Quality assurance program for hand-foot contamination monitors

dc.contributor.authorALVAREZ, O.T.B.pt_BR
dc.contributor.authorCALDAS, L.V.E.pt_BR
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 11thpt_BR
dc.date.accessioned2014-11-17T18:33:46Zpt_BR
dc.date.accessioned2014-11-18T18:47:27Zpt_BR
dc.date.accessioned2015-04-01T22:17:32Z
dc.date.available2014-11-17T18:33:46Zpt_BR
dc.date.available2014-11-18T18:47:27Zpt_BR
dc.date.available2015-04-01T22:17:32Z
dc.date.evento23-28 May, 2004pt_BR
dc.description.abstractTo ensure that hand-foot contamination monitors meet the performance specifications of the manufacturers and comply with the standards of national and/or international radiation protection organizations, a quality assurance program (Q.A.) should be established. In this work, as a part of a Q.A, some quality control tests were developed and implanted following mainly a Brazilian standard (NBR-12604) and a British guidance (HS(G)49). The procedures were applied to an Eurisys/Sirius hand-foot contamination monitor. The following tests were performed: measurement of the response uniformity for alpha and/or beta contamination, measurement of instrument linearity, checks on beta rejection characteristics, periodical movement of the detector covering Mylar sheet and cleaning of the feet windows, teaching of staff members for good use of the instrument, and weekly controls of the background count rates. Each time sources were needed, circular and rectangular flat sources of Am-241 and Cl-36 were used.
dc.event.siglaIRPApt_BR
dc.identifier.citationALVAREZ, O.T.B.; CALDAS, L.V.E. Quality assurance program for hand-foot contamination monitors. In: INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 11th, 23-28 May, 2004, Madrid, Spain. Disponível em: http://repositorio.ipen.br/handle/123456789/17533.
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/17533pt_BR
dc.local.eventoMadrid, Spainpt_BR
dc.rightsopenAccesspt_BR
dc.subjectcontaminationpt_BR
dc.subjecthandspt_BR
dc.subjectfeetpt_BR
dc.subjectradiation monitoringpt_BR
dc.subjectradiation dosespt_BR
dc.subjectradiation detectorspt_BR
dc.subjectcalibrationpt_BR
dc.subjectmonitorspt_BR
dc.subjectquality assurancept_BR
dc.titleQuality assurance program for hand-foot contamination monitorspt_BR
dc.typeTexto completo de eventopt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.autorOSCAR TEODULO BORDON ALVAREZ
ipen.codigoautor1495
ipen.codigoautor2002
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorOSCAR TEODULO BORDON ALVAREZ
ipen.date.recebimento05-10pt_BR
ipen.event.datapadronizada2004pt_BR
ipen.identifier.ipendoc10809pt_BR
ipen.type.genreArtigo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublication72cd1df3-a918-45fc-8a76-07a92b8350f7
relation.isAuthorOfPublication.latestForDiscovery72cd1df3-a918-45fc-8a76-07a92b8350f7
sigepi.autor.atividadeALVAREZ, O.T.B.:2002:28:Spt_BR
sigepi.autor.atividadeCALDAS, L.V.E.:1495:28:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
10809.pdf
Tamanho:
78.41 KB
Formato:
Adobe Portable Document Format

Coleções