| dc.description.abstract | The interaction of lasers with the hard structures of the teeth, has found the excess of heat as a problem for its utilization. This study analyzes, in vitro, the interaction of the ultrashort pulse laser of Ti:safire (830 nm) with the bovine dental enamel. The system consisted in one main oscillator integrated with an amplifier (CPA). The pulses extracted before the temporal compression inside the amplifier had 30ps, 1000Hz and ~1mJ. The pulses extracted after the compression had 60fs, 1000Hz and ~0,7mJ. The M2 was 1,3, the focal lens 2,5 cm, the focal distance 29,7 and a computadorized translation stage x,y,z moved the sample. We evaluated the amount of tissue removed per pulse,the resulting cavities and the surrounding tissues not irradiated, under OM and SEM. The fluency was the major factor for differentiating the two regimens studied, therefore, the intensity was not so important as we expected in this process. We found: one ablation region in "cat tonge", one ablation length, one fluency ~0,7J/cm2 for 30ps and ~0,5J/cm2 for 60fs (50% ofhigh speed burr), smooth edge for 30ps and high precision of the shrp edge cut of submicrometric order for 60fs. | pt_BR |
| dc.format.extent | 91-91 | pt_BR |
| dc.identifier.citation | TODESCAN, C.D.R.; VIEIRA JUNIOR, N.D.; SAMAD, R.E.; FREITAS, A.Z.; EDUARDO, C.P. Ultrashort pulses over bovine dental enamel. <b>Brazilian Dental Journal</b>, v. 15, p. 91-91, 2004. Special issue. Disponível em: http://repositorio.ipen.br/handle/123456789/32759. | |
| dc.identifier.issn | 0103-6440 | pt_BR |
| dc.identifier.orcid | 0000-0002-5018-9126 | pt_BR |
| dc.identifier.orcid | 0000-0001-7762-8961 | pt_BR |
| dc.identifier.orcid | 0000-0003-0092-9357 | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0002-5018-9126 | |
| dc.identifier.orcid | https://orcid.org/0000-0001-7762-8961 | |
| dc.identifier.orcid | https://orcid.org/0000-0003-0092-9357 | |
| dc.identifier.percentilfi | Sem Percentil | pt_BR |
| dc.identifier.percentilfiCiteScore | Sem Percentil CiteScore | pt_BR |
| dc.identifier.suplemento | Special issue | pt_BR |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/32759 | |
| dc.identifier.vol | 15 | pt_BR |
| dc.relation.ispartof | Brazilian Dental Journal | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.source | International Congress on Laser in Dentistry, 9th, July 21-24, 2004, São Paulo, SP | pt_BR |
| dc.title | Ultrashort pulses over bovine dental enamel | pt_BR |
| dc.type | Resumos em periódicos | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | ANDERSON ZANARDI DE FREITAS | |
| ipen.autor | RICARDO ELGUL SAMAD | |
| ipen.autor | NILSON DIAS VIEIRA JUNIOR | |
| ipen.codigoautor | 880 | |
| ipen.codigoautor | 909 | |
| ipen.codigoautor | 1582 | |
| ipen.contributor.ipenauthor | ANDERSON ZANARDI DE FREITAS | |
| ipen.contributor.ipenauthor | RICARDO ELGUL SAMAD | |
| ipen.contributor.ipenauthor | NILSON DIAS VIEIRA JUNIOR | |
| ipen.date.recebimento | 22-02 | |
| ipen.identifier.fi | Sem F.I. | pt_BR |
| ipen.identifier.fiCiteScore | Sem CiteScore | pt_BR |
| ipen.identifier.ipendoc | 13002 | pt_BR |
| ipen.type.genre | Resumo | |
| relation.isAuthorOfPublication | a8d821f0-a0a4-4d52-b582-5c5d0afce8f5 | |
| relation.isAuthorOfPublication | b9c43c0c-87a6-4ebd-92ff-2515c4ac1d34 | |
| relation.isAuthorOfPublication | b5e4f489-bfb7-4e48-ae3a-eced2bb93a16 | |
| relation.isAuthorOfPublication.latestForDiscovery | b5e4f489-bfb7-4e48-ae3a-eced2bb93a16 | |
| sigepi.autor.atividade | FREITAS, A.Z.:880:920:N | pt_BR |
| sigepi.autor.atividade | SAMAD, R.E.:909:930:N | pt_BR |
| sigepi.autor.atividade | VIEIRA JUNIOR, N.D.:1582:930:N | pt_BR |