Evaluation of the influence of the TH-GEM detector components in dosimetric measurements of standard mammography beams

dc.contributor.authorSILVA, NATALIA F.
dc.contributor.authorSILVA, TIAGO F.
dc.contributor.authorCASTRO, MAYSA C.
dc.contributor.authorCINTRA, FELIPE B.
dc.contributor.authorLUZ, HUGO N. da
dc.contributor.authorCALDAS, LINDA V.E.
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL NUCLEAR ATLANTIC CONFERENCEpt_BR
dc.date.accessioned2018-01-08T10:26:10Z
dc.date.available2018-01-08T10:26:10Z
dc.date.eventoOctober 22-27, 2017pt_BR
dc.description.abstractGEM detectors have found applications in many areas due to their simplicity of construction, low cost, ruggedness and diversity of shape. A dosimeter with these qualities presents utility in several applications, as for example in diagnostic and therapeutic medicine, industrial radiography and nuclear meters. Furthermore, the high sensitivity provided by GEM detectors may extend their applications in low dose dosimetry. Based on these facts, it may be interesting to produce a prototype of a portable TH-GEM type detector with characteristics suitable for dosimetric use in X-rays with low and medium energies. The precise determination of the dosimeter characteristics is very important for laboratories of instrument calibration, as well as to determine how the various components of the detector may influence on the energy deposited in the sensitive volume. In this work, the results obtained about the influence of each one of the components present in this type of detector in standard mammography beams is presented. The code MCNP5 was used. The results allowed the adaptation of the detector to the desired conditions.pt_BR
dc.event.siglaINACpt_BR
dc.identifier.citationSILVA, NATALIA F.; SILVA, TIAGO F.; CASTRO, MAYSA C.; CINTRA, FELIPE B.; LUZ, HUGO N. da; CALDAS, LINDA V.E. Evaluation of the influence of the TH-GEM detector components in dosimetric measurements of standard mammography beams. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. <b>Proceedings...</b> Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017. Disponível em: http://repositorio.ipen.br/handle/123456789/28231.
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/28231
dc.localRio de Janeiro, RJpt_BR
dc.local.eventoBelo Horizonte, MGpt_BR
dc.publisherAssociação Brasileira de Energia Nuclearpt_BR
dc.rightsopenAccesspt_BR
dc.subjectbeams
dc.subjectdosimetry
dc.subjectelectron multiplier detectors
dc.subjectmammary glands
dc.subjectmonte carlo method
dc.subjectrarefied gases
dc.subjectshielding
dc.subjectthickness
dc.subjectx radiation
dc.titleEvaluation of the influence of the TH-GEM detector components in dosimetric measurements of standard mammography beamspt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorFELIPE BELONSI DE CINTRA
ipen.autorLINDA V. E. CALDAS
ipen.autorMAYSA COSTA DE CASTRO
ipen.autorNATALIA FIORINI DA SILVA
ipen.codigoautor7952
ipen.codigoautor1495
ipen.codigoautor12105
ipen.codigoautor12139
ipen.contributor.ipenauthorFELIPE BELONSI DE CINTRA
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorMAYSA COSTA DE CASTRO
ipen.contributor.ipenauthorNATALIA FIORINI DA SILVA
ipen.date.recebimento18-01pt_BR
ipen.event.datapadronizada2017pt_BR
ipen.identifier.ipendoc24056pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication837c107d-deaa-4c92-87a2-49bd8d170150
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublicationa7ec93af-7e13-4572-8409-2fcafeab7015
relation.isAuthorOfPublicationc8a4b1ff-5955-47b9-a15a-ecbd12a4baa8
relation.isAuthorOfPublication.latestForDiscoveryc8a4b1ff-5955-47b9-a15a-ecbd12a4baa8
sigepi.autor.atividadeSILVA, NATALIA F.:12139:330:Spt_BR
sigepi.autor.atividadeCASTRO, MAYSA C.:12105:330:Npt_BR
sigepi.autor.atividadeCINTRA, FELIPE B.:7952:330:Npt_BR
sigepi.autor.atividadeCALDAS, LINDA V.E.:1495:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
24056.pdf
Tamanho:
441.76 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções