the acquisition of all anatomical information of the patient and then the classification of areas of interest in the patient. All planning prior to initiation undergoes a quality control dosimetry, which ensures that the dose prescribed in the planning will be delivered accurately in the treatment of the patient. In radiotherapy the dosimetry is applied as an independent measurement and this work has the objective of comparing the dosimetric plan of lung cancer in adjacent organs in this case the organ of risk is the heart with dose values calculated in the planning system (TPS) using an anthropomorphic phanton. All dosimetry was performed with thermo luminescent dosimeters (Lif: Mg,Ti TLD 100). We selected 50 TLDs that underwent a calibration process with thermal treatment, irradiation and reading. All the dosimeters passed through the reader in order to quantify its reading. The TLDs chosen were those that obtained coefficients of variation of less than 5% for three cycles of irradiation, in order to prove the methodology used for the thermal treatment, reading and calibration of dosimeters.pt_BR
dc.event.siglaINACpt_BR
dc.format.extent2797-2801pt_BR
dc.identifier.citationLUCCA, LUIZA V.G. de; RODRIGUES, BRUNA T.; SOUZA, PAULO R.D. de; MACHADO, LUCAS K.; ZEITUNI, CARLOS A.; ROSTELATO, MARIA E.C.M. Calibration methodology and selection of TLD – 100. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. <b>Proceedings...</b> Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 2797-2801. Disponível em: http://repositorio.ipen.br/handle/123456789/30654.
dc.identifier.orcid0000-0003-2943-6097pt_BR
dc.identifier.orcid0000-0002-7303-6720pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0003-2943-6097
dc.identifier.orcidhttps://orcid.org/0000-0002-7303-6720
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/30654
dc.localRio de Janeiropt_BR
dc.local.eventoSantos, SPpt_BR
dc.publisherAssociação Brasileira de Energia Nuclear
dc.rightsopenAccesspt_BR
dc.subjectcalibration
dc.subjectcobalt 70
dc.subjectcomparative evaluations
dc.subjectdosimetry
dc.subjectheat treatments
dc.subjectphantoms
dc.subjectplanning
dc.subjectradiotherapy
dc.subjectthermoluminescent dosemeters
dc.titleCalibration methodology and selection of TLD – 100pt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorPAULO ROBERTO DOMINGUES DE SOUZA
ipen.autorLUCAS KODATO MACHADO
ipen.autorMARIA ELISA CHUERY MARTINS ROSTELATO
ipen.autorCARLOS ALBERTO ZEITUNI
ipen.autorBRUNA TEIGA RODRIGUES
ipen.autorLUIZA VICENTINI GODOY DE LUCCA
ipen.codigoautor14444
ipen.codigoautor14819
ipen.codigoautor7
ipen.codigoautor944
ipen.codigoautor11600
ipen.codigoautor15006
ipen.contributor.ipenauthorPAULO ROBERTO DOMINGUES DE SOUZA
ipen.contributor.ipenauthorLUCAS KODATO MACHADO
ipen.contributor.ipenauthorMARIA ELISA CHUERY MARTINS ROSTELATO
ipen.contributor.ipenauthorCARLOS ALBERTO ZEITUNI
ipen.contributor.ipenauthorBRUNA TEIGA RODRIGUES
ipen.contributor.ipenauthorLUIZA VICENTINI GODOY DE LUCCA
ipen.date.recebimento20-01
ipen.event.datapadronizada2019pt_BR
ipen.identifier.ipendoc26303pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication4e7c8464-ab7d-41e9-a27c-d7314b53f441
relation.isAuthorOfPublication72982011-09eb-4b98-827b-25ba2f480527
relation.isAuthorOfPublicationda77b491-04ff-4c68-aa65-dead9208a48c
relation.isAuthorOfPublication02421b96-adef-4759-b25e-67d4759aa676
relation.isAuthorOfPublication3b25db9e-d05b-4fe0-b2a1-ab6b0c67d5ab
relation.isAuthorOfPublication49653929-3754-4201-b88d-ef613b5500f2
relation.isAuthorOfPublication.latestForDiscovery49653929-3754-4201-b88d-ef613b5500f2
sigepi.autor.atividadeROSTELATO, MARIA E.C.M.:7:230:Npt_BR
sigepi.autor.atividadeZEITUNI, CARLOS A.:944:230:Npt_BR
sigepi.autor.atividadeMACHADO, LUCAS K.:14819:230:Npt_BR
sigepi.autor.atividadeSOUZA, PAULO R.D. de:14444:230:Npt_BR
sigepi.autor.atividadeRODRIGUES, BRUNA T.:11600:230:Npt_BR
sigepi.autor.atividadeLUCCA, LUIZA V.G. de:15006:-1:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
26303.pdf
Tamanho:
485.99 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções