Development of an additional filtration system by 3D printing for the implementation of new X-ray beam qualities used in diagnostic radiology
| dc.contributor.author | ALMEIDA JR, J.N. de | pt_BR |
| dc.contributor.author | POTIENS, M.P.A. | pt_BR |
| dc.contributor.author | RODRIGUES JR, O. | pt_BR |
| dc.coverage | Internacional | pt_BR |
| dc.creator.evento | INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE | pt_BR |
| dc.date.accessioned | 2021-12-22T14:12:40Z | |
| dc.date.available | 2021-12-22T14:12:40Z | |
| dc.date.evento | November 29 - December 2, 2021 | pt_BR |
| dc.description.sponsorship | Comissão Nacional de Energia Nuclear (CNEN) | pt_BR |
| dc.description.sponsorshipID | CNEN: 01342.004839/2020-61 | pt_BR |
| dc.event.sigla | INAC | pt_BR |
| dc.identifier.citation | ALMEIDA JR, J.N. de; POTIENS, M.P.A.; RODRIGUES JR, O. Development of an additional filtration system by 3D printing for the implementation of new X-ray beam qualities used in diagnostic radiology. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, November 29 - December 2, 2021, Online. <b>Proceedings...</b> Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2021. Disponível em: http://repositorio.ipen.br/handle/123456789/32451. | |
| dc.identifier.orcid | 0000-0002-4049-6720 | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0002-6704-1910 | |
| dc.identifier.orcid | https://orcid.org/0000-0002-4049-6720 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/32451 | |
| dc.local | Rio de Janeiro | pt_BR |
| dc.local.evento | Online | pt_BR |
| dc.publisher | Associação Brasileira de Energia Nuclear | pt_BR |
| dc.rights | openAccess | pt_BR |
| dc.subject | 3d printing | |
| dc.subject | beams | |
| dc.subject | calibration | |
| dc.subject | diagnosis | |
| dc.subject | filtration | |
| dc.subject | quality control | |
| dc.subject | radiation metrology | |
| dc.subject | radiology | |
| dc.subject | x radiation | |
| dc.title | Development of an additional filtration system by 3D printing for the implementation of new X-ray beam qualities used in diagnostic radiology | pt_BR |
| dc.type | Texto completo de evento | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | ORLANDO RODRIGUES JUNIOR | |
| ipen.autor | MARIA DA PENHA ALBUQUERQUE POTIENS | |
| ipen.autor | JOSÉ NERES DE ALMEIDA JUNIOR | |
| ipen.codigoautor | 322 | |
| ipen.codigoautor | 346 | |
| ipen.codigoautor | 15400 | |
| ipen.contributor.ipenauthor | ORLANDO RODRIGUES JUNIOR | |
| ipen.contributor.ipenauthor | MARIA DA PENHA ALBUQUERQUE POTIENS | |
| ipen.contributor.ipenauthor | JOSÉ NERES DE ALMEIDA JUNIOR | |
| ipen.date.recebimento | 21-12 | |
| ipen.event.datapadronizada | 2021 | pt_BR |
| ipen.identifier.ipendoc | 28212 | pt_BR |
| ipen.notas.internas | Proceedings | pt_BR |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | f72d59d1-f942-442a-b16e-8b0ba0e2b671 | |
| relation.isAuthorOfPublication | 30f213ae-321d-4d51-8763-0a2585255fb9 | |
| relation.isAuthorOfPublication | 805c4e4c-809f-4952-924c-3cfdd0c4531f | |
| relation.isAuthorOfPublication.latestForDiscovery | 805c4e4c-809f-4952-924c-3cfdd0c4531f | |
| sigepi.autor.atividade | RODRIGUES JR, O.:322:330:N | pt_BR |
| sigepi.autor.atividade | POTIENS, M.P.A.:346:330:N | pt_BR |
| sigepi.autor.atividade | ALMEIDA JR, J.N. de:15400:330:S | pt_BR |