Statiscal differences and systematic effect on measurement procedure in thermoluminescent dosimetry of the iodine-125 brachytherapy seed

dc.contributor.authorZEITUNI, CARLOS A.pt_BR
dc.contributor.authorMOURA, EDUARDO S.pt_BR
dc.contributor.authorROSTELATO, MARIA E.C.M.pt_BR
dc.contributor.authorMANZOLI, JOSE E.pt_BR
dc.contributor.authorMOURA, JOAO A.pt_BR
dc.contributor.authorFEHER, ANSELMOpt_BR
dc.contributor.authorKARAM, DIBpt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1stpt_BR
dc.date.accessioned2014-11-17T17:07:15Zpt_BR
dc.date.accessioned2014-11-18T18:19:12Zpt_BR
dc.date.accessioned2015-04-02T02:00:18Z
dc.date.available2014-11-17T17:07:15Zpt_BR
dc.date.available2014-11-18T18:19:12Zpt_BR
dc.date.available2015-04-02T02:00:18Z
dc.date.eventoSeptember 27 - October 2, 2009pt_BR
dc.description.abstractIn order to provide the dosimetry for Iodine-125 seed production in Brazil, Harshaw thermoluminescent dosimeters (TLD-100) will be used. Even if measurements with TLD-100 of the same batch of fabrication are performed, the response will not be the same. As a consequence, they must be measured one by one. These dosimeters are LiF type with a micro-cube (1mm x 1mm x 1mm) shape. Irradiations were performed using Iodine-125 seeds to guarantee the same absorbed dose of 5 Gy in each dosimeter. It has been used a Solid Water Phantom with three concentrically circle with 20mm, 50mm and 70mm diameters. The angle of positions used was 0º, 30º, 60º and 90º. Of course there are 2 positions in 0º and 90º and 4 positions in 30º and 60º. These complete procedures were carried out five times in order to compare the data and minimize the systematic error. The iodine-125 seed used in the experiment was take off in each measure and put again turning his position 180º to guarantee the systematic error was minimized. This paper presents also a little discussion about the statistical difference in the measurement and the calculation procedure to determine the systematic error in these measurements.
dc.event.siglaINAC; ENAN; ENFIR; ENINpt_BR
dc.identifier.citationZEITUNI, CARLOS A.; MOURA, EDUARDO S.; ROSTELATO, MARIA E.C.M.; MANZOLI, JOSE E.; MOURA, JOAO A.; FEHER, ANSELMO; KARAM, DIB. Statiscal differences and systematic effect on measurement procedure in thermoluminescent dosimetry of the iodine-125 brachytherapy seed. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. <b>Proceedings...</b> Disponível em: http://repositorio.ipen.br/handle/123456789/12262.
dc.identifier.orcidhttps://orcid.org/0000-0002-5054-0799
dc.identifier.orcidhttps://orcid.org/0000-0003-2943-6097
dc.identifier.orcidhttps://orcid.org/0000-0002-7303-6720
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/12262pt_BR
dc.local.eventoRio de Janeiro, RJpt_BR
dc.publisherSao Paulo: ABEN, 2009pt_BR
dc.rightsopenAccesspt_BR
dc.subjectbrachytherapypt_BR
dc.subjectexperimental datapt_BR
dc.subjectiodine 125pt_BR
dc.subjectlithium fluoridespt_BR
dc.subjectphantomspt_BR
dc.subjectradiation dosespt_BR
dc.subjectradiation source implantspt_BR
dc.subjectthermoluminescent dosemeterspt_BR
dc.subjectthermoluminescent dosimetrypt_BR
dc.titleStatiscal differences and systematic effect on measurement procedure in thermoluminescent dosimetry of the iodine-125 brachytherapy seedpt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorJOÃO AUGUSTO MOURA
ipen.autorANSELMO FEHER
ipen.autorJOSE EDUARDO MANZOLI
ipen.autorMARIA ELISA CHUERY MARTINS ROSTELATO
ipen.autorEDUARDO SANTANA DE MOURA
ipen.autorCARLOS ALBERTO ZEITUNI
ipen.codigoautor6611
ipen.codigoautor786
ipen.codigoautor894
ipen.codigoautor7
ipen.codigoautor5860
ipen.codigoautor944
ipen.contributor.ipenauthorJOÃO AUGUSTO MOURA
ipen.contributor.ipenauthorANSELMO FEHER
ipen.contributor.ipenauthorJOSE EDUARDO MANZOLI
ipen.contributor.ipenauthorMARIA ELISA CHUERY MARTINS ROSTELATO
ipen.contributor.ipenauthorEDUARDO SANTANA DE MOURA
ipen.contributor.ipenauthorCARLOS ALBERTO ZEITUNI
ipen.date.recebimento09-10pt_BR
ipen.event.datapadronizada2009pt_BR
ipen.identifier.ipendoc15014pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication6a96a2fe-6eb6-488b-bd21-ac2b4e1335a3
relation.isAuthorOfPublication52268eaa-9747-4444-b301-7e33219b912c
relation.isAuthorOfPublication35d7d083-3831-41fa-bc4b-25dc5d902a9b
relation.isAuthorOfPublicationda77b491-04ff-4c68-aa65-dead9208a48c
relation.isAuthorOfPublicationfa668b29-92e1-43e8-b9db-5c151ab7d93d
relation.isAuthorOfPublication02421b96-adef-4759-b25e-67d4759aa676
relation.isAuthorOfPublication.latestForDiscovery02421b96-adef-4759-b25e-67d4759aa676
sigepi.autor.atividadeZEITUNI, CARLOS A.:944:230:Spt_BR
sigepi.autor.atividadeMOURA, EDUARDO S.:5860:230:Npt_BR
sigepi.autor.atividadeROSTELATO, MARIA E.C.M.:7:230:Npt_BR
sigepi.autor.atividadeMANZOLI, JOSE E.:894:220:Npt_BR
sigepi.autor.atividadeMOURA, JOAO A.:6611:230:Npt_BR
sigepi.autor.atividadeFEHER, ANSELMO:786:230:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
15014.pdf
Tamanho:
102.28 KB
Formato:
Adobe Portable Document Format

Coleções