Corrosion analysis of a marked biomaterial

dc.contributor.authorPIERETTI, EURICO F.pt_BR
dc.contributor.authorNEVES, MAURICIO D.M. daspt_BR
dc.contributor.authorANTUNES, RENATO A.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoBRAZILIAN CONGRESS IN BIOMEDICAL ENGINEERING, 27thpt_BR
dc.date.accessioned2020-12-18T19:03:05Z
dc.date.available2020-12-18T19:03:05Z
dc.date.eventoOctober 26-30, 2020pt_BR
dc.description.abstractMarking is one of the last steps of manufacturing an implantable biomaterial. The marks on its surface constitute a permanent set of information in order to provide identification and traceability of the biomedical device. These markings become stress concentrators and regions with probability for the occurrence of failures that can lead to fracture; besides damaging the passive layer, naturally formed on stainless steels surfaces, favoring the beginning of several forms of degradation. This work presents the effect of two metal implant marking techniques on the corrosion resistance of ISO 5832-1 austenitic stainless steel, one of the most used surgical biomaterials used in Brazil. Engraving was carried out with mechanical and laser beam marking techniques were prepared. The electrochemical behavior was characterized by cyclic potentiodynamic polarization curves and indicate that the laser marking technique is the one that most affects the passive layer of the material when compared to the mechanical engraving.pt_BR
dc.event.siglaCBEBpt_BR
dc.format.extent1968-1973pt_BR
dc.identifier.citationPIERETTI, EURICO F.; NEVES, MAURICIO D.M. das; ANTUNES, RENATO A. Corrosion analysis of a marked biomaterial. In: BRAZILIAN CONGRESS IN BIOMEDICAL ENGINEERING, 27th, October 26-30, 2020, Vitória, ES. <b>Proceedings...</b> Rio de Janeiro, RJ: Sociedade Brasileira de Engenharia Biomédica, 2020. p. 1968-1973. Disponível em: http://200.136.52.105/handle/123456789/31683.
dc.identifier.orcid0000-0002-1304-2117pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-1304-2117
dc.identifier.urihttp://200.136.52.105/handle/123456789/31683
dc.localRio de Janeiro, RJpt_BR
dc.local.eventoVitória, ESpt_BR
dc.publisherSociedade Brasileira de Engenharia Biomédicapt_BR
dc.rightsopenAccesspt_BR
dc.subjectmedical supplies
dc.subjectcorrosion
dc.subjectchemical reactions
dc.subjectlasers
dc.subjectreliability
dc.subjectprostheses
dc.titleCorrosion analysis of a marked biomaterialpt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorEURICO FELIX PIERETTI
ipen.autorMAURICIO DAVID MARTINS DAS NEVES
ipen.codigoautor9762
ipen.codigoautor19
ipen.contributor.ipenauthorEURICO FELIX PIERETTI
ipen.contributor.ipenauthorMAURICIO DAVID MARTINS DAS NEVES
ipen.date.recebimento20-12
ipen.event.datapadronizada2020pt_BR
ipen.identifier.ipendoc27455pt_BR
ipen.notas.internasProceedingspt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication81bdc39e-9843-47fe-bbed-2ab1670d694a
relation.isAuthorOfPublication99e4f42a-cdfa-4da0-a1fc-4788ca55471c
relation.isAuthorOfPublication.latestForDiscovery81bdc39e-9843-47fe-bbed-2ab1670d694a
sigepi.autor.atividadeNEVES, MAURICIO D.M. das:19:-1:Npt_BR
sigepi.autor.atividadePIERETTI, EURICO F.:9762:-1:Spt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
27455.pdf
Tamanho:
548.24 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções